Preferred Language
Articles
/
joe-1901
Numerical Simulation of the Thermal Performance of a Tubular Solar Air Heater
...Show More Authors

In this work, a flat-plate solar air heater (FSAH) and a tubular solar air heater (TSAH) were designed and tested numerically. The work investigates the effect of increasing the contact area between the flowing air and the absorber surface of each heater and predicts the expected results before the fabrication of the experimental rig. Three-dimensional two models were designed and simulated by the ANSYS-FLUENT 16 Program. The solar irradiation and ambient air temperature were measured experimentally on December 1st 2022, at the weather conditions of Baghdad City- Iraq, at three air mass flow rates, 0.012 kg/s, 0.032 kg/s, and 0.052 kg/s. The numerical results showed the advantage in the thermal performance of the TSAH in comparison to the FSAH, represented by better air temperature difference, better heat transfer from the absorber to air, and better thermal efficiency. The TSAH has a higher thermal efficiency than the FSAH by 7 %, 19 % °C, and 22 % at 0.012 kg/s, 0.032 kg/s, and 0.052 kg/s, respectively. The improvement of the thermal characteristics of the TSAH can be referred to as the increment in the heat transfer contact area between the absorber and the flowing air.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
A proposed program to audit the performance of the hotel sector under crises (Applied Research)
...Show More Authors

Abstract:

        The research sought to identify the crises that occurred during the research period and their reflection on the performance of the hotel Research sample as well as to identify the reality of auditing the hotel Research sample and the preparation of a performance audit program can be adopted in auditing the performance of hotels in light of crises, and the problem of the research lies in the lack of a program to audit the performance of hotels that takes into account the crises experienced by the hotel sector, The research was based on solving its problems on three hypotheses, the first is that the performance audit in light of the Covid-19 pand

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Study Of Factors Affecting The Thermal Conductivity Of Iraqi Bentonite
...Show More Authors

Thermal conductivity of compacted bentonite is one of the most important properties where this type of clay is proposed for use as a buffer material. In this study, Lee's disc method was used to measure the thermal conductivity of compacted bentonite specimens. The experimental results have been analyzed to observe the three major factors affecting the thermal conductivity of bentonite buffer material. While the clay density reaches to a target value, the measurement is taken to evaluate the thermal conductivity. By repeating this procedure, a relationship between clay dry density and thermal conductivity has been established in specimens after adjusting the water contents of the bentonite by placing its specimens in a drying oven for diffe

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Lecture Notes In Electrical Engineering
A Study of the Influence of Steel Brushes in Rail Surface Magnetic Flux Leakage Detection Using Finite Elements Simulation
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
Modeling and Simulation of Copper Removal from the Contaminated Soil by a Combination of Adsorption and Electro-kinetic Remediation
...Show More Authors

Electro-kinetic remediation technology is one of the developing technologies that offer great promise for the cleanup of soils contaminated with heavy metals. A numerical model was formulated to simulate copper (Cu) transport under an electric field using one-dimensional diffusion-advection equations describing the contaminant transport driven by chemical and electrical gradients in soil during the electro-kinetic remediation as a function of time and space. This model included complex physicochemical factors affecting the transport phenomena, such as soil pH value, aqueous phase reaction, adsorption, and precipitation. One-dimensional finitedifference computer program successfully predicted meaningful values for soil pH profiles and Cu

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Oct 20 2021
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Design and Evaluation of Polygonal Trough Solar Concentrator
...Show More Authors

     In this paper, a solar concentrator is designed in the form of a concave half-cylindrical mirror consisting of polygonal reflective surface plates. The plates are arranged to give a hemispherical shape to the design. These surfaces work to receive solar radiation and focusing by reflecting it to the receiver that is placed in front of the reflecting surfaces. The results are compared with a system consisting of a concave reflecting surface of the same dimensions to obtain a good criterion for evaluating the design performance. The results showed a low acceptance angle for the design for all the samples used due to the geometrical design nature. The optical efficiency affected by the angle of incidence greatly by

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Effect of Air Bubbles on Heat Transfer Coefficient in Turbulent Convection Flow
...Show More Authors

Experimental and numerical studies have been conducted for the effect of injected air bubbles on the heat transfer coefficient through the water flow in a vertical pipe under the influence of uniform heat flux. The investigated parameters were water flow rate of (10, 14 and 18) lit/min, air flow rate of (1.5, 3 and 4) lit/min for subjected heat fluxes of (27264, 36316 and 45398) W/m2. The energy, momentum and continuity equations were solved numerically to describe the motion of flow. Turbulence models k-ε was implemented. The mathematical model is using a CFD code Fluent (Ansys15). The water was used as continuous phase while the air was represented as dispersed. phase. The experimental work includes design, build and instrument a test

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Engineering
The Improvement of Thermal Insulating Concrete Panel
...Show More Authors

The Iraqi houses flattening the roof by a concrete panel, and because of the panels on the top directly exposed to the solar radiation become unbearably hot and cold during the summer and winter. The traditional concrete panel components are cement, sand, and aggregate, which have a poor thermal property. The usage of materials with low thermal conductivity with no negative reflects on its mechanical properties gives good improvements to the thermal properties of the concrete panel. The practical part of this work was built on a multi-stage mixing plan. In the first stage the mixing ratio based on the ratios of the sand to cement. The second stage mixing ratios based on replacing the coarse aggregate quantities with the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Journal Of The College Of Education For Women
The Properties of Thermal Waves Affecting Iraq
...Show More Authors

This research aims at studying each of the cold and hot thermal wavelengths affecting
Iraq for a minimum climatic course of 11 years beginning from 1992 till 2002. Three stations
were selected including the parts of Iraq surface: Mosul, Baghdad and Basrah.
The wave days were also connected with the related climatic elements represented by
the wind direction and speeds and the relative humidity. It was shown that Iraq is affected by
the rates of hot thermal wave lengths greatly compared to the rates of cold wavelengths. The
results suggested that the highest rate of hot and cold wavelengths recorded over Basra station
was (3.5) days for the cold and (5) days for the hot. While the lowest rates was at Mosul
station

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Solving Nonlinear COVID-19 Mathematical Model Using a Reliable Numerical Method
...Show More Authors

This research aims to numerically solve a nonlinear initial value problem presented as a system of ordinary differential equations. Our focus is on epidemiological systems in particular. The accurate numerical method that is the Runge-Kutta method of order four has been used to solve this problem that is represented in the epidemic model. The COVID-19 mathematical epidemic model in Iraq from 2020 to the next years is the application under study. Finally, the results obtained for the COVID-19 model have been discussed tabular and graphically. The spread of the COVID-19 pandemic can be observed via the behavior of the different stages of the model that approximates the behavior of actual the COVID-19 epidemic in Iraq. In our study, the COV

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri May 01 2020
Journal Name
International Journal Of Psychosocial Rehabilitation
Building and codifying a scale of the level of tactical performance of advanced volleyball players
...Show More Authors

The research objectives, to build a measure of the level of tactical performance of volleyball players applying for the Iraqi Premier League for the 2018-2019 season. The nature of the research problem, then the researchers determined the research sample in the deliberate manner of the players of the Iraqi clubs for the Premier League (B, A). The researchers adopted the entire community as a sample for the research, and the number (156) players distributed over (13) clubs and divided the sample into (12)players an exploratory experiment player representing (the police club) and (100) player representing the construction sample and after a maximum period of two months has passed since applying the scale to the construction sample the researc

... Show More
Preview PDF