The laser micro-cutting process is the most widely commonly applied machining process which can be applied to practically all metallic and non-metallic materials. While this had challenges in cutting quality criteria such as geometrical precision, surface quality and numerous others. This article investigates the laser micro-cutting of PEEK composite material using nano-fiber laser, due to their significant importunity and efficiency of laser in various manufacturing processes. Design of experiential tool based on Response Surface Methodology (RSM)-Central Composite Design (CCD) used to generate the statistical model. This method was employed to analysis the influence of parameters including laser speed, laser power, laser frequency and number of passes on the cutting characteristics -and geometrical. Cutting-geometry requirements are significant quality features since they are one of the metrics for the geometrical precision of micro-cutting proses it was concluded that higher laser power, slower speed, and more pass number result in a low kerf taper, these parameters have a significant impact on the other cutting characteristics, and geometrical. Whereas the frequency has the lowers impact on the cutting geometrical. Finally, the experiments show Maximum depth was 2000, width minimum top kerf width was 305.56 µm and the minimum angle of 2.8906.
Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl
... Show MoreIn the present work, radium (226Ra), thorium (232Th), potassium (40 K), and cesium (137Cs) (Bq/kg) was measured for 24 soil samples of some districts of Al-Doura city in Baghdad governorate. The gamma spectrometry method with NaI (Tl) detector was used for radiometric measurements. The average values of specific activity for 226Ra, 232Th, 40K and 137Cs in soil samples were 38.03, 42.48, 16.34 and 2.76 Bq/kg, respectively. The radiation indicators were measured and the average values recorded were 100 Bq/kg, 44.6 nGy/h, 0.27 Bq/kg, 0.373 Bq/kg, 0.219 mSv/y, 0.055 mSv/y and 0.689 Bq/kg for the parameters of radium equivalent act
... Show More
Abstract
Praise be to Allah, The Lord of the worlds, and peace be upon
Muhammad the master of former and latter people, and peace be upon His
relatives, companions and those who followed Him to Judgment day.
After recognizing the prescription which is called (Al- Fadhaly's Thesis in
parsing of "There is no god but God") as it is related with the word of the
investigation of this issue attracted me, as being related with the idea of the
only one God that is mentioned in the prophetic speech, which is said by
Anas- God satisfies him- Who said, Said the Messenger Muhammad peace
be upon him " Goes out of the Hell who said: there is no god but God, and in
his heart a hair weight of charity, and goes out of the He
This study aimed to identify the employment of the social networking platform «Twitter» in the 2016 presidential campaign led by the Republican candidate, Donald Trump; and analyse his tweets through his personal account on «Twitter» for the period from: 10/ 8/2016 to: 11/ 8/2016 which represents the last month of the election campaign.
The study belongs to the type of descriptive studies using the analytical method through an analysis index that includes sub-categories and other secondary categories. The research has adopted the ordinary unit of information material (tweet) as an analysis unit for this purpose.
... Show MoreCo(II) ion was determined by a new, accurate, sensitive and rapid method via a
continuous flow injection analysis (CFIA) with a chemiluminescence reaction based on
the oxidation of Luminol which is loaded on poly acrylic acid gel beads by hydrogen
peroxide in presence of Cobalt (II) ion as a chemiluminescence catalyst. Chemical and
physical parameters were investigated to obtain the best conditions. Linear dynamic
range of Cobalt (II) ion was from 0.1-20.0 μg.ml-1 with a correlation coefficient r =
0.9758, limit of detection (L.O.D) 0.2 ng/sample from the step wise dilution of lowest
concentration in the calibration graph with the percentage relative standard deviation for
3 μg.ml-1 Co(ll) solution is 0.8537% (n
This study was conducted to determine the ability of water treatment system (Vortisand) to reduce some chemical and physical properties for tigris river raw water, It consisted of turbidity, electrical conductivity, pH, total hardness, calcium Hardness as well as temperature in order to determine the unit`s efficiency for reducing their concentration as compared to those in the water produced by some classical potable water projects (Dora and Wathba) in Baghdad. Samples were collected during the cold months (December 2016 and January 2017) and during the hot months (May and June 2017). The results showed that this system has the ability to reduce some properties such as turbidity, the values were 215NTU in raw water and decreased to NTU
... Show MoreA new ligand [ 2-chloro-N- (1,5-dimethyl-3-oxo-2-phenyl-2,3-dihydro -1H-pyrazol- 4-ylcarbamothioyl)acetamide](L) was synthesized by reacting the Chloro acetyl isothiocyanate with 4-aminoantipyrine,The ligand was characterized by(C HNS) elemental microanalysis and the spectral measurements including Uv-Vis ,IR ,1H and13C NMR spectra, some transition metals complex of this ligand were prepared and characterized by Uv-Vis, FT-IR spectra, conductivity measurements, magnetic susceptibility and atomic absorption. From the obtained results the molecular formula of all prepared complexes were [M(L)2(H2O)2]Cl2 (M+2 =Mn, Co, Ni, Cu, Zn, Cd and Hg),the proposed geometrical structure for all complexes were octahedral.
A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the
... Show More