Preferred Language
Articles
/
joe-1837
Comparative Reliability Analysis between Horizontal-Vertical-Diagonal Code and Code with Crosstalk Avoidance and Error Correction for NoC Interconnects
...Show More Authors

Ensuring reliable data transmission in Network on Chip (NoC) is one of the most challenging tasks, especially in noisy environments. As crosstalk, interference, and radiation were increased with manufacturers' increasing tendency to reduce the area, increase the frequencies, and reduce the voltages.  So many Error Control Codes (ECC) were proposed with different error detection and correction capacities and various degrees of complexity. Code with Crosstalk Avoidance and Error Correction (CCAEC) for network-on-chip interconnects uses simple parity check bits as the main technique to get high error correction capacity. Per this work, this coding scheme corrects up to 12 random errors, representing a high correction capacity compared with many other code schemes. This candidate has high correction capability but with a high codeword size. In this work, the CCAEC code is compared to another well-known code scheme called Horizontal-Vertical-Diagonal (HVD) error detecting and correcting code through reliability analysis by deriving a new accurate mathematical model for the probability of residual error Pres for both code schemes and confirming it by simulation results for both schemes. The results showed that the HVD code could correct all single, double, and triple errors and failed to correct only 3.3 % of states of quadric errors. In comparison, the CCAEC code can correct a single error and fails in 1.5%, 7.2%, and 16.4% cases of double, triple, and quadric errors, respectively. As a result, the HVD has better reliability than CCAEC and has lower overhead; making it a promising coding scheme to handle the reliability issues for NoC.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon May 15 2023
Journal Name
Iraqi Journal Of Science
In Vivo Effect of Catharanthus roseus Crude Extracts on Pathogenic Bacteria Isolated from Skin infections
...Show More Authors

This study includes collection of 70 swabs samples of burns from patients were
admitted in three hospitals (Baghdad, Al- Numaan and burns injuries Hospital). All
swabs samples were cultured on blood and MacConkey agar media to isolate and
identify pathogenic bacteria according to their morphological , biochemical and
growth characters. Growth of bacteria on selective media showed the following
results: Pseudomonas aeroginosa 44.28% , Klebsiella pneumonia 30% ,
Staphylococcu saureus 8.57% , Escherichia coli 4.28% , Proteus vulgaris 4.28 % ,
Enterobacter spp. 5.71% , Acinetobacter baumanni 2.89 %. Different concentrations
were prepared from leaves ethanolic crude extract of Catharanthus roseus , then the
anti-bac

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 19 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Use of Logistic Regression Approach to Determine the Effective Factors Causing Renal Failure Disease
...Show More Authors

    The main goal of this research is to determine the impact of some variables that we believe that they are important to cause renal failuredisease by using logistic regression approach.The study includes eight explanatory variables and the response variable represented by (Infected,uninfected).The statistical program SPSS is used to proform the required calculations

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Feb 02 2022
Journal Name
Iraqi Journal Of Science
Subsurface Investigation of Merjan oil field Depending on 3D Seismic Reflection Central Iraq
...Show More Authors

The study deals with 3D seismic reflection in the central Iraq within Merjan oil field which is located approximately (130 km) to the southwest Baghdad and south of Razaza. The 3D seismic survey was interpreted; the results showed that the oil is found within Hartha Formation as stratigraphic traps and with the absence of structural traps. The major normal faults picked are trending N-S direction. There are also minor faults observed using the instantaneous phase and frequency sections, they proved the presence of the faults and showed that the ending of the Safawi reflector toward the north and northeast to the south and southeast and near the western border of fault because of the facies change in the area. The reflector shows a struct

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 01 2024
Journal Name
Latin American Journal Of Pharmacy
The protective effect of iraqi Juniperus oxycedrus plant on acute kidney injury induced by lipopolysaccharide in mice model
...Show More Authors

Inflammatory control is essential to diminish injury and make renal injury treatment simpler. Proposed therapeutics have primarily targeted pro-inflammatory variables. Juniperus oxycedrus was frequently used to treat a variety of infectious disorders, hyperglycemia, obesity, TB, bronchitis, inflammation, and pneumonia. Juniperus oxycedrus twigs and leaves were defatted with n-hexane using Soxhlet apparatus then the residue of plant material dried and re-extracted sequentially by two different solvents Ethylacetate and methanol. The pro-inflammatory markers IL-1 and iNOS, as well as the potential kidney biomarker KIM-1, TNF-α, and transcription factor NF-KB were measured using the RealTime Quantitative qPCR method. The results showed that J

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Engineering
Microbicidal Effect of Fe2O3 Nanoparticles in Antimicrobial Agent System
...Show More Authors

Microbial antibiotics resistance is considered a serious health issue in the Middle East and developing countries. In this study, the Fe2O3 nanoparticles was prepared chemically, and the particles size and shape were analyzed by using Scan electron microscope (SEM) and X-Ray diffraction (XRD). Different concentration of Fe2O3 nanoparticles were used and examined on E.coli and S. aureus. Using liquid dilution and in vitro cytotoxicity assay by microplate toxicity test (MTT). The microbial cell metabolic activity was measured on gram-negative, gram-positive bacteria and fungi after treating with different concentrations of Fe2O3 nanoparticl

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 12 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Acute Toxicity of Rutin in Mice
...Show More Authors

Acute toxicity is a step to evaluate the toxicity of a substance. Rutin is one of the flavonoid compounds with a variety of pharmacological effects. The aim of the study is to calculate the lethal dose that affect fifty percent of the mice used in the experiment (LD50). Thirty Swiss albino male and 30 non-pregnant female mice have been divided equally and randomly into 5 treated groups and one control group (n=5)  Rutin has been administered with  concentrations 5, 2.5.1.25,0.625 and 0.312 g/kg administered as a single dose intraperitoneally (IP) while the control group received 1% DMSO (IP).  Animals were observed for any morbidity and mortality for 14 days. After 14 days the animal blood collected for biochemical and hem

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Mon Oct 28 2019
Journal Name
Iraqi Journal Of Science
Exploration of A Cemetery Using Ground Penetration Radar
...Show More Authors

     Ground penetrating radar (GPR) technology is used to determine the extent to which this technique can detect with a high-frequency range from 10 MHz to 1000 MHz into the ground by a transmitting antenna and A graveyard was found beneath the depth of the three meters under Surface of the earth in the shrine of the Prophet Houd and Saleh in Al-Najaf Governorate surveyed by through 4 tracks. Ground Penetrating Radar (GPR) is a device that transmits short pulses of electromagnetic energy with pulse duration about 1 ns to 20 ns. applying the filter Time- Zero to the same profile at a depth (3m) , Two types of antennas were used in this study, with two different frequencies antennas (250, 500 )MHz Three tracks (23,25,2

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Apr 27 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
S-Coprime Submodules
...Show More Authors

  In this paper, we introduce and study the concept of S-coprime submodules, where a proper submodule N of an R-module M is called S-coprime submodule if M N is S-coprime Rmodule. Many properties about this concept are investigated.

View Publication Preview PDF
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Notes on Approximately Pure Submodules
...Show More Authors

Let R be a commutative ring with identity 1 and M be a unitary left R-module. A submodule N of an R-module M is said to be approximately pure submodule of an R-module, if for each ideal I of R. The main purpose of this paper is to study the properties of the following concepts: approximately pure essentialsubmodules, approximately pure closedsubmodules and relative approximately pure complement submodules. We prove that: when an R-module M is an approximately purely extending modules and N be Ap-puresubmodulein M, if M has the Ap-pure intersection property then N is Ap purely extending.

View Publication Preview PDF
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
A Impact of High Voltage Direct Current Link on Transmission Line in Kurdistan Power System
...Show More Authors

Kurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.

View Publication Preview PDF
Crossref (1)
Crossref