Preferred Language
Articles
/
joe-1783
Experimental Evaluation of PV Panel Efficiency Using Evaporative Cooling Integrated with Water Spraying
...Show More Authors

In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1, the evaporative cooling decreased the temperature of the PV panel by about 15 ℃ related to the uncooled PV panel for both pad thicknesses. While case #2 showed a more significant temperature drop for PV panel by about 27 ℃  and 29.7 ℃ for pad thicknesses of 5 cm and 10 cm, respectively. Compared to the uncooled PV panel, the cooled panel had a distinct enhancement in performance. The efficiency of the PV panel in case #1 was augmented by 5.7% with 50 mm pad thickness and 8.4% for 100 mm pad thickness. Case #2 revealed more improvement in the efficiency by 9% for 5 cm and up to 20% for 10 cm pad thickness. The PV panel electric power was augmented by 7.3% and 13.8% for 2 and 3 lpm water flow rates, respectively. Compared to the flow rate of 1 lpm. The open voltage circuit improved by 4.1% and 9.4% for cases #1 and #2, respectively. The higher air temperature drop was about 11.4 ℃ for case #2 at 10 cm pad thickness.

 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon May 04 2020
Journal Name
Environmental Engineering Research
Experimental and modeling study of water defluoridation using waste granular brick in a continuous up-flow fixed bed
...Show More Authors

Contamination of surface and groundwater with excessive concentrations of fluoride is of significant health hazard. Adsorption of fluoride onto waste materials of no economic value could be a potential approach for the treatment of fluoride-bearing water. This experimental and modeling study was devoted to investigate for the first the fluoride removal using unmodified waste granular brick (WGB) in a fixed bed running in continuous mode. Characterization of WGB was carried out by FT-IR, SEM, and EDX analysis. The batch mode experiments showed that they were affected by several parameters including contact time, initial pH, and sorbent dosage. The best values of these parameters that provided maximum removal percent (82%) with the in

... Show More
Scopus (19)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Wed Jul 05 2017
Journal Name
Https://www.researchgate.net/journal/international-journal-of-science-and-research-ijsr-2319-7064
Evaluation of Water Quality using Bhargava Water Quality Index Method and GIS, Case Study: Euphrates River in Al-Najaf City
...Show More Authors

ENGLISH

Crossref (4)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
International Journal Of Agricultural And Statistical Sciences
Effect of foliar spraying with gibberellic and humic acid on wheat growth
...Show More Authors

Scopus (11)
Scopus
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Engineering
Experimental Evaluation of the Strut-and-Tie Model Applied to Deep Beam with Near-Load Openings
...Show More Authors

It is commonly known that Euler-Bernoulli’s thin beam theorem is not applicable whenever a nonlinear distribution of strain/stress occurs, such as in deep beams, or the stress distribution is discontinuous. In order to design the members experiencing such distorted stress regions, the Strut-and-Tie Model (STM) could be utilized. In this paper, experimental investigation of STM technique for three identical small-scale deep beams was conducted. The beams were simply supported and loaded statically with a concentrated load at the mid span of the beams. These deep beams had two symmetrical openings near the application point of loading. Both the deep beam, where the stress distribution cannot be assumed linear, and the ex

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Heat Transfer
A tubular solar still integrated with a heat pipe
...Show More Authors
Abstract<p>The aim of this work is to explore the thermal performance of a tracked tubular solar still (TSS) with a parabolic trough concentrator in Baghdad (33.27° N, 44.37° E) in September 2022. The present tubular still is distinguished by its hexagonal glass cover. The effect of integrating the TSS with a heat pipe, the still tilt angle (10°, 15°), and the depth of saline water inside the still partitions on the productivity of freshwater are investigated. The results showed that using heat pipe enhances the freshwater productivity by 25%–40% and the efficiency by 25%. For the still integrated with heat pipe, as the water depth is increased from 5.5 to 6.5 cm the productivity of freshwater is incre</p> ... Show More
View Publication
Scopus (16)
Crossref (8)
Scopus Crossref
Publication Date
Mon Jun 30 2025
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Enhanced oil recovery (EOR) by ionic liquid assisted with low salinity water: Experimental study in carbonate rock
...Show More Authors

   There is a growing imperative to extract oil not only through primary and secondary means but also via tertiary recovery methods to meet the escalating global energy demands. Consequently, Enhanced Oil Recovery (EOR) is slated to increase significance in the oil industry in the coming years. The amalgamation of low salinity water (LSW) with chemicals to augment oil recovery has gained substantial traction in recent years owing to its demonstrated effectiveness. In this study, a systematic investigation utilizing contact angle measurements to elucidate the underlying mechanisms was undertaken. The results reveal that the contact angle (CA) demonstrated the effectiveness of the combined fluid in altering the wettability from oil-

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Fri May 31 2019
Journal Name
Journal Of Engineering
Water Retention Techniques under Crop’s Root Zone a Tool to Enhance Water Use Efficiency and Economic Water Productivity for Zucchini
...Show More Authors

 A new technique in cultivation by installing membrane sheet below the crop’s root zone was helped to save irrigation water in the root zone, less farm losses, increasing the field water use efficiency and water productivity. In this paper, the membrane sheet was installed below the root zone of zucchini during the summer growing season 2017 in open field.  This research was carried out in a private field in Babil governorate at Sadat Al Hindiya Township reached 72 km from Baghdad. Surface trickle irrigation system was used for irrigation process. Two treatment plots were used, treatment plot T1 using membrane sheet and treatment plot T2 without using the membrane sheet. The applied irrigation water, time of

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Mar 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying the Performance of Refrigeration Units Powered by Solar Panel
...Show More Authors

An experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.

View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Iraqi Journal Of Physics
Stand-Alone PV Generator Comparing with Conventional Systems for Electrification of Small Social Centres in Remote Area
...Show More Authors

Many isolated rural communities are located in regions where there is an abundant and reliable supply of solar energy, but where the distance to the nearest power station is many tens or even hundreds of kilometre. It is therefore mainly in these areas that rural electrification is now being provided by PV generators. since Stand-Alone PV generator can offer the most cost-effective and reliable option for providing power needed in remote places. Accordingly these isolated rural canters are fitted with PV for lighting, a refrigerator, a television and socket to supply kitchen appliances

View Publication Preview PDF
Publication Date
Wed Jun 30 2021
Journal Name
International Journal Of Intelligent Engineering And Systems
Promising Gains of 5G Networks with Enhancing Energy Efficiency Using Improved Linear Precoding Schemes
...Show More Authors

Scopus (2)
Scopus Crossref