Preferred Language
Articles
/
joe-1755
Comparative Study of Water Desalination using Reverse Osmosis (RO) and Electro-dialysis Systems (ED): Review
...Show More Authors

The increasing drinking water demand in many countries leads to an increase in the use of desalination plants, which are considered a great solution for water treatment processes. Reverse osmosis (RO) and electro-dialysis (ED) systems are the most popular membrane processes used to desalinate water at high salinity. Both systems work by separating the ionic contaminates and disposing of them as a brine solution, but ED uses electrical current as a driving force while RO uses osmotic pressure. A direct comparison of reverse osmosis and electro-dialysis systems is needed to highlight process development similarities and variances. This work aims to provide an overview of previous studies on reverse osmosis and electro-dialysis systems related to membrane module and design processes; energy consumption; cost analysis; operational problems; efficiency of saline removal; and environmental impacts of brine disposal. RO system uses osmotic pressure as a driving force to force water through the membrane with less energy than other desalination systems. The enhancements in membrane materials and power recovery of the unit have massively decreased the price of RO units. ED system uses an electrical current to push dissolved ions across ion exchange membranes. The results of this review showed that desalination plants must be integrated with renewable energy to reduce power consumption and costs related to energy. Various technologies, including treatment processes and disposal methods, must be used to control concentrated solutions resulting from desalination processes because 5 to 33% of the total cost of the desalination process is associated with brine disposal.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 24 2025
Journal Name
Plos One
Assessment of the bypass of obturation materials beyond fractured instruments after using different obturation techniques in simulated curved canals (An in-vitro study)
...Show More Authors

This study evaluated the extent to which obturation materials bypass fractured endodontic instruments positioned in the middle and apical thirds of severely curved simulated root canals using different obturation techniques. Sixty resin blocks with simulated root canals were used, each with a 50° curvature, a 6.5 mm radius of curvature, and a length of 16.5 mm, prepared to an ISO #15 diameter and taper. Canals were shaped using ProTaper Universal files (Dentsply Maillefer) attached to an X-smart Plus endo motor (Dentsply), set at 3.5 Ncm torque and 250 rpm, up to size S2 at working length. To simulate fractures, F2 and F3 files were weakened 3 mm from the tip, then twisted to break in the apical and middle sections of the canal, re

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
Application of the Holonic Manufacturing System using the Genetic Algorithm : Case Study in Lab 7 of the General Company for the Leather Industry
...Show More Authors

The study aims to achieve several objectives, including follow-up scientific developments and transformations in the modern concepts of the Holistic Manufacturing System for the purpose of identifying the methods of switching to the entrances of artificial intelligence, and clarifying the mechanism of operation of the genetic algorithm under the Holonic Manufacturing System, to benefit from the advantages of systems and to achieve the maximum savings in time and cost of machines Using the Holistic Manufacturing System method and the Genetic algorithm, which allows for optimal maintenance time and minimizing the total cost, which in turn enables the workers of these machines to control the vacations in th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri May 02 2014
Journal Name
International Journal Of Scientific & Technology Research
Synthesis, Structure And Characterization Of Zns Qds And Using It In Photocatalytic Reaction
...Show More Authors

ZnS nanoparticles were prepared by a simple microwave irradiation method under mild condition. The starting materials for the synthesis of ZnS quantum dots were zinc acetate (R & M Chemical) as zinc source, thioacetamide as a sulfur source and ethylene glycol as a solvent. All chemicals were analytical grade products and used without further purification. The quantum dots of ZnS with cubic structure were characterized by X-ray powder diffraction (XRD), the morphology of the film is seen by scanning electron microscopy (SEM). The particle size is determined by field effect scanning electron microscopy (FESEM), UV-Visible absorption spectroscopy and XRD. UV-Visible absorption spectroscopy analysis shows that the absorption peak of the as-prep

... Show More
Publication Date
Thu Jul 05 2018
Journal Name
Eurasip Journal On Wireless Communications And Networking
Positioning and guiding educational robots by using fingerprints of WiFi and RFID array
...Show More Authors

View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Sep 22 2025
Journal Name
International Journal Of Technology
Numerical Investigations of SiO2 and TiO2 Nanoparticle's Addition Impact on Performance, Combustion Features, and Emission Characteristics of a Diesel Engine Operating with Water Diesel Emulsified Fuel at Different Lambda Values and Engine Speeds
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro the Effect of Canals Instrumented with Three Rotary Ni-Ti Systems on the Dislocation Resistanceo Guttafusion ® versus Single Cone Obturation Technique
...Show More Authors

Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randomly i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 01 2020
Journal Name
International Journal Of Pharmaceutical Research
Effectiveness of Self-Instructional Strategy and the Traditional Teaching Approach on Nursing Students' Knowledge toward Cardiopulmonary Resuscitation at the College of Nursing in University of Baghdad: Randomized Comparative Trial
...Show More Authors

MM ABDUL-WAHHAB, SA AHMED, International Journal of Pharmaceutical Research, 2020 - Cited by 2

View Publication Preview PDF
Publication Date
Wed Apr 01 2020
Journal Name
Plant Archives
Effect of alternate water quality irrigation on pore sizes distribution during drainage in clay loam texture soil
...Show More Authors

Scopus (2)
Scopus
Publication Date
Mon Dec 30 2024
Journal Name
Water, Air, & Soil Pollution
Design of New Wet Heterogeneous Photo Oxidation Process for Refinery Waste Water Treatment in Photo Baffled Reactor
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The Use of Tea leaves Wastes to reduce Hexavalent Chromium Concentration in industrial Waste Water by Adsorption
...Show More Authors

Abstract : A research was conducted to study the process parameters affecting hexavalent chromium Cr (VI) (carcinogenic compound) the removal percentage from the electrical industries company waste water that contain 88 mg/l of Cr (VI) concentration by adsorption onto tea wastes. Synthetic water with 88 mg/l Cr (VI) concentration was used. Several operation parameters affecting Cr (VI) removal efficiency were investigated, such as pH, initial Cr (VI) concentration, stirring time and tea wastes dose. The experimental results reveal that maximum Cr (VI) removal reached up to 94.26% at pH of 2, stirring time of 180 minute, tea wastes do

... Show More
View Publication Preview PDF
Crossref