Preferred Language
Articles
/
joe-1755
Comparative Study of Water Desalination using Reverse Osmosis (RO) and Electro-dialysis Systems (ED): Review
...Show More Authors

The increasing drinking water demand in many countries leads to an increase in the use of desalination plants, which are considered a great solution for water treatment processes. Reverse osmosis (RO) and electro-dialysis (ED) systems are the most popular membrane processes used to desalinate water at high salinity. Both systems work by separating the ionic contaminates and disposing of them as a brine solution, but ED uses electrical current as a driving force while RO uses osmotic pressure. A direct comparison of reverse osmosis and electro-dialysis systems is needed to highlight process development similarities and variances. This work aims to provide an overview of previous studies on reverse osmosis and electro-dialysis systems related to membrane module and design processes; energy consumption; cost analysis; operational problems; efficiency of saline removal; and environmental impacts of brine disposal. RO system uses osmotic pressure as a driving force to force water through the membrane with less energy than other desalination systems. The enhancements in membrane materials and power recovery of the unit have massively decreased the price of RO units. ED system uses an electrical current to push dissolved ions across ion exchange membranes. The results of this review showed that desalination plants must be integrated with renewable energy to reduce power consumption and costs related to energy. Various technologies, including treatment processes and disposal methods, must be used to control concentrated solutions resulting from desalination processes because 5 to 33% of the total cost of the desalination process is associated with brine disposal.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jul 06 2021
Journal Name
Journal Of Ecological Engineering
Chromium Elimination from Contaminated Soil by Electro kinetic Remediation, Using Garlic Peels Powder
...Show More Authors

View Publication
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Mar 30 2018
Journal Name
International Journal Of Science And Research
The Effect of Age 0nLeptin Hormone and Some Biochemical Parameters in Patients Pre-Dialysis
...Show More Authors

To evaluate impact the difference in stages ofage and related incidence of hemodialysis patients.Two hundred and fifty patients undergoing hemodialysis were collected from general hospital in Baghdad city /Iraq. The samples with renal failure before hemodialysis were divided into (138) male,( 112)female. The sera were separated from samples to physiological investigation. We found that renal failure was more predominant among the patients ages group ranging from (51-70) years old. The results shows A significant increase in the levels of urea, creatinine, in younger patients (≤ 30 years) when compared with older patients (>70 years). Furthermore a significant decrease in serum levels of total protein in patients in older patients (>7

... Show More
Publication Date
Wed Jun 14 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ATTITUDE OF OFFICIALS IN THE INDUSTRIAL COMPANY TOWARDS THE PRACTICE OF REVERSE/ AN APPLIED STUDY IN BAGHDAD COMPANY FOR SOFT DRINKS.: ATTITUDE OF OFFICIALS IN THE INDUSTRIAL COMPANY TOWARDS THE PRACTICE OF REVERSE/ AN APPLIED STUDY IN BAGHDAD COMPANY FOR SOFT DRINKS.
...Show More Authors

This paper deals with the subject of demarcating as appropriate scientific techniques to rationalize consumption and to control segments of the society for the technical conduct of its handling of the product depending on the mix of elements (product and the volume of demand, Price, promotion and distribution), but inverse manner designed to adjust the working condition of balance between supply and demand and to ensure that rates continue in the marketing process properly, and therefore the research aims to shed light on some of the practices that reflect the Demarketing techniques, As well as the statement of the reality of attitudes towards the practice of those techniques through a sample survey of officials in Baghdad company for so

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Phosphorus Removal from Water and Waste Water by Chemical Precipitation Using Alum and Calcium Chloride
...Show More Authors

Phosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.
The dosage of calcium chloride and pH of solution play an importa

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Improvement of the Water Use Efficiency and Yield of Eggplant by Using Subsurface Water Retention Technology
...Show More Authors

Sustainable crop production in a coarse soil texture is challenging due to high water permeability and low soil water holding capacity. In this paper, subsurface water retention technology (SWRT) through impermeable polyethylene membranes was placed at depth 35 cm below ground surface and within the root zone to evaluate and compare the impact of these membranes and control treatment (without using the membranes) on yield and water use efficiency of eggplant inside the greenhouse. The study was conducted in Al-Fahamah Township, Baghdad, Iraq during spring growing season 2017. Results demonstrated the yield and water use efficiencies were 3.483 kg/m2 and 5.653 kg/m3, respectively for SWRT treatment p

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Water, Air, & Soil Pollution
Decontamination of Cobalt-Polluted Soils Using an Enhanced Electro-kinetic Method, Employing Eco-friendly Conditions
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Removal of COD from Petroleum refinery Wastewater by Electro-Coagulation Process Using SS/Al electrodes
...Show More Authors
Abstract<p>In the present study, the effectiveness of a procedure of electrocoagulation for removing chemical oxygen demand (COD) from the wastewater of petroleum refinery has been evaluated. Aluminum and stainless steel electrodes were used as a sacrificial anode and cathode respectively. The effect of current density (4-20mAcm<sup>−2</sup>), pH (3-11), and NaCl concentration (0-4g/l) on efficiency of removal of chemical oxygen demand was investigated. The results have shown that increasing of current density led to increase the efficiency of COD removal while increasing NaCl concentration resulted in decreasing of COD removal efficiency. Effect of pH was found to be lowering COD re</p> ... Show More
View Publication
Scopus (36)
Crossref (21)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
2nd International Conference On Engineering &amp; Science
Comparative on-grid solar systems winter performance analyses of different PV technologies in Baghdad weather
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Oct 05 2015
Journal Name
Diyala Journal For Pure Science
Determination of zinc ions in drinking water distribution systems (PVC pipes) by spectrophotometric method
...Show More Authors

In this work, a method for the simultaneous spectrophotometric determination of zinc which was precipitated into deionized water that is in a commercial distribution systems PVC pipe, is proposed using UV-VIS Spectrophotometer. The method based on the reaction between the analytes Zn2+ and 2-carboxy-2-hyroxy-5-sulfoformazylbenze (Zincon) at an absorption maximum of 620nm at pH 9-10. This ligand is selective reagent. Since the complex is colored (blue), its stoichiometry can be established using visible spectrometry to measure the absorbance of solutions of known composition. The stoichiometry of the complex was determined by Job’s method and molar ratio method and found to be 1:2 (M: L). A series of synthetic solution containing different

... Show More
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
Emergency Messages Dissemination Challenges Through Connected Vehicles for Efficient Intelligent Transportation Systems: A Review
...Show More Authors

Recent growth in transport and wireless communication technologies has aided the evolution of Intelligent Transportation Systems (ITS). The ITS is based on different types of transportation modes like road, rail, ocean and aviation. Vehicular ad hoc network (VANET) is a technology that considers moving vehicles as nodes in a network to create a wireless communication network. VANET has emerged as a resourceful approach to enhance the road safety. Road safety has become a critical issue in recent years. Emergency incidents such as accidents, heavy traffic and road damages are the main causes of the inefficiency of the traffic flow. These occurrences do not only create the congestion on the road but also increase the fuel consumption and p

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref