Preferred Language
Articles
/
joe-1733
A Modified Vigenère Cipher based on Time and Biometrics features
...Show More Authors

Biometrics is widely used with security systems nowadays; each biometric modality can be useful and has distinctive properties that provide uniqueness and ambiguity for security systems especially in communication and network technologies. This paper is about using biometric features of fingerprint, which is called (minutiae) to cipher a text message and ensure safe arrival of data at receiver end. The classical cryptosystems (Caesar, Vigenère, etc.) became obsolete methods for encryption because of the high-performance machines which focusing on repetition of the key in their attacks to break the cipher. Several Researchers of cryptography give efforts to modify and develop Vigenère cipher by enhancing its weaknesses. The proposed method uses local feature of fingerprint represented by minutiae positions to overcome the problem of repeated key to perform encryption and decryption of a text message, where, the message will be ciphered by a modified Vigenère method. Unlike the old usual method, the key constructed from fingerprint minutiae depend on instantaneous date and time of ciphertext generation. The Vigenère table consist of 95 elements: case sensitive letters, numbers, symbols and punctuation.  The simulation results (with MATLAB 2021b) show that the original message cannot be reconstructed without the presence of the key which is a function of the date and time of generation. Where 720 different keys can be generated per day which mean 1440 distinct ciphertexts can be obtained for the same message daily.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Ieee Transactions On Neural Systems And Rehabilitation Engineering
A Framework of Temporal-Spatial Descriptors-Based Feature Extraction for Improved Myoelectric Pattern Recognition
...Show More Authors

View Publication
Scopus (134)
Crossref (134)
Scopus Clarivate Crossref
Publication Date
Mon May 27 2019
Journal Name
Al-khwarizmi Engineering Journal
Investigation the Influence of SPIF Parameters on Residual Stresses for Angular Surfaces Based on Iso-Planar Tool Path
...Show More Authors

Incremental Sheet Metal Forming (ISMF) is a modern sheet metal forming technology which offers the possibility of manufacturing 3D complex parts of thin sheet metals using the CNC milling machine. The surface quality is a very important aspect in any manufacturing process. Therefore, this study focuses on the resultant residual stresses by forming parameters, namely; (tool shape, step over, feed rate, and slope angle) using Taguchi method for the products formed by single point incremental forming process (SPIF). For evaluating the surface quality, practical experiments to produce pyramid like shape have been implemented on aluminum sheets (AA1050) for thickness (0.9) mm. Three types of tool shape used in this work, the spherical tool ga

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Periodicals Of Engineering And Natural Sciences
Bayesian and non-Bayesian estimation of the lomax model based on upper record values under weighted LINEX loss function
...Show More Authors

In this article, we developed a new loss function, as the simplification of linear exponential loss function (LINEX) by weighting LINEX function. We derive a scale parameter, reliability and the hazard functions in accordance with upper record values of the Lomax distribution (LD). To study a small sample behavior performance of the proposed loss function using a Monte Carlo simulation, we make a comparison among maximum likelihood estimator, Bayesian estimator by means of LINEX loss function and Bayesian estimator using square error loss (SE) function. The consequences have shown that a modified method is the finest for valuing a scale parameter, reliability and hazard functions.

View Publication
Scopus (9)
Scopus
Publication Date
Tue Feb 14 2023
Journal Name
Journal Of Educational And Psychological Researches
The Effect of Educational Program Based on the (Guttmann) Model for Developing Awareness and Emotional Experience among University Students
...Show More Authors

Abstract

The aim of the research is to identify the level of awareness and emotional experience among university students and to identify the effect of the educational program based on (Guttmann) model for developing awareness and emotional experience among university students by verifying the validity of the following zero hypotheses: 1) There are no statistically significant differences in the development of awareness and emotional experience among university students at the level of (0.05) between the mean scores of the experimental group in the pre and post-tests. 2) There are no statistically significant differences in the development of awareness and emotional experience among university students at the lev

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 18 2021
Journal Name
International Journal Of Emerging Technologies In Learning (ijet)
The Effectiveness of Educational Pillars Based on Vygotsky's Theory in Achievement and Information Processing Among First Intermediate Class Students
...Show More Authors

The aim of the research is to identify the effectiveness of the educational pillars strategy based on Vygotsky's theory in mathematical achievement and information processing of first-grade intermediate students. In pursuit of the research objectives, the experimental method was used, and the quasi-experimental design was used for two equivalent groups, one control group taught traditionally and the other experi-mental taught according to the educational pillars strategy. The research sample consisted of (66) female students from the first intermediate grade, who were inten-tionally chosen after ensuring their equivalence, taking into account several factors, most notably chronological age and their level of mathematics, and they we

... Show More
View Publication
Crossref (4)
Crossref
Publication Date
Wed May 15 2024
Journal Name
Ieee Sensors Journal
Surface Crack Size Estimation Based on Quantification and Decoupling of Magnetic Flux Leakage (MFL) Signals of Circular Array Sensors
...Show More Authors

View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Oct 22 2020
Journal Name
2020 4th International Symposium On Multidisciplinary Studies And Innovative Technologies (ismsit)
Artificial Intelligence in Smart Agriculture: Modified Evolutionary Optimization Approach for Plant Disease Identification
...Show More Authors

View Publication
Scopus (10)
Crossref (9)
Scopus Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Ain Shams Engineering Journal
Improving the rutting resistance of asphalt pavement modified with the carbon nanotubes additive
...Show More Authors

Scopus (45)
Crossref (42)
Scopus Clarivate Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Jacc: Cardiovascular Interventions
CRT-500.20 Barriers and Motivators for Participation of Cardiovascular Healthcare Providers in Clinical Trials in Iraq: A Survey-Based Study
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Thu Dec 05 2024
Journal Name
Shifaa
Evaluating alveolar bone thickness in upper and lower incisors from orthodontic perspective. A Cone beam computed tomography-based retrospective study
...Show More Authors

Purpose: This study aimed to assess the thickness of alveolar bone of maxillary and mandibular incisors from orthodontics perspective. Materials and Method: A total of 73 Cone beam computed tomography for Iraqi patients (47 females and 26 males) were included in this study. The selected images were captured and imported to AutoCAD database software to perform the measurement. To measure alveolar bone thickness, a reference line was drawn through the long axis of each incisor, from the incisal edge to the root apex. Then, labial and lingual/palatal perpendicular lines were drawn to the reference line at 3, 6, and 9mm apically from the cemento-enamel junction (CEJ). Results: The buccal bone is generally thinner than the lingual/palata

... Show More
View Publication
Crossref (5)
Crossref