Preferred Language
Articles
/
joe-1717
Flexural Behavior of Reinforced Rubberized Reactive Powder Concrete Beams under Repeated Loads
...Show More Authors

Non-biodegradability of rubber tires contributes to pollution and fire hazards in the natural environment. In this study, the flexural behavior of the Rubberized Reactive Powder Concrete (RRPC) beams that contained various proportions and sizes of scrap tire rubber was investigated and compared to the flexural behavior of the regular RPC. Fresh properties, hardened properties, load-deflection relation, first crack load, ultimate load, and crack width are studied and analyzed. Mixes were made using micro steel fiber of the straight type, and they had an aspect ratio of 65. Thirteen beams were tested under two loading points (Repeated loading) with small-scale beams (1100 mm, 150 mm, 100 mm) size.

The fine aggregate is replaced by 5, 10, and 15%, respectively, with crumb rubber. While replacement of silica fume was 10, 20, 30, and 50%, respectively, with very fine rubber. Also, chip rubber was added to the mixture as coarse aggregate with 5, 10, and 15%. Five tested beams were chosen as case studies to analyze and compare the results of the ABAQUS software with the experimental results. The results showed that the flexural behavior of RRPC beams that contains rubber was acceptable when compared with the flexural behavior of the RPC beam (depending on load-carrying capacity). The crack width was decreased by including waste rubber and steel fibers. There is a satisfactory agreement between the results of the numerical analysis and the results of the experimental testing. Slight ultimate load differences are targeted between the effects of the monotonic loading and the repeated loading.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Engineering
The Improvement of Thermal Insulating Concrete Panel
...Show More Authors

The Iraqi houses flattening the roof by a concrete panel, and because of the panels on the top directly exposed to the solar radiation become unbearably hot and cold during the summer and winter. The traditional concrete panel components are cement, sand, and aggregate, which have a poor thermal property. The usage of materials with low thermal conductivity with no negative reflects on its mechanical properties gives good improvements to the thermal properties of the concrete panel. The practical part of this work was built on a multi-stage mixing plan. In the first stage the mixing ratio based on the ratios of the sand to cement. The second stage mixing ratios based on replacing the coarse aggregate quantities with the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Nov 03 2021
Journal Name
Journal Of Engineering Research
Performance of quadrilateral perforated prestressed concrete rafters
...Show More Authors

This study focuses on the behavior of simply supported perforated prestressed concrete rafters (PPCRs) under single midspan monotonic static loading. The experimental program consisted of testing seven specimens; one solid (control) rafter, and six perforated with quadrilateral openings. The main investigated variables are the number and height of the openings. The test findings indicate that, in comparison to the solid rafter, the presence of quadrilateral openings in the PPCRs led to reducing the load capacity by (4.3-36%) and increase the midspan deflection at ultimate by (14.8-33%). Also, increasing the number of concrete posts between openings resulted in increasing the failure load and decreasing the deflection at all stages o

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Corrosion-Resistance Characteristics of Concrete Containing Furfural
...Show More Authors

Corrosion inhibiting admixtures are unique among other methods to protect reinforced concrete from corrosion damage. In this study, the effect of furfural on the fresh and hardened properties of concrete mixes of 35 and 45 MPa compressive strengths as well as the corrosion inhibition of furfural was evaluated. Furfural was added at different dosages (1, 2 and 3% by weight of cement) with and without superplasticizer (HRWR). Different electrochemical measurements were performed (Half-cell potential, Tafel plot and linear polarization resistance). Electrochemical measurements confirmed that furfural dramatically reduces the rate of corrosion; the inhibition efficiencies were 62.7 and 63.8 % due to 3% furfural addition to 35 and 45MPa-concr

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Some Durability Test of No-Fine Concrete
...Show More Authors

In this study, two types of mixes were adopted by using two grading of coarse aggregate. The practical side of this study was to produce no-fine aggregate concrete by using crushed clay brick aggregates. The durability of the produced concrete and internal sulfate attack was studied.      For durability assessment, it is found that the no-fine concrete made with crushed brick aggregate lost about (15-25) % of its compressive strength after being subjected to 60 cycles of wetting and drying with age 120 days. The curing condition showed that the water curing improved the compressive strength with a rate higher than that when sealed or air dry curing were used. The crushed brick no-fine concrete de

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 01 2015
Journal Name
Journal Of Environmental Engineering
Using Granular Dead Anaerobic Sludge as Permeable Reactive Barrier for Remediation of Groundwater Contaminated with Phenol
...Show More Authors

Scopus (21)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Iraqi Journal Of Applied Physics
Spectral and Electrical Characteristics of Nanostructured NiO/TiO 2 Heterojunction Fabricated by DC Reactive Magnetron Sputtering
...Show More Authors

In this work, p-n junctions were fabricated from highly-pure nanostructured NiO and TiO2 thin films deposited on glass substrates by dc reactive magnetron sputtering technique. The structural characterization showed that the prepared multilayer NiO/TiO2 thin film structures were highly pure as no traces for other compounds than NiO and TiO2 were observed. It was found that the absorption of NiO-on-TiO2 structure is higher than that of the TiO2-on-NiO. Also, the NiO/TiO2 heterojunctions exhibit typical electrical characteristics, higher ideality factor and better spectral responsivity when compared to those fabricated from the same materials by the same technique and with larger particle size and lower structural purity.

View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Annals Of Parasitology
Serum levels of C-reactive protein and ferritin in COVID-19 patients infected with Toxoplasma gondii
...Show More Authors

During infection, T. gondii disseminates by the circulatory system and establishes chronic infection in several organs. Almost third of humans, immunosuppressed individuals such as HIV/AIDS patients, cancer patients, and organ transplant recipients are exposed to toxoplasmosis. Therefore, the study aimed to investigate the possibility that Toxoplasma infection could be a risk factor for COVID-19 patients and its possible correlation with C-reactive protein and ferritin. Overall 220 patients referred to the Al Furat General Hospital, Baghdad, Iraq were enrolled from 2020–2021. All serum samples were tested for T. gondii immunoglobulins (IgG and IgM) antibodies, C-reactive protein and ferritin levels. In patients with COVID-19, the results

... Show More
Scopus (3)
Scopus
Publication Date
Sat Feb 01 2020
Journal Name
Journal Of Water Process Engineering
Waterworks sludge-filter sand permeable reactive barrier for removal of toxic lead ions from contaminated groundwater
...Show More Authors

Scopus (214)
Crossref (192)
Scopus Clarivate Crossref
Publication Date
Tue Jan 29 2019
Journal Name
Journal Of The College Of Education For Women
Grammatical terminology under the criticism microscope
...Show More Authors

this research five grammatical terminology, and predicate and ascribed to it and added and genitive, examined scientific accuracy envisaged in placed and how they conform to the content then proposed five alternative terminology, and proved that this alternative terminology reflects more accurately the content of conventional terminology in Arabic grammar lesson, logical approach relies on analysis of morphological derivation of the term and its language, and recommended research to pursue critical studies in grammatical terminology, because such research has Significant impact in removing the grammatical ambiguity of some scholars, as well as instrumental in the development of methods of teaching Arabic grammar, to return to the relatio

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Inguinal hernia repair under local anaesthesia
...Show More Authors

Background: For various reasons, inguinal hernia repair under local anaesthesia is not well accepted to both patients and surgeons. The patients fear from pain and surgeons need full relaxation and co-operation to do successful hernia repairMethods: purpose of this study is to evaluate the effectiveness of local anaesthesia in inguinal hernia repair.prospective study was made from January 2011-0ctober 2013 , on a total of 50 patients with inguinal hernia operated on under local anaesthesia. Patients were selected primarily on the basis of their willingness to accept the procedure after the technique was described to them.Results: In this study 50 patient and 58 herniorrhaphies done for them during a period of about 34months were evaluate

... Show More
View Publication Preview PDF