Water is an essential aspect of life and important in evolution. Recently the potable water quality topic has received much attention. The study aims to determine drinking water quality in Al-Najaf City by collecting samples throughout Al-Najaf city and comparing the results with the Iraqi guidelines (IQS 417) and World Health Organization (WHO) guidelines, as well as to calculate the WQI. Samples were tested in the laboratory between December 2021 and June 2022. The results showed that multiple parameters exceeded the allowable limits during both testing periods; during winter months, the results of TDS and turbidity exceeded the upper limits in multiple locations. Total hardness values also exceeded the limit of 500 ppm for all samples taken in the winter period. For magnesium and calcium, summer measurements were mainly within limits, unlike winter period measurements which mostly exceeded the limits. Residual chlorine tests in winter had higher concentrations, generally ranging from 0.25 to 0.8 mg/l. While During summer, concentrations dropped below the allowable limit in multiple sampling points. The study concluded that the majority of the water samples gathered during the winter months were of poor quality as the total WQI values were between (99-110), While the total WQI values for water samples collected during the summer period were rated as good quality water ranged between (75-81).
The present article delves into the examination of groundwater quality, based on WQI, for drinking purposes in Baghdad City. Further, for carrying out the investigation, the data was collected from the Ministry of Water Resources of Baghdad, which represents water samples drawn from 114 wells in Al-Karkh and Al-Rusafa sides of Baghdad city. With the aim of further determining WQI, four water parameters such as (i) pH, (ii) Chloride (Cl), (iii) Sulfate (SO4), and (iv) Total dissolved solids (TDS), were taken into consideration. According to the computed WQI, the distribution of the groundwater samples, with respect to their quality classes such as excellent, good, poor, very poor and unfit for human drinking purpose, was found to be
... Show MoreThis paper investigated in the numerical simulation model to calculate the Earth magnetic field components at north provinces of Najaf city (Longitude 44.316 o -44.3592o E and Latitude 32.0508o - 32.0256o N). The components of the Earth magnetic field (total intensity (F), horizontal intensity (H), declination (D), inclination (I), the north component(X), the east component(Y), and Down component(Z)) were found by using spherical harmonic world magnetic model (WMM2010). A great deal of anomaly has been discovered in all components of the Earth magnetic field at the selected region (Long. 44.345o-44.335o E, Lat.32.042o-32.032o N) using Kriging method.
... Show MoreInterpreting is a process adopted by a skillful and well qualified interpreter to convey orally the meaning from a source language into a target language simultaneously .In this process the interpreter has no time to think or check the exact meaning of the words, phrases and sentences. The main technique used by the interpreter is based on his/her competence .This type of translation is used in press conferences and political speeches of high rank figures.
This paper deals with analyzing the interpretation of Obama's farewell speech adopted by two authentic TV Channels(Sky News and AL- Jazeera).The aim of this paper is to investigate the quality of each interpreting by adopting Nida's (1996:164
... Show MoreThe removal of turbidity from produced water by chemical coagulation/flocculation method using locally available coagulants was investigated. Aluminum sulfate (alum) is selected as a primary coagulant, while calcium hydroxide (lime) is used as a coagulant aid. The performance of these coagulants was studied through jar test by comparing turbidity removal at different coagulant/ coagulants aid ratio, coagulant dose, water pH, and sedimentation time. In addition, an attempt has been made to examine the relationship between turbidity (NTU) and total suspended solids (mg/L) on the same samples of produced water. The best conditions for turbidity removal can be obtained at 75% alum+25% lime coagulant at coagulant dose of 80 m
... Show MoreMost of drinking water consuming all over the world has been treated at the water treatment plant (WTP) where raw water is abstracted from reservoirs and rivers. The turbidity removal efficiency is very important to supply safe drinking water. This study is focusing on the use of multiple linear regression (MLR) and artificial neural network (ANN) models to predict the turbidity removal efficiency of Al-Wahda WTP in Baghdad city. The measured physico-chemical parameters were used to determine their effect on turbidity removal efficiency in various processes. The suitable formulation of the ANN model is examined throughout many preparations, trials, and steps of evaluation. The predict
Sustainable crop production in a coarse soil texture is challenging due to high water permeability and low soil water holding capacity. In this paper, subsurface water retention technology (SWRT) through impermeable polyethylene membranes was placed at depth 35 cm below ground surface and within the root zone to evaluate and compare the impact of these membranes and control treatment (without using the membranes) on yield and water use efficiency of eggplant inside the greenhouse. The study was conducted in Al-Fahamah Township, Baghdad, Iraq during spring growing season 2017. Results demonstrated the yield and water use efficiencies were 3.483 kg/m2 and 5.653 kg/m3, respectively for SWRT treatment p
... Show MoreThe aim of this investigation was to study the impact of various reaction parameters on wastewater taken from Al-Wathba water treatment plant on Tigris River in south of Baghdad, Iraq with sodium hypochlorite solution. The parameters studied were sodium hypochlorite dose, contact time, initial fecal coliform bacteria concentration, temperature, and pH. In a batch reactor, different concentrations of sodium hypochlorite solution were used to disinfect 1L of water. The amount of hypochlorite ions in disinfected water was measured using an Iodimetry test for different reaction times, whereas the Most Probable Number (MPN) test was used to determine the concentration of coliform bacteria. Total Plate Count (TPC) was utilized in this study to
... Show MoreEvaluation was carried out on the existing furrow irrigation system located in an open agricultural field within Hor Rajabh Township, south of Baghdad, Iraq (latitude: 33°09’ N, longitude: 44°24’ E). Two plots were chosen for comparison: treatment plot T1, which used subsurface water retention technology (SWRT) with a furrow irrigation system. While the treatment plot T2 was done by using a furrow irrigation procedure without SWRT. A comparison between the two treatment plots was carried out to study the efficiency of the applied water on crop yield. In terms of agricultural productivity and water use efficiency, plot T1 outperformed plot T2, according to the study’s final fin
During a period of two years, from January 1995 till December 1996, the first survey on fish parasites in Bahr Al-Najaf depression, mid Iraq, was achieved. A total of 6992 fishes, belonging to 11 species, were collected and inspected for external and internal parasites. These fishes were infected with three protozoans (Ichthyophthirius multifiliis, Trichodina domerguei and Myxobolus pfeifferi), two monogeneans (Dactylogyrus cornu and Gyrodactylus elegans), two digenetic trematodes (Clinostomum complanatum and Ascocotyle coleostoma), one nematode (Contracaecum sp.) and one acanthocephalan (Neoechinorhynchus iraqensis). Five fish species were recorded as new h
... Show MoreSource, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators