Preferred Language
Articles
/
joe-161
Galvanic Corrosion of Carbon Steel -Stainless Steel Couple in Sulfuric Acid under Flow Conditions
...Show More Authors

Galvanic corrosion of stainless steel 316 (SS316) and carbon steel (CS) coupled in 5% wt/v sulfuric acid solution at agitation velocity was investigated. The galvanic behavior of coupled metals was also studied using zero resistance ammeter (ZRA) method. The effects of agitation velocity, temperature, and time on galvanic corrosion current and loss in weight of both metals in both free corrosion and galvanic corrosion were investigated. The trends of open circuit potential (OCP) of each metal and galvanic potential (Eg) of the couple were, also, determined. Results showed that SS316 was cathodic relative to CS in galvanic couple and its OCP was much more positive than that of CS for all investigated ranges of operating conditions. A sharp increase in galvanic current from CS to SS316 was noticed in the first 20 min and then decrease with time. Increasing the agitation velocity led to increase in galvanic corrosion rate. The decrease in galvanic current is attributed to metal passivation due to the formation of a protective film which grows with time. The minus sign in galvanic current means that the current is flow from CS (anode) to SS316 (cathode). The galvanic current of CS-SS316 couple shifts to the negative direction with increase agitation velocity.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technology
Effect of Vertical Irregularity in Multi-Storied Building under Seismic Loading
...Show More Authors

Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
A study of the safety and security conditions followed in the X-ray clinics in the Al-Amiriya-Baghdad
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Gas Flow Formation in the Inertial Filtering (IF) Gas Separators Curvilinear Channels
...Show More Authors

This paper deals with an up to date problem for oil and gas industry- separation of the gas -fluid fogs. Here is described the worked out physical model of the gas movement process in the sections of the inertial filtering (IF) gas separators. One can find the mathematical model for research of the fields of velocities and pressures in the inertial curvilinear channel. The main simplifications and assumptions are explained. This mathematical model has been made using mathematical program Maple and it is received the 3-d graphic of the distribution componential speed parts in the channel and also 2-d graphics at the channel sectional view when the flow is flat. The new method for gas - fluid systems separation is suggested.

View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Iraqi Journal Of Physics
Fabrication of carbon nanopowder by arc discharge technique
...Show More Authors

Carbon Nanopowder was fabricated by arc discharge technique at deposition pressure of 10-5 mbar Argon gas on glass substrates. The prepared carbon nano- powder was collected from chamber and purified with nitric acid at 323K .The morphology and crystalline structure of the prepared powder was examined by X-Ray Diffraction (XRD), Atomic Force Microscope (AFM), and Scanning Electron Microscope (SEM). XRD spectrums showed that the powder exhibits amorphous structure and after purification, the powder showed hexagonal structure with a preferential orientation along(002) direction ,where AFM and SEM gave very compatible estimation on the grain size and shape of the nanopowder.

View Publication Preview PDF
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Diffusion kinetics of Furfural adsorption onto Activated Carbon
...Show More Authors

A range of batch experiments were carried out for the estimation of the key process parameters in adsorption of Furfural from aqueous solution onto activated carbon in fixed-bed adsorber. A batch absorber model has been used to determine the external mass transfer coefficient (kf) which equal to 6.24*10-5 m/s and diffusion coefficient (Dp) which equal to 9.875*10-10 m2/s for the Furfural system. The Langmuir model gave the best fit for the data at constant temperature (30oC). The pore diffusion mathematical model using nonlinear isotherm provides a good description of the adsorption of Furfural onto activated carbon.

View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Development A Method For Production Of Carbon Nanotubes
...Show More Authors

In this work chemical vapor deposition method (CVD) for the production of carbon nanotubes (CNTs) have been improved by the addition of S. Steel mesh container (SSMC) inside which the catalyst (Fe/Al2O3) was placed. Scanning electron microscopy (SEM) investigation method used to study nanotubes produced, showed that high yield of two types of (CNTs) obtained, single wall carbon nanotube (SWCNTs) with diameter and length of less than 50nm and several micrometers respectively and nanocoil tubes with a diameter and length of less than 100nm and several micrometers respectively. The chemical analysis of (CNTs) reveals that the main component is carbon (94%) and a little amount of Al (0.32%), Fe (2.22%) the reminder is oxygen. It was also fou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Sep 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Synthesis and Characterization of Tri-Composite Activated Carbon
...Show More Authors

Activated carbon loading with metals oxides is new adsorbents and catalyst, which seem very promising for desulfurization process. The present study deals with the preparation of three metals oxides loaded on activated carbon (AC). The tri composite of ZnO/NiO/CoO/AC was characterized by X-Ray Diffraction (XRD), X-Ray florescence (XRF), N2 adsorption for BET surface area, pore volume and Atomic Force Microscopy (AFM). The effect of calcination temperature is investigated. The best calcination temperature is 250oC based on the presence of phase, low weight loss and keep at high surface area. The surface area and pore volume of prepared tri composite are 932.97m2/g and 0.6031cm3/g respec

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Corrosion protection of pure titanium implant by electrochemical deposition of hydroxyapatite post-anodizing
...Show More Authors

In this study, a Hydroxyapatite (HA) coating was prepared on a titanium implant by an electrochemical deposition process. The titanium pre-treatment by anodizing in 1.65 mol/L sulfuric acid with (10V) at room temperature. The deposition was all conducted at a constant voltage of 6.0 V, for 1 h at room temperature. The coatings thus prepared were characterized with Fourier transform infrared spectroscopy (FTIR) and thickness of the coated layer.The electrochemical deposition of HA occurred on the titanium as a cathode. Coated titanium by HA after anodizing revealed a good corrosion protection efficiency even at a temperature ranged (293-323) K in artificial saliva. Activation energy and pre-exponential factor (kinetic parameters) were calcul

... Show More
View Publication Preview PDF
Scopus (13)
Scopus
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Agricultural And Statistical Sciences
Production of potato under soilless culture
...Show More Authors

Scopus (7)
Scopus
Publication Date
Wed Jan 01 2025
Journal Name
Baghdad Science Journal
Determination of chlorpheniramine maleate in its pharmaceutical preparations using homemade turbidity flow injection analyzer
...Show More Authors

View Publication
Crossref