The AlAdhaim Dam is located 133 kilometers northeast of Baghdad. It is a multipurpose dam and joints the Iraqi dam system in 2000. It has a storage capacity of 1.5 billion m3. The dam has an ogee spillway with a length of 562 m, a crest level of 131.5 m.a.m.s.l. and a maximum discharge capacity of 1150 m3/s at its maximum storage height of 143 m.a.m.s.l. This research aimed to investigate the hydrodynamics performance of the spillway and the stilling basin of AlAdhiam Dam by using numerical simulation models under gated situations. It was suggested to modify the dam capacity by increasing the dam's storage capacity by installing gates on the crest of the dam spillway. The FLUENT program was used to simulate the flow over the spillway. The free surface was calculated using the volume of fluid (VOF) method. To deal with turbulence, the SST k-ω turbulence model was used. The study showed that the spillway is capable of carrying the designed flood discharge and the modified conditions with negative pressure behind the gate and at some points along the spillway. Hydraulic jumps occur at various distances throughout the plunge pool depending on the incoming velocity in the flip bucket.
Broadband satellite is playing a main role in provision global coverage and onboard processing ability over IP networks to assess user applications. In order to lower the cost, get better security, solve IPv4 addressing limitation, expand the expected advantages of modern routing and mobility characteristics; the next-generation satellite systems ought to support IPv6 and seamlessly incorporate with terrestrial networks including wireless local loops. Satellite communication links have a number of limitations compared to terrestrial communications networks such as large delay and high header overhead for IPv6 consumes the bandwidth and causes lower transmission effectiveness; however, the quality of service (QoS) (such as delay, jitter,
... Show MoreIn this research, non-thermal plasma system of argon gas is designed to work at normal atmospheric pressure and suitable for work in medical and biotechnological applications. This technique is applied in the treatment of the Staphylococcus epidermidis bacteria and show the role of the flow rate of Argon gas on the killing rate of bacteria, and it obtained a 100 % killing rate during the time of 5 minutes at the flow Argon gas of 5 liters/ min.
KA Hadi, AH Asma’a, IJONS, 2018 - Cited by 1
This paper aimed to determine the Optimal Reliable Frequency (ORF) that can maintain certain connection link between different transmitter/receiver stations laid over the Iraqi territory. Three different transmitting sites were chosen as tested stations located in the northern, central, and southern regions of Iraq. These sites are Mosul, Baghdad, and Basra, respectively. In this study, the years 2009 and 2014, which represent the minimum and maximum years of solar cycle 24, were chosen to examine the effect of low and high solar activity on the determined ORF. The datasets of the Best Usable Frequency (BUF) were calculated using the ASAPS international communication model. An analytical study was made on the generated BUF parameter data
... Show MoreLa condicionalidad en árabe, supongo como en otras lenguas, constituye una noción amplia que puede expresarse mediante diferentes construcciones sintácticas. La mayor parte de los especialistas coinciden en señalar que las estructuras condicionales son, probablemente, la clase más compleja de expresión compuesta en árabe. Se utilizan para expresar una condición de la que depende la realización de lo expuesto en la oración principal. Las estructuras condicionales son una de las principales vías lingüísticas de las que dispone el individuo para expresar su capacidad de imaginar situaciones diferentes a las reales; de crear mundos posibles; de soñar con situaciones pasadas que podrían haber sido diferentes; de ocultar lo fact
... Show MoreThe risk assessment for three pipelines belonging to the Basra Oil Company (X1, X2, X3), to develop an appropriate risk mitigation plan for each pipeline to address all high risks. Corrosion risks were assessed using a 5 * 5 matrix. Now, the risk assessment for X1 showed that the POF for internal corrosion is 5, which means that its risk is high due to salinity and the presence of CO, H2S and POF for external corrosion is 1 less than the corrosion, while for Flowline X2 the probability of internal corrosion is 4 and external is 4 because there is no Cathodic protection applied due to CO2, H2S and Flowline X3 have 8 leaks due to internal corrosion so the hazard rating was very high 5 and could be due to salinity, CO2, fluid flow rate
... Show MoreIn this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles