Numerical Study of Thermal Conductivity Effect on The Performance of Thermal Energy Storage
...Show More Authors

In this study, the effect of the thermal conductivity of phase change material (PCM) on the performance of thermal energy storage has been analyzed numerically. A horizontal concentric shell-and-tube latent heat thermal energy storage system (LHTESS) has been performed during the solidification process. Two types of paraffin wax with different melting temperatures and thermal conductivity were used as a PCM on the shell side, case1=0.265W/m.K and case2=0.311 W/m.K. Water has been used as heat transfer fluid (HTF) flow through in tube side. Ansys fluent has been used to analyze the model by taking into account phase change by the enthalpy method used to deal with phase transition. The numerical simulation assumptions were three-dimensional, transient, and laminar flow was used. The result for the PCMs of performance, temperature distribution, and liquid fraction during the discharge process were compared to each other. Furthermore, the Nusselt number was analyzed. The result showed that the increase in thermal conductivity of PCM reduces the time of the solidification process by 20%. The performance of LHTESS for case 2 is 63.2%, whereas for case1 is 54.6%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying the Performance of Refrigeration Units Powered by Solar Panel
...Show More Authors

An experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.

View Publication Preview PDF
Publication Date
Wed Oct 11 2017
Journal Name
International Journal Of Science And Research
Effect of Elevated Temperature on the Compressive Strength of Reactive Powder Concrete (RPC) Containing Polyvinyl Chloride (PVC)
...Show More Authors

Fire is the most sever environmental condition affecting on concrete structures, thus investigating for fire safety in structural concrete is important for building construction. The slow heat transfer and strength loss enables concrete to be effective for fire resistance. Concrete structures withstand when exposed to fire according to: their thermal properties, rate of heating, characteristic properties of concrete mixes and their composition and on the duration of fire, and concerned as thermal property with other factors such as loss of mass which affected by aggregate type, moisture content, and composition of concrete mix. The present research goal is to study the effect of rising temperature on the compressive strength of the rea

... Show More
Publication Date
Sun Oct 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Effect of Elevated Temperature on the Compressive Strength of Reactive Powder Concrete (RPC) Containing Polyvinyl Chloride (PVC)
...Show More Authors

Fire is the most sever environmental condition affecting on concrete structures, thus investigating for fire safet, IJSR, Call for Papers, Online Journal

View Publication
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Engineering
Performance Evaluation of Sequencing Batch Reactor and Conventional Wastewater Treatment Plant based on Reliability assessment
...Show More Authors

Baghdad city has been faced numerous issues related to freshwater environment deteriorations due to many reasons, mainly was the discharge of wastewater without adequate treatment. Al-Rustamiya Wastewater Treatment Plant (WWTP) have been constructed among many plants in Baghdad city to reduce the amount of wastewater discharged into natural environment and its subsequent adverse effects. This study was conducted to evaluate the performance of the plant which consist of a conventional activated sludge (CAS) and sequencing batch reactors (SBR) systems as secondary treatment units and its ability to meet Iraqi specifications. A reliability level determination and analysis also were conducted to find the plant's stability an

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Engineering
Performance evaluation of Sequencing Batch Reactor and Conventional Wastewater Treatment Plant based on Reliability assessment
...Show More Authors

Baghdad city has been faced numerous issues related to freshwater environment deteriorations due to many reasons, mainly was the discharge of wastewater without adequate treatment. Al- Rustamiya Wastewater Treatment Plant (WWTP) have been constructed among many plants in Baghdad city to reduce the amount of wastewater discharged into natural environment and its subsequent adverse effects. This study was conducted to evaluate the performance of the plant which consist of a conventional activated sludge (CAS) and sequencing batch reactors (SBR) systems as secondary treatment units and its ability to meet Iraqi specifications. A reliability level determination and analysis also were conducted to find the plant's stability and its capabi

... Show More
Publication Date
Mon Aug 01 2016
Journal Name
Indian Journal Of Natural Sciences
Effect of Gamma Radiation on the A.C Electrical and Dielectric Properties of Prepared Pure and Doped Polyaniline Salt
...Show More Authors

Purepolyaniline and doped with hydrochloric acid was prepared in different molarities at room temperature. The a.c electrical properties were stadied.AC conductivityσac (ω), is found to vary as ωS in the frequency range (100Hz-10MH), S< 1and decreases indicating a dominate hopping process. Thedielectric constant ε1and dielectric loss ε2 have been determined for bulk polyaniline. ε1 decrease with the increase frequency. Electrical conductivity measurements increase with the increases both of the amount of HCl and the dose of radiation. The dielectric investigations show decrease with dose radiation.

Preview PDF
Publication Date
Fri Jan 05 2024
Journal Name
Al-academy
Reading in the Scenery of the performance and its developments
...Show More Authors

The importance of this research in studying the actor life existence on the stage through the performance art;where as all the literary theatrical dimensions didn't ignore the importance of the actor's performance.
So, it is shed a light on the nature of the scenery in the actor's performance and what its representations in the temporary directions ……..
The research set off from the imitation as a human instinct to the performance of the actor in post-modernity theater; so the researcher found that there is a question must be answered which is :Is the actor live a regression state in his theatrical performance ,or that the performance of the actor connect with collective conscience of human being which is repeated in certain

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Mechanical Engineering
Improving the Performance of the Vehicle Suspension System Using Inerter
...Show More Authors

Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
The role of e-government in enhancing the institutional performance
...Show More Authors

Abstract

The research aims to study the role of e-government in enhancing institutional performance. The dimensions of e-government are: (support and commitment of senior management, technical structures, organization and human resources, knowledge and information, work procedures, attention to citizens' satisfaction, and client parties),while the dimensions of institutional performance are: (Service improvement, innovation, efficiency and effectiveness).

The research used electronic questionnaire as a main tool for data collection, The questionnaire included all the employees in the e-government project in Department of Government Coordinate and Citizen Affairs at the General Secretariat of the C

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 31 2014
Journal Name
Al-khwarizmi Engineering Journal
Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
...Show More Authors

Abstract

    This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season.     The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per m

... Show More