Preferred Language
Articles
/
joe-159
Structural Behavior of Confined Concrete Filled Aluminum Tubular (CFT) Columns under Concentric Load
...Show More Authors

This paper introduces an experimental study on the behavior of confined concrete filled aluminum tubular (CFT) column to improve strength design, ductility and durability of concrete composite structures under concentrically loaded in compression to failure. To achieve this: seven column specimens with same concrete diameter 100mm and without steel reinforcement have been examined through experimental testing, which are used to study the effects of the thickness of the aluminum tube encased concrete ( thickness : 0mm, 2mm, 3mm, 4mm and 5mm with same length of column 450mm), length of column (thickness 5mm and length of column 700mm) and durability (thickness 5mm and length of column 450mm) on the structural behavior of  (CFT) columns.

It is concluded from this work that the compression force capacity is affected by thicknesses of the aluminum tube with respect to reference specimen. Where the used of aluminum tube thicknesses in column specimens led to increased in load carrying capacity in range (16% for C2 -224% for C5 ). The specimen has a length of 700mm with 5mm thickness the decreased of strength was 0.06% than the specimen with 5mm thickness and length 450mm. For slender column the overall buckling was observed while the local buckling for the short column is the dominant failure shape. Regarding durability, no apparent difference has been found between the structural behavior of the specimen that immersed in aggressive solution and specimen in air.

 

Keywords: circular, column, aluminum, CFT, confinement

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Feb 01 2002
Journal Name
Journal Of Engineering /college Of Eng./university Of Baghdad
Study of group action of stone columns using FEM
...Show More Authors

Study of group action of stone columns using FEM

Publication Date
Fri Jan 01 2016
Journal Name
8th Conference On Power Electronics, Machines And Drives (pemd), Glasgow, Uk
Design of tubular moving magnet linear alternator for use with an external combustion - free piston engine
...Show More Authors

Scopus (15)
Crossref (13)
Scopus Crossref
Publication Date
Sun Dec 31 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study and Analysis of Concentric Shell and Double Tube Heat Exchanger Using Tio2 Nanofluid
...Show More Authors

In this paper, nanofluid of TiO2/water of concentrations of 0.002% and 0.004% volume was used. This nanofluid was flowing through heat exchanger of shell and concentric double tubes with counter current flow to the hot oil. The thermal conductivity of nanofluid is enhanced with increasing concentrations of the TiO2, this increment was by 19% and 16.5% for 0.004% and 0.002% volume respectively relative to the base fluid (water). Also the heat transfer coefficient of the nanofluid is increased as Reynold's number and nanofluid concentrations increased too. The heat transfer coefficient is increased by 66% and 49% for 0.004% and 0.002% volume respectively relative to the base fluid. This study showed that the friction

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 02 2018
Journal Name
American Academic Scientific Research Journal For Engineering, Technology, And Sciences
Girder Load Share for the Curved I-Girder Bridge Subjected to the Point Load
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Jun 02 2016
Journal Name
American Scientific Research Journal For Engineering, Technology, And Sciences
Girder Load Share for the Curved I-Girder Bridge Subjected to the Point Load
...Show More Authors

The objective of this research is to study experimentally and theoretically the girder vertical load share of the curved I-Girder bridges subjected to the point load in addition to the self-weigh and supper imposed dead loads. The experimental program consist of manufacturing and testing the five simply supported bridge models was scaled down by (1/10) from a prototype of 30m central span. The models carriageway central radii are 30 m, 15m or 10m. The girder spacing of the first two models is 175 mm with an overall carriageway width of 650mm. The girder spacing of the other three bridge models is 200mm with the overall carriageway width of 700 mm. The overall depth of the composite section was 164 mm. To investigate the effect of live load

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Mechanical Properties of MIG Joints for Dissimilar Aluminum Alloys
...Show More Authors

The research aims to investigate the effects of GMAW or MIG welding process on the mechanical properties of dissimilar aluminum alloys 2024-T351 and AA 6061- T651. A series of experimental techniques have been conducted to evaluate mechanical properties of the alloys, by carrying out hardness, tensile and bending tests for welded and un-welded specimens.

Metal inert gas (MIG) has been carried out on sheet metal using ER- 4043(AlSi5) as a filler metal and argon as shielded gas. The welded joints were tested by X-ray radiography and Faulty pieces were excluded.

Welding joints without defects are subjected to heat treatment including heating the joints in furnace to 170 °C for half an hour then air cooling to rel

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 01 2020
Journal Name
Structures
Experimental and numerical study on wrapping concrete cylinders post heating and cooling under preload using CFRP fabrics
...Show More Authors

This paper reports test results and describes a numerical investigation of the effectiveness of using carbon fibre reinforced polymer (CFRP) fabrics for strengthening concrete cylinders that have been undamaged and damaged due to heating under preload. The purpose of this research was to investigate whether there is any difference in the performance of CFRP-wrapped cylinders if the wrapping is done under preload, and those for which neither heating, cooling nor wrapping was done under preload. The cylinders were exposed to 30% of maximum load at ambient temperature during heating and cooling before being wrapped under preload. Of 18 Ø 100 × 200 mm identical cylinders, 6 were left as control samples without heating, 12 were exposed t

... Show More
Scopus (15)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Anodic Polarization of Anodized Aluminum Alloy 5052
...Show More Authors

Aluminum alloy 5052 had been anodized by sulfuric acid as an electrolyte under constant voltage and the anodic oxide film produce will be testing by potentiostatic anodic polarization .Two variables, which were considered as important variables, were studied. These variables are anodizing time 15,30 min. and sealing time 10,20 min., and the test by potentiostatic anodic polarization through electro chemical polarization measurements in solutions of 1N na2so4 ( PH= 1 ). The results are discussed in light of the rate of ionic current flow through the coating during anodic polarization measurements.

View Publication Preview PDF
Publication Date
Sun Apr 24 2022
Journal Name
Egyptian Journal Of Chemistry
A novel Tubular Electrochemical Reactor with a Spiral Design of Anode for Treatment of Petroleum Refinery Wastewater
...Show More Authors

View Publication
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Engineering
Finite Element Modeling of One-Way Recycled Aggregate Concrete Slabs Strengthened using Near-Surface Mounted CFRPs under Repeated Loading
...Show More Authors

This study offers numerical simulation results using the ABAQUS/CAE version 2019 finite element computer application to examine the performance, and residual strength of eight recycle aggregate RC one-way slabs. Six strengthened by NSM CFRP plates were presented to study the impact of several parameters on their structural behavior. The experimental results of four selected slabs under monotonic load, plus one slab under repeated load, were validated numerically. Then the numerical analysis was extended to different parameters investigation, such as the impact of added CFRP length on ultimate load capacity and load-deflection response and the impact of concrete compressive strength value on the structural performance of

... Show More
View Publication Preview PDF
Crossref (2)
Crossref