Preferred Language
Articles
/
joe-159
Structural Behavior of Confined Concrete Filled Aluminum Tubular (CFT) Columns under Concentric Load
...Show More Authors

This paper introduces an experimental study on the behavior of confined concrete filled aluminum tubular (CFT) column to improve strength design, ductility and durability of concrete composite structures under concentrically loaded in compression to failure. To achieve this: seven column specimens with same concrete diameter 100mm and without steel reinforcement have been examined through experimental testing, which are used to study the effects of the thickness of the aluminum tube encased concrete ( thickness : 0mm, 2mm, 3mm, 4mm and 5mm with same length of column 450mm), length of column (thickness 5mm and length of column 700mm) and durability (thickness 5mm and length of column 450mm) on the structural behavior of  (CFT) columns.

It is concluded from this work that the compression force capacity is affected by thicknesses of the aluminum tube with respect to reference specimen. Where the used of aluminum tube thicknesses in column specimens led to increased in load carrying capacity in range (16% for C2 -224% for C5 ). The specimen has a length of 700mm with 5mm thickness the decreased of strength was 0.06% than the specimen with 5mm thickness and length 450mm. For slender column the overall buckling was observed while the local buckling for the short column is the dominant failure shape. Regarding durability, no apparent difference has been found between the structural behavior of the specimen that immersed in aggressive solution and specimen in air.

 

Keywords: circular, column, aluminum, CFT, confinement

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 30 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Space-Charge Effect on Theoretical Design of the Electron Gun Operated under Finite Magnification Condition
...Show More Authors

A computer theoretical s1udy has been carried out in field of opto - clcctroniccs, to design  an electron  gun using the space charge effect.

The   distribution  of   axial  potential    upon   the  two   -electrode

immersion  lens  of  (L=l4mm)  has been  carried   out   using   Poisons equation and the  tinite  clement  method;  knowing  the first 11nd second derivation  of  the    axial   potential   and  the  solution   of  paraxial   ray equation, the  optical   prop

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2015
Journal Name
Journal Of Engineering
Structural Systems for Modern Architecture in Iraq Analysis Study to Dr. Qahtan Al-Madfa’i’s Architecture
...Show More Authors

Dr. Qahtan Al-Madfa’i’s architecture has been characterized by a particular characteristic that may be unique and extreme at the same time, that is the use of the distinctive three-dimensional structural coverings and the exploitation of structural construction to give an extra aesthetic touch to the composition of the building, to achieve the application of his universal ideas, which he strongly believed and defended.

      In the period of the marked urban decline that the country undergoes now, which urges us toward making a comparison between the beginning of the modern Iraqi architecture and its ascending path up to its peak and the periods of its decline until it reached a very

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
International Journal Of Drug Delivery Technology
New Metal Complexes Derived from Heterocyclic Schiff-base Ligand; Preparation, Structural Investigation and Biological Activity
...Show More Authors

The formation of a Schiff-base with N2O2 donor atoms derived from the hydrazine segment and its metal complexes are reported. The Schiff-base ligand; N’-((1R,2S,4R,5S,Z)-2,4-diphenyl-3-azabicyclo[3.3.1]nonan-9-ylidene)furan-2-carbohydrazide (HL) was prepared from the reaction of furan-2-carbohydrazide with (1R, 2R, 4R, 5S)-2,4-diphenyl-3-azabicyclo[3.3.1]nonan-9-one (M1) in ethanol medium. The reaction of the title ligand with selected metal ions Cr(III), Mn(II), Ni(II), Cu(II), Zn(II) and Cd(II) gave complexes with the general formula [M(L)Cl2], (where: M = Cr(III), Mn(II), Ni(II), Cu(II), Zn(II) and Cd(II)). Spectroscopic analyses Fourier transform infrared (FT-IR), Nuclear Magnetic Resonance (NMR) Carbon-13 nuclear magnetic res

... Show More
View Publication
Scopus (3)
Scopus Crossref
Publication Date
Sun Mar 12 2017
Journal Name
Al-academy
Structural mechanisms formative (Goldman) reading done Studio talk And their role in raising Criticism knowledge
...Show More Authors

Facing the receiver (critic) problematic understanding of modern art done, which turned positive professional image to symbolic language, which gave it authenticity previous Arts advantage, and this latest progress in critical reading contemporary and several mechanisms for analyzing literary texts and plastic, including textural fabric. And we suffer from the absence of cash the recipient culture (learner), so the current search goal focused on detecting structural mechanisms formative (Goldman) reading done modern art and its role in raising criticism knowledge (learner). Defining the theoretical framework of chapter II by discussing it; the first episode dealt with the textural fabric, while the latter was accomplished Studio talk, an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Aug 21 2021
Journal Name
Engineering, Technology & Applied Science Research
The Impact of Hybrid Fibers on Punching Shear Strength of Concrete Flat Plates Exposed to Fire
...Show More Authors

This study presents an investigation about the effect of fire flame on the punching shear strength of hybrid fiber reinforced concrete flat plates. The main considered parameters are the fiber type (steel or glass) and the burning steady-state temperatures (500 and 600°C). A total of 9 half-scale flat plate specimens of dimensions 1500mm×1500mm×100mm and 1.5% fiber volume fraction were cast and divided into 3 groups. Each group consisted of 3 specimens that were identical to those in the other groups. The specimens of the second and the third groups were subjected to fire flame influence for 1 hour and steady-state temperature of 500 and 600°C respectively. Regarding the cooling process, water sprinkling was applied directly aft

... Show More
View Publication
Crossref (9)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Studying the Combination Effect of Additives and Micro Steel Fibers on Cracks of Self-Healing Concrete
...Show More Authors

In this study, the effect of the combination of micro steel fibers and additives (calcium hydroxide and sodium carbonate) on the size of cracks formation and healing them were investigated. This study aims to apply the use of self-healing phenomenon to repair cracks and to enhance the service life of the concrete structures. Micro steel fibers straight type were used in this research with 0.2% and 0.4% by volume of concrete. A weight of 20 and 30 kg/m3 of Ca(OH)2 and 2 and 3 kg/m3 of Na2CO3 were used as a partial cement replacement. The results confirm that the concrete cracks were significantly self-healed up to 30 days re-curing. Cracks width up to 0.2 mm were comp

... Show More
View Publication Preview PDF
Publication Date
Wed May 01 2019
Journal Name
Iop Conf. Series: Materials Science And Engineering
Fire flame effect on the compressive strength of reactive powder concrete using different methods of cooling
...Show More Authors

This research foxed on the effect of fire flame of different burning temperatures (300, 400 and 500)oC on the compressive strength of reactive powder concrete (RPC).The steady state duration of the burning test was (60)min. Local consuming material were used to mixed a RPC of compressive strength around (100) MPa. The tested specimens were reinforced by (3.0) cm hooked end steel fiber of (1100) MPa yield strength. Three steel fiber volume fraction were adopted in this study (0, 1.0and 1.5)% and two cooling process were included, gradual and sudden. It was concluding that increasing burning temperature decreases the residual compressive strength for RPC specimens of(0%) steel fiber volume fraction by (12.16, 19.46&24.49) and (18.20, 27.77 &3

... Show More
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Dec 26 2017
Journal Name
International Journal Of Science And Research (ijsr)
Investigating the Effect of Using Waste Glass on the Properties of Asphalt Concrete Wearing Course Mixture
...Show More Authors

The reuse or recycling of waste materials in different aspects of life is served the objective of sustainability and be beneficial to society. In recent years, a wide variety of waste materials were used in pavement construction. One of these materials is glass that generally produces in large quantities and crushed glass can be considered feasible alternative source of aggregate for asphalt mixture production. This study focused on examining the asphalt mixture properties of wearing course using crushed glass as fine aggregates. Fine crushed glass with various percentages by total weight retained on sieve 2.36 mm, 0.3 mm and 0.075 mm was used in the study. The results indicate that mixes containing crushed glass had lower Marshall stabilit

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
The effect of using different fibres on the impact-resistance of slurry infiltrated fibrous concrete (SIFCON)
...Show More Authors
Abstract<p>Slurry infiltrated fibrous concrete (SIFCON) is a modern type of fibre reinforced concrete (FRC). It has unique properties; SIFCON is superior in compressive strength, flexural strength, tensile strength, impact resistance, energy absorption and ductility. Because of this superiority in these characteristics, SIFCON was qualified for applications of special structures, which require resisting sudden dynamic loads such as explosions and earthquakes. The main aim of this investigation is to determine the effect of fibre type on the apparent density of SIFCON and on performance under impact load. In this investigation, hook-end steel fibre and polyolefin fibre were used. Purely once and </p> ... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Mon Jan 08 2018
Journal Name
International Journal Of Science And Research
effect of steel fiber type on compressive strength and modules of rupture on reactive powder concrete
...Show More Authors