Preferred Language
Articles
/
joe-1536
The Design and Simulation of a Novel Optical Adder Depending on Optical Tri-state Gates
...Show More Authors

Essential approaches involving photons are among the most common uses of parallel optical computation due to their recent invention, ease of production, and low cost. As a result, most researchers have concentrated their efforts on it. The Basic Arithmetic Unit BAU is built using a three-step approach that uses optical gates with three states to configure the circuitry for addition, subtraction, and multiplication. This is a new optical computing method based on the usage of a radix of (2): a binary number with a signed-digit (BSD) system that includes the numbers -1, 0, and 1. Light with horizontal polarization (LHP) (↔), light with no intensity (LNI) (⥀), and light with vertical polarization (LVP) (↨) is represented by -1, 0, and 1, respectively. This research proposes new processor designs for addition. As a result, the design can achieve m addition operations with an operand length of n bits simultaneously. To explain and justify the theoretical design idea, the three steps of adding a BSD are numerically simulated. The constructing process is thought to be more precise and faster because the time to add does not depend on the length of the word. For all entries, all bits are implemented simultaneously, boosting the system's efficiency. A simulation model for six addition processes with a total bit count of 15 bits across all entries is presented in this work performing in a one-time parallelism manner.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Correlation Study of Retinol Binding Protein4, Vitamin A with Liver Function Enzymes in Iraqi Fracture Patients with and without DM2
...Show More Authors

Background: Recent research indicates that persistent inflammatory responses may contribute to the rise of diabetic nephropathy (DN) and diabetic cardiovascular disease (DCVD) in type 2 diabetes mellitus patients (DM2). Numerous molecules associated with inflammation and angiogenesis have been implicated in the development and progression of DN and DCVD, respectively. Methods: The subjects were separated into five groups: healthy controls (n= 25), type 2 diabetes mellitus patients (n= 30), type 2 diabetes mellitus patients with nephropathy DN (n= 30), and type 2 diabetes mellitus patients with cardiovascular disease DCVD (n= 30). The blood levels of irisin, IL-8, HbA1C, urea, and creatinine were determined. Results: In current study there w

... Show More
Publication Date
Mon Dec 07 2020
Journal Name
Iranian Journal Of Parasitology
Serum levels of il-12 and il-23 in breast cancer patients infected with toxoplasma gondii: A case-control study
...Show More Authors

Scopus (2)
Scopus
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Ocular Pharmacology And Therapeutics
Formulation and<i>In Vitro</i>Evaluation of Cyclosporine-A Inserts Prepared Using Hydroxypropyl Methylcellulose for Treating Dry Eye Disease
...Show More Authors

View Publication
Scopus (26)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Wed Aug 31 2022
Journal Name
F1000research
Inflammatory markers in patients who presented with acute coronary syndrome and history of COVID-19 infection: a cross-sectional study
...Show More Authors

Background: During the COVID-19 outbreak, the number of patients who have developed acute coronary syndromes (ACS) has soared rapidly, cardiovascular disease and mortality are influenced by the elevated inflammatory biomarkers. The aim of this study is to compare inflammatory markers between patients with ACS who hadn’t previously had COVID-19 and those who’d be infected within the preceding three months; as well as, evaluating the effect of statins on inflammatory biomarkers.

Methods: This is a comparative cross-sectional study of 42 patients who presented with ACS and had previously had COVID-19 and 48 patient who had never had CO

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Oncology And Radiotherapy
Comparting study of cytokeratin 18 fragment M65 with CA19-9 and CEA as a biomarker in Iraqi colon cancer patients
...Show More Authors

Scopus
Publication Date
Mon Jun 01 2020
Journal Name
Iraqi Journal Of Physics
Theoretical Model for Spectroscopic Study of Cu+2, Co+2, and Fe+3 Dissolved in Ethanol with A Different Concentrations
...Show More Authors

The absorption spectrum for three types of metal ions in different concentrations has been studying experimentally and theoretically. The examination model is by Gaius model in order to find the best fitting curve and the equation controlled with this behavior. The three metal ions are (Copper chloride Cu+2, Iron chloride Fe+3, and Cobalt chloride Co+2) with different concentrations (10-4, 10-5, 10-6, 10-7) gm/m3. The spectroscopic study included UV-visible and fluorescence spectrum for all different concentrations sample. The results refer to several peaks that appear from the absorption spectrum in the high concentration of all metal ions solution.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 07 2022
Journal Name
Journal Of Nuclear Engineering And Radiation Science
Radon and Exhalation Rate Measurement of Soil Samples in Al-Amiriya Area in Baghdad Governorate Using a Nuclear Track Detector
...Show More Authors
Abstract<p>Radon is the most dangerous natural radioactive component affecting the human population, since it is a radioactive gas that results from the decomposition process of uranium deposits in soil, rocks, and water, and it is damaging both humans and the ecosystem. The radon concentrations and exhalation rate in soil samples from various locations were determined using a passive approach with a CR-39 (CR-39 is Columbia Resin #39; it is allyl diglycol carbonate C12H18O7) detector in Amiriya region in Baghdad Governorate. The average values of radon concentrations are ranged from 47.3 to 54.2 Bq·m−3. From the obtained results, we can conclude that the values of all studied locations are</p> ... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu May 02 2013
Journal Name
Al-mustansiriyah
Synthesis, Spectroscopic and Biological Studies of a New some Complexes with N-Pyridine-2-Y1 methyl-benzene-1, 2-diamine.
...Show More Authors

Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Fabrication and characterization of zinc oxide nanorods coated by graphene oxide ZnO-NR@GO as a potential hybrid material photocatalyst
...Show More Authors

Hybrid architecture of ZnO nanorods/graphene oxide ZnO-NRs@GO synthesized by electrostatic self-assembly methods. The morphological, optical and luminescence characteristics of ZnO-NRs@GO and ZnO-NRs thin films have been described by FESEM, TEM, HRTEM, and AFM, which refers to graphene oxide have been coated ZnO-NRs with five layers. Here we synthesis ZnO-NRs@GO by simple, cheap and environmentally friendly method, which made it favorable for huge -scale preparation in many applications such as photocatalyst. ZnO-NRs@GO was applied as a photocatalyst Rodamin 6 G (R6G) dye from water using 532 nm diode laser-induced photocatalytic process. Overall degradation of R6G/ ZnO-NRs@GO was achieved after 90 minutes of laser irradiation while it ne

... Show More
View Publication
Scopus (4)
Scopus Crossref
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Spectrophotometric and Reverse Flow Injection Method Determination of Nitrazepam in Pharmaceuticals Using O-Coumaric Acid as a New Chromogenic Reagent
...Show More Authors

            A spectrophotometric- reverse flow injection analysis (rFIA) method has been proposed for the   determination of Nitrazepam (NIT) in pure and pharmaceutical preparations. The method is based upon the coupling reaction of NIT with a new reagent O-Coumaric acid (OCA) in the presence of sodium periodate in an aqueous solution. The blue color product was measured at 632 nm. The variation (chemical and physical parameters) related with reverse flow system were estimated. The linearity was over the range 15 - 450 µg/mL of NIT with detection limits and limit of quantification of 3.425 and 11.417 µg mL-1 NIT,respectively. The sample throughput of 28 samples

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (1)
Scopus Clarivate Crossref