Preferred Language
Articles
/
joe-149
Fire Flame Influence on the Behavior of reinforced Concrete Beams Affected by Repeated Load
...Show More Authors

The influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa).

To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the second method, sudden, water splash was used to reduce the temperature. Eight of the tested beams were divided in to four groups, each were burned to one of the adopted temperature for about half an hour and cooled by the adopted cooling methods (one by sudden cooling and the other by graduated cooling). After burning and cooling the beams were tested under the effect of repeated load (loading – unloading) for five cycle and then up to failure.

As a compared with the non- burned beam, the results indicated that the ultimate load capacity of the tested beams were reduced by (16, 23, 54 and 71)% after being burned to (200, 300, 400 and 500) oC , respectively, for a case of sudden cooling and by (8, 14, 36 and 64)% , respectively, for a case of graduated cooling. It was also found that the effect of sudden cooling was greater than that in a case of graduated cooling.

Regarding the failure mode, there was a different between the non-burred beam and the other ones even that all of them had the same geometric layout, compressive strength and reinforcement details. The failure mode for all burned beams was combined shear- flexure failure which was belong to the reduction in the compressive strength of the concrete due to the effect of the temperature rising , while the failure mode of the non-burned beam was flexure failure which was compatible with the preliminary design. It was also detected that the residual deflection proportion directly with the temperature, as the temperature increase to (200, 300, 400 and 500) oC the residual deflection compared with the non-burned beam increased by (32, 48, 326 and 358)% for a case of sudden cooling and by (13, 29, 303 and 332)%  for a case of graduated cooling. Another effect was appear represented by the method of cooling, the results showed that the sudden cooling had more effect on the residual deflection than the graduated cooling by (15-6)% approximately. To vanish the residual deflection, numbers of cycle (loading-unloading) were required. It was found that this number increase as the temperature of burning increased and it’s also larger in a case of sudden cooling.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 02 2023
Journal Name
Scripta Medica
The influence of socioeconomic status and general health on the fracture incidence
...Show More Authors

Background/Aim There is an association between patient general health, socioeconomic status and fracture incidence. Aim of this study was to demonstrate the relation between the socioeconomic and health status and the occurrence of fractures in Al-Kindy Hospital residents. Methods A prospective cross-sectional study was performed by using data collected from fractured patients in Al-Kindy Teaching Hospital / Baghdad Orthopaedics Outpatient Clinic, between 12 December 2021 and 8 March 2022. A hundred patients aged 20 to 75 years were included in this study. The data were collected using a researcher-administered questionnaire, which included items to assess patient's socioeconomic status (accommodations, occupation, income status, level of e

... Show More
Scopus
Publication Date
Tue Dec 09 2014
Journal Name
Journal Of The College Of Education For Women
A Stylistic Analysis of Bisson’s Bears Discover Fire
...Show More Authors

This paper aims at analyzing Terry Bisson’s short story Bears Discover Fire stylistically by following both Gerard Genette’s theory of narratology (1980) and Short and Leech (1981) strategy for analyzing fictional works. Also trying to examine to what extent these models are applicable in analyzing the selected story. Stylistic analysis procedures help the readers/researchers to identify specific linguistic features in order to support literary interpretation and appreciation of literary texts. Style in fiction concentrates not on what is written, but on how a text is written. Each writer has his own style and techniques which distinguish him from other writers

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Mon Dec 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Modeling and Simulation of a Fire Tube Boiler
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Aug 07 2020
Journal Name
Key Engineering Materials
Compressive Strength and Shrinkage Behavior of Concrete Produced from Portland Limestone Cement with Water Absorption Polymer Balls
...Show More Authors

From the sustainability point of view a combination of using water absorption polymer balls in concrete mix produce from Portland limestone cement (IL) is worth to be perceived. Compressive strength and drying shrinkage behavior for the mixes of concrete prepared by Ordinary Portland Cement (O.P.C) and Portland limestone cement (IL) were investigated in this research. Water absorbent polymer balls (WAPB) are innovative module in producing building materials due to the internal curing which eliminates autogenous shrinkage, enhances the strength at early age, improve the durability, give higher compressive strength at early age, and reduce the effect of insufficient external curing. Polymer balls (WAPB) had been used in the mixes of thi

... Show More
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Engineering
Permanent Deformation Characterization of Stone Matrix Asphalt Reinforced by Different Types of Fibers
...Show More Authors

This paper focused on the stone matrix asphalt (SMA) technology that was developed essentially to guard against rutting distress. For this procedure, fibers play a racy role in stabilizing and preventing the drain down problem caused by the necessity of high binder content coupled with their strengthening effect. A set of specimens with cylindrical and slab shapes were fabricated by inclusions jute, polyester, and carbon fibers. For each type, three contents of 0.25%, 0.5%, and 0.75% by weight of mixture were added by lengths of 5, 7.5, and 10 mm. The prepared mixtures were tested to gain the essential pertained parameters discriminated by the values of drain down, Marshall quotient, rut depth, and dynamic stability. It

... Show More
View Publication Preview PDF
Crossref (16)
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
The Combined Action of Zeolite and Chlorinated Rubber as Flame Retardants for Epoxy Resin
...Show More Authors

In this work , the effect of chlorinated rubber (additive I), zeolite 3A with chlorinated rubber (additive II), zeolite 4A with chlorinated rubber (additiveIII), and zeolite 5A with chlorinated rubber (additive IV), on flammability for epoxy resin studied, in the weight ratios of (2, 4, 7,10 & 12%) by preparing films of (130x130x3) mm in diameters, three standard test methods used to measure the flame retardation which are ; ASTM : D-2863 , ASTM : D-635 & ASTM : D-3014. Results obtained from these tests indicated that all of them are effective and the additive IV has the highest efficiency as a flame retardant.

View Publication Preview PDF
Crossref
Publication Date
Mon May 01 2017
Journal Name
2017 24th International Conference On Telecommunications (ict)
Load balancing by dynamic BBU-RRH mapping in a self-optimised Cloud Radio Access Network
...Show More Authors

View Publication
Crossref (8)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Ieee Systems Journal
Intelligent Traffic Management and Load Balance Based on Spike ISDN-IoT
...Show More Authors

An intelligent software defined network (ISDN) based on an intelligent controller can manage and control the network in a remarkable way. In this article, a methodology is proposed to estimate the packet flow at the sensing plane in the software defined network-Internet of Things based on a partial recurrent spike neural network (PRSNN) congestion controller, to predict the next step ahead of packet flow and thus, reduce the congestion that may occur. That is, the proposed model (spike ISDN-IoT) is enhanced with a congestion controller. This controller works as a proactive controller in the proposed model. In addition, we propose another intelligent clustering controller based on an artificial neural network, which operates as a reactive co

... Show More
Scopus (20)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Internal Convective Heat Transfer Effect on Iraqi Building Construction Cooling Load
...Show More Authors

This work involves the calculation of the cooling load in Iraqi building constructions taking in account the effect of the convective heat transfer inside the buildings. ASHRAE assumptions are compared with the Fisher and Pedersen model of estimation of internal convective heat transfer coefficient when the high rate of ventilation from ceiling inlet configuration is used. Theoretical calculation of cooling load using the Radiant Time Series Method (RTSM) is implemented on the actual tested spaces. Also the theoretical calculated cooling loads are experimentally compared by measuring the cooling load in these tested spaces. The comparison appears that using the modified Fisher and Pedersen model when large ventilation ra

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Engineering
Wind Interference Effect for Overall Design Load on Mid-Rise Building
...Show More Authors

The constructed building in the urban area is subject to wind characteristics due to the influence of surrounding buildings. The residential complexes currently being built in Iraq represent a case study for the subject of this research. Therefore, the objective of this study is to identify the interference effect because of adjacent buildings effects on the mid-rise building. The speed and pressure of the wind have been numerically simulated as well as wind load has been simulated by using a virtual wind tunnel which is available in Autodesk Robot Structural Analysis, RSA, software. Two identical adjacent buildings have been simulated and many coefficients were included in this study such as the spacing, directionality,

... Show More
View Publication Preview PDF
Crossref