Nowadays power systems are huge networks that consist of electrical energy sources, static and lumped load components, connected over long distances by A.C. transmission lines. Voltage improvement is an important aspect of the power system. If the issue is not dealt with properly, may lead to voltage collapse. In this paper, HVDC links/bipolar connections were inserted in a power system in order to improve the voltage profile. The load flow was simulated by Electrical Transient Analyzer Program (ETAP.16) program in which Newton- Raphson method is used. The load flow simulation studies show a significant enhancement of the power system performance after applying HVDC links on Kurdistan power systems. The bus voltages are significantly increased after connecting High Voltage Direct Current.
ABSTRACT— In primary teeth, root canal treatment is a time consuming and challenging procedure, particularly during the most important step in endodontic treatment which is the preparation of the canal. Pulpectomy is the treatment of choice in all the necrotic primary teeth. For better treatment protocol, advancing technology brought the rotary system to reduce the manual dexterity and improve the quality of treatment for pulpectomy. This study aimed to compare and assess the efficacy of cleaning and the time required for the instrumentation during the preparation of root canals of the primary molars using the rotary and the manual (conventional) systems. Thirty root canals of primary teeth were selected. These teeth submitted to a
... Show MoreIn recent years, there has been a very rapid development in the field of clean energy due to the huge increase in the demand, which prompted the manufacturers and the designers to increase the efficiency and operating life of the energy systems and especially for wind turbine. It can be considered that the control unit is the main key of the wind turbines. Consequently, it’s essential to understanding the working principle of this unit and spotlight on the factors which influence significantly on the performance of wind turbine system. Simulink technique is proposed to find the response of the wind turbine system under different working conditions. In this paper, it was investigated
The present work aims to improve the flux of forward osmosis with the use of Thin Film Composite membrane by reducing the effect of polarization on draw solution (brine solution) side.This study was conducted in two parts. The first is under the effect of polarization in which the flux and the water permeability coefficient (A) were calculated. In the second part of the study the experiments were repeated using a circulating pump at various speeds to make turbulence and reduce the effect of polarization on the brine solution side.
A model capable of predicting water permeability coefficient has been derived, and this is given by the following equations:
Z=Z0 +C.R.T/9.8(d2/D2+1) [Exp. [-9.8(d
Background: Hypertension and dyslipidemia are
cardiovascular risk factors that commonly coexist .
Objective : To evaluate the effects of ß - blocker
(Atenolol) , ACE inhibitor (Captopril) calcium Channel
blocker (Nefidipin ) and diuretics on serum lipid profiles .
Method: Thirty untreated hypertensive and 147
hypertensive patient treated with these antihypertensive
drugs, attending different public health clinics in Basrah
pronivce were enrolled in this study .
Serum lipid profile were determined enzymaticaly using kits
from BioMerieux, France .
Result : The study has revealed that ß-blocker do not
significantly affect total cholesterol ( TC ) and LDLcholesterol , but increase significantly triglycer
Background: Dyslipidemia is a major cause of
cardiovascular disease, which in turn, is the most
common cause of female morbidity and mortality.
Postmenopausal women (natural and surgical) are at
higher risk of developing cardiovascular disease,
especially coronary artery atherosclerosis.
Objective: To observe the relationship between blood
lipids: total cholesterol (TC), high density lipoproteincholesterol (HDL-C), low density lipoproteincholesterol (LDL-C), triglycerides (TGs), and very low
density lipoprotein- cholesterol (VLDL-C), LDL-C/
HDL-C ratio (atherogenic index) and menopausal
status, and to determine the co-factors that may explain
this relationship
Methods: A prospective, cross-sectional st
A study on the treatment and reuse of oily wastewater generated from the process of fuel oil treatment of gas turbine power plant was performed. The feasibility of using hollow fiber ultrafiltration (UF) membrane and reverse osmosis (RO) membrane type polyamide thin-film composite in a pilot plant was investigated. Three different variables: pressure (0.5, 1, 1.5 and 2 bars), oil content (10, 20, 30 and 40 ppm), and temperature (15, 20, 30 and 40 ᵒC) were employed in the UF process while TDS was kept constant at 150 ppm. Four different variables: pressure (5, 6, 7 and 8 bar), oil content (2.5, 5, 7.5 and 10 ppm), total dissolved solids (TDS) (100, 200,300 and 400 ppm), and temperature (15, 20, 30 and 40 ᵒC) were mani
... Show MoreCryptosporidiosis is mainly cause a persistent diarrhea in immune compromised patients, BALB/c mice have been suppressed by dexamethasone, tissue Th1, Th2 and Th17 cytokines concentrations in the ileum were significantly diminished in both infected and immunosuppressed mice. Level of IFN-g, TNF-a, IL-12, IL-6, IL-17A was increased in level, IL-4 didn’t increases, in both ileal and spleen tissue. Levels of above cytokines were examined in spleen in order to follow the proliferation of CD4+ T-cell during C. parvum infection.
With the increasing reliance on microgrids as flexible and sustainable solutions for energy distribution, securing decentralized electricity grids requires robust cybersecurity strategies tailored to microgrid-specific vulnerabilities. The research paper focuses on enhancing detection capabilities and response times in the face of coordinated cyber threats in microgrid systems by implementing advanced technologies, thereby supporting decentralized operations while maintaining robust system performance in the presence of attacks. It utilizes advanced power engineering techniques to strengthen cybersecurity in modern power grids. A real-world CPS testbed was utilized to simulate the smart grid environment and analyze the impact of cyberattack
... Show More