Preferred Language
Articles
/
joe-1471
Effect of Distributing Steel Fibers on Some Properties of Slurry Infiltrated Fiber Concrete
...Show More Authors

The slurry infiltrated fiber concrete (SIFCON) is nowadays considered a special type of high fiber content concrete; it is high strength and high performance material. This paper investigates the effect of spread steel fiber into the slurry mortar on some properties of SIFCON. According to fiber distribution, two sets were used in this investigation. The first set consisted of randomly distributing fibers inside the slurry. The second set was by placing the fibers in an orderly manner inside the slurry. Crimped steel fibers with an aspect ratio of (60) were used. Two different volume fractions percentage of (7% and 9%) by volume of mold were used in both sets for this study. Also, a w/c ratio of (0.35) and superplasticizer of (1%) by weight of cement was used to ensure the penetration of the slurry inside the fibers. The compressive and flexural strength were conducted on standard cubes (10*10*10) cm and prisms of (40*7*7) cm respectively to find the effect of how the steel fibers were distributed. The results showed that distributing the fibers randomly gave better results than the ordered distribution. The increment percentage in compressive strength and flexural strength were (1.5%, 6.9%, 23%, and 6.5%), respectively, for both sets and both fiber volume fractions (7% and 9%).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Nov 01 2019
Journal Name
International Journal Of Engineering
Structural Behavior of Axially Loaded Composite Concrete-steel Plate Shear Walls
...Show More Authors

Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Dec 28 2017
Journal Name
Al-khwarizmi Engineering Journal
Mechanical Properties and Corrosion Behavior of Low Carbon Steel Weldments
...Show More Authors

This research involves studying the mechanical properties and corrosion behavior of “low carbon steel” (0.077wt% C) before and after welding using Arc, MIG and TIG welding. The mechanical properties include testing of microhardness, tensile strength, the results indicate that microhardness of TIG, MIG welding is more than arc welding, while tensile strength in arc welding more than TIG and MIG.

The corrosion behavior of low carbon weldments was performed by potentiostat at scan rate 3mV.sec-1 in 3.5% NaCl to show the polarization resistance and calculate the corrosion rate from data of linear polarization by “Tafel extrapolation method”. The results indicate that the TIG welding increase the corrosion current d

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Engineering
Non-Destructive Testing of Carbon Fiber Reinforced Magnetic Reactive Powder Concrete Containing Nano Silica
...Show More Authors

This study involves the design of 24 mixtures of fiber reinforced magnetic reactive powder concrete containing nano Silica. Tap water has been used in mixing 12 of these mixtures, while the other 12 have been mixed using magnetic water. Nano Silica (NS) with ratios (1, 1.5, 2, 2.5 and 3) % were used. The results showed that the mixture containing 2.5%NS gives the highest compressive strength at age 7 days. Many different other tests were carried out, the results showed that the fiber reinforced magnetic reactive powder concrete containing 2.5% NS (FRMRPCCNS)  has the higher bulk density, dynamic modulus of elasticity, ultrasonic pulse velocity  electrical resistivity and lesser absorption than fiber reinforced

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Laser
Experimental Study to The Effect of Applying Stressing Force on Etched Polarization Maintaining Fiber as Hybrid Fabry-Perot /Mach-Zehnder inline fiber interferometer
...Show More Authors

Abstract: The increased interest in developing new photonic devices that can support high data rates, high sensitivity and fast processing capabilities for all optical communications, motivates a pre stage pulse compressor research. The pre-stage research was based on cascading single mode fiber and polarization maintaining fiber to get pulse compression with compression factor of 1.105. The demand for obtaining more précised photonic devices; this work experimentally studied the behavior of Polarization maintaining fiber PMF that is sandwiched between two cascaded singe mode fiber SMF and fiber Bragg gratings FBG. Therefore; the introduced interferometer performed hybrid interference of both Mach-Zehnder

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Key Engineering Materials
Push-Out Test of Steel-Concrete-Steel Composite Section for Pre-Installation and Post-Installation Techniques of Shear Connectors
...Show More Authors

Composite steel-concrete sections have a broad benefit through increasing structural strength as well as minimizing the self-loads. All past researches were concerned with pre-installed shear connectors (PRSC) in the manufacturing of composite sections. A new fabrication technique for steel-concrete-steel composite sections were presented in the current study by the post-installation shear connectors (POSC) passed-through an embedded polymerizing vinyl chloride (PVC) pipes. The performance of normal strength concrete prisms with a specified strength of 32 MPa connected to square steel tubes (SST) was investigated. Six specimens were fabricated in both methodologies, PRSC and POSC were experimentally tested by Push-out test. The spac

... Show More
View Publication
Scopus (11)
Crossref (10)
Scopus Crossref
Publication Date
Sun Apr 01 2007
Journal Name
Journal Of Engineering
CURVATURE DUCTILITYOF REINFORCED CONCRETE BEAMSECTIONS STIFFENED WITH STEEL PLATES
...Show More Authors

Publication Date
Thu Dec 24 2020
Journal Name
Advances In Civil Engineering
Analytical study on torsional behavior of concrete beams strengthened with fiber reinforced polymer laminates using softened truss model
...Show More Authors

This study aimed at evaluating the torsional capacity of reinforced concrete (RC) beams externally wrapped with fiber reinforced polymer (FRP) materials. An analytical model was described and used as a new computational procedure based on the softened truss model (STM) to predict the torsional behavior of RC beams strengthened with FRP. The proposed analytical model was validated with the existing experimental data for rectangular sections strengthened with FRP materials and considering torque-twist relationship and crack pattern at failure. The confined concrete behavior, in the case of FRP wrapping, was considered in the constitutive laws of concrete in the model. Then, an efficient algorithm was developed in MATLAB environment t

... Show More
Scopus (12)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Investigating the elastic and plastic behavior of I-steel beams by using carbon fiber laminates
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
A study of the effect of acid immersion on some physical properties of ( Epoxy – MgO) composites
...Show More Authors

In this study a polymeric composite material was prepared by hand
lay-up technique from epoxy resin as a matrix and magnesium oxide
(MgO) as a reinforcement with different weight fraction (5,10,15,
and 20)% to resin. Then the prepared samples were immersed under
normal condition in H2So4(1 M) solution, for periods ranging up to
10 weeks. The result revealed that the diffusion coefficient
decreasing as the concentration of MgO increase. Also we studied
Hardness for the prepared samples before and after immersion. The
result revealed that the hardness values increase as the concentration
of MgO increase, while the hardness for the samples after immersion
in H2SO4 dec

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 20 2019
Journal Name
Iraqi Journal Of Physics
The effect of volume fraction on the fatigue strength of unsaturated polyester / glass fiber composite
...Show More Authors

 In this work polymeric composites were done from unsaturated polyester as a matrix reinforced with glass fiber type (E-glass) with two different volume fraction 20% & 40%. Fatigue tests showed that the number of fatigue cycles to failure limit for samples reinforced with uniform (woven Roving 0-90°) E-glass fiber and random (continuous fibers) with volume fraction 40% more than that for the same samples with volume fraction 20%. Also the fatigue results showed that the uniform samples failed with fatigue cycles more than that of random.

View Publication Preview PDF
Crossref