This study deals with the serviceability of reinforced concrete solid and perforated rafters with openings of different shapes and sizes based on an experimental study that includes 12 post-fire non-prismatic reinforced concrete beams (solid and perforated). Three groups were formed based on heating temperature (room temperature, 400 °C, and 700 °C), each group consisting of four rafters (solid, rafters with 6 and 8 trapezoidal openings, and rafter with eight circular openings) under static loading. A developed unified calculation technique for deflection and crack widths under static loading at the service stage has been provided, which comprises non-prismatic beams with or without opening exposed to flexure concentrated force. Two approaches were used to compute the deflection: The first attempt was conducted by using the moment of inertia for solid non-prismatic beam and reduced for those with openings by the ratio of residual rafter self-weight. The second was performed by using the moment of inertia of transformed cracked sections depending on the segmental rafter method. The crack width was determined using the ACI code's equation. The analytical and experimental results were evaluated and found to be in good agreement.
Background: Type 1 diabetes mellitus (T1DM) is a common disease in childhood. A linear relation between glycemic control (HbA1c < 7) and onset or progression of complication was detected. Only few individuals achieve glycemic control.
Objective: To estimate the glycemic control among diabetic children attending tertiary center.
Methods: All diabetic children registered in the diabetic consultancy clinic in Children Welfare Teaching hospital (298) were included in the study. Case records were reviewed and information on demography, weight and height, age at diagnosis and HbA1c was requested.
Results: Out of the total, 23.8% diabetic children had glycemic control. Glycemic control was decreasing with age (p=0.001), significantl
Background: The 2006-2007 Iraqi Mental Health survey (IMHS) reported surprisingly low prevalence of alcohol and drug abuse in the Iraqi population. Since then anecdotal and clinical reports have suggested that abuse of alcohol and drugs in Iraq has increased. To investigate this possibility, we conducted a survey of drug and drug abuse at youth centers in Baghdad.
Objective: To investigate this possibility, we conducted a survey of drug and drug abuse at youth centers in Baghdad.
Patients and methods: A total of 2678 persons were included in this survey with male to female ratio of 3.8:1. They were randomly selected from youth centers located in different sectors in Baghdad (Sader city, Al-Rusafa side and Al-Karkh side). Composite
The influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa). To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the second method, sudden, water splash was use
... Show MoreAn experimental program was conducted to determine the residual of composite Steel Beams-Reinforced Concrete (SB-RC) deck floors fabricated from a rolled steel beam topped with a reinforced concrete slab, exposed to high temperatures (fire flame) of 300, 500, and 700ºC for 1 hour, and then allowed to cool down by leaving them in the lab condition to return to the ambient temperature. The burning results showed that, by exposing them to a fire flame of up to 300ºC, no serious permanent deflection occurred. It was also noticed that the specimen recovered 93% of 19.2 mm of the deflection caused by burning. The recovered deflection of burned composite SB-RC deck floor at 500ºC was 40% of 77.9 mm of the deflection caused by burning with a res
... Show MoreThe influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa).
To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the seco
... Show More