Sliding Mode Vibration Suppression Control Design for a Smart Beam
...Show More Authors

Active vibration control is the main problem in different structure. Smart material like piezoelectric make a structure smart, adaptive and self-controlling so, they are effective in active vibration control. In this paper piezoelectric elements are used as sensors and actuators in flexible structures for sensing and actuating purposes, and to control the vibration of a cantilever beam by using sliding mode control. The sliding mode controller (SMC) is designed to attenuate the vibration induced by initial tip displacement which is equal to 15 mm.  It is designed based on the balance realization reduction method where three states are selected for the reduced model from the 24th states that describe the cantilever beam according to the FEM. These states are most controllable and observable. The stability and control performance for the proposed SMC are proved using candidate Lyapunov function and the equivalent control concept. The control spillover, which is the sources of instability, is completely avoided as ensured within the control performance proof.

            Numerical simulations are preformed to test the vibration attenuation ability of the proposed SMC. For 15 mm initial tip displacement, the piezoelectric actuator was found able to reduce the tip displacement to about (0.2) mm within (2.5 s), while it is equal to (3.5) mm with the open loop case. Moreover, the induced chattering in system response, due to the discontinuous control action, is removed by approximating the signum function by a continuous arctan function. As a result  a smoother response are obtained with the same control performance as can be shown in the sliding variable, the control input voltage and the tip displacement plots.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 17 2022
Journal Name
Sustainability
Analysis and Residual Behavior of Encased Pultruded GFRP I-Beam under Fire Loading
...Show More Authors

In this paper, fire resistance and residual capacity tests were carried out on encased pultruded glass fiber-reinforced polymer (GFRP) I-beams with high-strength concrete beams. The specimens were loaded concurrently under 25% of the ultimate load and fire exposure (an increase in temperature of 700 °C) for 70 min. Subsequently, the fire-damaged specimens were allowed to cool and then were loaded statically until failure to explore the residual behaviors. The effects of using shear connectors and web stiffeners on the residual behavior were investigated. Finite Element (FE) analysis was developed to simulate the encased pultruded GFRP I-beams under the effect of fire loading. The thermal analyses were performed using the general-pu

... Show More
Scopus (8)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Mechanical Engineering Research And Developments
Development of natural convection heat transfer in heat sink using a new fin design
...Show More Authors

Scopus (1)
Scopus
Publication Date
Wed Dec 15 2021
Journal Name
Al-academy
Simulation of myths in industrial product design "the seven eyes amulet as a model"
...Show More Authors

The research is to identify the legend of the seven eyes amulet of Babylonian origin and the representations it carried of the link between the Babylonian past and the Islamic present presented in the design works of the promoted products, preserving its impact in the souls as a way to avoid the act of envy, and from this was the research problem that I want to get answers to, which That is (How was the legend of the seven-eyes amulet represented in the design of industrial products?), making its goal to identify how that legend was represented within the design work of marketed industrial products, and in order to reach the answer, the research presented many concepts starting with the legend in its various forms in industrial products.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 23 2021
Journal Name
Iraqi Journal Of Science
Design of a Sustainable City in Iraq Using SAM Program to Calculate Renewable Energy
...Show More Authors

    Urban design and human activity are main causes of environmental pollution and climate change, such as reliance on energy production plants, factories and transportation that depend on fossil fuels, in addition to transformation of most green areas into residential areas. This paper aims to establish a sustainable city with an environment friendly urban design that contributes to exploitation of natural resources in the generation of electric power, use of green means of transport and thus the reduction of pollution. Anah site was chosen as the best site for designing a sustainable city, with its natural resources, air quality and moderate climate. The total area of ​​the city is 9990187m2 divided into s

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (6)
Scopus Crossref
Publication Date
Thu Nov 30 2023
Journal Name
Iraqi Journal Of Science
Serum Iron, Ferritin, Erythroferrone and their Inter-Correlation In Adult Cigarette Smokers: A Case-Control study
...Show More Authors

                                                                                                                                                                                                                                                                                                                                                                                   

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat May 21 2011
Journal Name
The International Journal Of Advanced Manufacturing Technology
Magneto-rheological directional control valve
...Show More Authors

The main part in hydraulic system is directional control valve. Directional control valve has complex construction such as moving spool to control the direction of actuator for required speed. Magneto-rheological (MR) fluid is one of controllable fluids. Utilizing the MR fluid properties, direct interface can be realized between magnetic field and fluid power without the need for moving parts like spool in directional control valves. This study proposes the design of four ways/three position MR proportional directional control valve (4/3 MR valve). The construction of valve and the principle of work are presented. Analysis for magnetic circuit and simulation for valve performance were done. The experiment was conducted to show the principle

... Show More
View Publication
Scopus (30)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2010
Journal Name
International Journal Of Communication Networks And Distributed Systems
A novel Radon-based multi-carrier direct sequence code division multiple access transceiver design and simulation
...Show More Authors

Multi-carrier direct sequence code division multiple access (MC-DS-CDMA) has emerged recently as a promising candidate for the next generation broadband mobile networks. Multipath fading channels have a severe effect on the performance of wireless communication systems even those systems that exhibit efficient bandwidth, like orthogonal frequency division multiplexing (OFDM) and MC-DS-CDMA; there is always a need for developments in the realisation of these systems as well as efficient channel estimation and equalisation methods to enable these systems to reach their maximum performance. A novel MC-DS-CDMA transceiver based on the Radon-based OFDM, which was recently proposed as a new technique in the realisation of OFDM systems, will be us

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Effect of Saturation of Sandy Soil on the Displacement Amplitude of Soil Foundation System under Vibration
...Show More Authors

In this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. A physical model was manufactured to simulate steady state harmonic load at different operating frequencies. The effect of relative density, depth of embedment, foundation area as well as the imposed harmonic load was investigated. It was found that the amplitude of displacement of the foundation increases with increasing the amplitude of dynamic force and operating frequency meanwhile it decreases with increasing the relative density of sand, degree of saturation, depth of embedment and contact area of footing. The maximum displacement was noticed at 33.34 to 41.67 Hz. The maximum displaceme

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Reduction of Noise and Vibration of Spur Gear by Using Asymmetric Teeth Profiles with Tip Relief
...Show More Authors

Reduction of noise and vibration in spur gear experimentally by using asymmetric teeth profiles with tip relief was presented. Both of classical (symmetric) and asymmetric (with and without tip relief) spur gears are used in this work. Gear test rig was constructed to achieve torsional vibration measuring, and two modified cutters are designed and manufactured to achieve tooth profile modifications. First to cut asymmetric gear tooth with pressure angles (14.5o/25 o) without tip relief for loaded and unloaded tooth sides respectively, and second to cut asymmetric gear tooth with pressure angles (14.5o/25 o) for loaded and unloaded tooth sides respectively with tip relief to ach

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Effect of Saturation of Sandy Soil on the Displacement Amplitude of Soil Foundation System under Vibration
...Show More Authors

In this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. A physical model was manufactured to simulate steady state harmonic load at different operating frequencies. The effect of relative density, depth of embedment, foundation area as well as the imposed harmonic load was investigated. It was found that the amplitude of displacement of the foundation increases with increasing the amplitude of dynamic force and operating frequency meanwhile it decreases with increasing the relative density of sand, degree of saturation, depth of embedment and contact area of footing. The maximum displacement was noticed at 33.34 to 41.67 Hz. The maximum displacement amplitude respons

... Show More