Preferred Language
Articles
/
joe-1397
Flood Management of Diyala River
...Show More Authors

Diyala Governorate was recently exposed to high flood waves discharged from Hemrin Dam. Since the dam was at its full capacity during the flood period, these waves were discharged to the Diyala River. Because of the reduction in Diyala River capacity to 750m3/s, the cities and villages on both sides of the river banks were inundated. Thus, the study's objective is to design a flood escape out of the Diyala River, to discharge the flood wave through it. The flood escape simulation was done by using HEC- RAS software. Two hundred twenty-three cross sections for the escape and 30 cross-sections of the Diyala River were used as geometric data. Depending on the geological formation that the escape passed through, two roughness coefficients of 0.035 and 0.028 were applied. An outflow downstream Hemrin Dam varies from 1100m3/s to 1800m3/s was applied as boundary condition upstream Diyala River. One dimensional hydraulic model was developed for the escape and the river, the results showed that aside weir could be constructed at the escape entrance with crest level 67m.a.m.s.l. and 800m width, followed by drop structure of four rectangular steps, this case provides safe discharge to Diyala River if flood wave of 1500m3/s released from Hemrin Dam.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Aims Energy
The impact of different compression ratios on emissions, and combustion characteristics of a biodiesel engine
...Show More Authors

<p>The current work investigated the combustion efficiency of biodiesel engines under diverse ratios of compression (15.5, 16.5, 17.5, and 18.5) and different biodiesel fuels produced from apricot oil, papaya oil, sunflower oil, and tomato seed oil. The combustion process of the biodiesel fuel inside the engine was simulated utilizing ANSYS Fluent v16 (CFD). On AV1 diesel engines (Kirloskar), numerical simulations were conducted at 1500 rpm. The outcomes of the simulation demonstrated that increasing the compression ratio (CR) led to increased peak temperature and pressures in the combustion chamber, as well as elevated levels of CO<sub>2</sub> and NO mass fractions and decreased CO emission values un

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Jan 24 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Development and Characterization of Hyaluronic Acid-Incorporated Thermosensitive Nasal in situ Gel of Meclizine Hydrochloride
...Show More Authors

Background: Meclizine hydrochloride (MCZ) is an antihistamine that is used as an antiemetic to prevent and cure nausea and vomiting. Because of its limited water solubility and first-pass metabolism, it exhibits variable absorption. Objective: To formulate and evaluate MCZ as an intranasal in situ gel with increased residence time and permeability. Methods: We made an inclusion complex of MCZ using various cyclodextrins as a complexing agent to help the drug dissolve better. The complexes were studied, and the ones that were better at dissolving were chosen to be used in the creation of an in situ gel with poloxamer 407 (17–20% w/v) and hyaluronic acid (0.25–0.75% w/v). Prepared formulas were subjected to various evaluation tes

... Show More
View Publication
Scopus (7)
Crossref (6)
Scopus Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Preparation and studying of some properties of polymer composites reinforced with natural and artificial fibers
...Show More Authors

This work concerns the thermal and sound insulation as well as the mechanical properties of polymer matrix composite reinforced with glass fibers. These fibers may have dangerous effect during handling, for example the glass fibers might cause some damage to the eyes, lungs and even skin. For this reason the present work, investigates the behavior of polymer composite reinforced with natural fibers (Plant fibers) as replacement to glass fibers. Unsaturated Polyester resin was used as matrix material reinforced with two types of fibers, one of them is artificial (Glass fibers) and the other type is natural (Jute, Fronds Palm and Reed Fibers) by hand lay-up technique. All fibers are untreated with any chemical solvent. The Percentage of mi

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Feb 10 2025
Journal Name
Aip Conference Proceedings
Development of an HPLC method for the determination of tramadol hydrochloride using ZIC-HILIC columns
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research &amp; Development
Antibacterial Activity of Synergistic Effect of colicin and Gold Nanoparticles against <i>Klebsiella pneumonia</i>
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Sun Feb 21 2021
Journal Name
Iraqi Journal Of Science
The antimicrobial effects of alcoholic leaves extract of salvia officinalis against multidrug resistant pseudomonas aeruginosa
...Show More Authors

Scopus (11)
Scopus
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Innovation, Creativity And Change
The role of the forensic accountant in achieving the integration of accounting and legal performance
...Show More Authors

Scopus (2)
Scopus
Publication Date
Thu Sep 30 2021
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Mathematical Model, Simulation and Scale up of Batch Reactor Used in Oxidative Desulfurization of Kerosene
...Show More Authors

   In this paper, a mathematical model for the oxidative desulfurization of kerosene had been developed. The mathematical model and simulation process is a very important process due to it provides a better understanding of a real process. The mathematical model in this study was based on experimental results which were taken from literature to calculate the optimal kinetic parameters where simulation and optimization were conducted using gPROMS software. The optimal kinetic parameters were Activation energy 18.63958 kJ/mol, Pre-exponential factor  2201.34 (wt)-0.76636. min-1  and the reaction order 1.76636. These optimal kinetic parameters were used to find the optimal reaction conditions which

... Show More
View Publication Preview PDF
Crossref (15)
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Prediction of Compressive Strength of Reinforced Concrete Structural Elements by Using Combined Non-Destructive Tests
...Show More Authors

This research is devoted to investigate relationship between both Ultrasonic Pulse Velocity and Rebound Number (Hammer Test) with cube compressive strength and also to study the effect of steel reinforcement on these relationships.
A study was carried out on 32 scale model reinforced concrete elements. Non destructive testing campaign (mainly ultrasonic and rebound hammer tests) made on the same elements. About 72 concrete cubes (15 X 15 X15) were taken from the concrete mixes to check the compressive strength.. Data analyzed.Include the possible correlations between non destructive testing (NDT) and compressive strength (DT) Statistical approach is used for this purpose. A new relationships obtained from correlations results is give

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Response of composite steel-concrete cellular beams of different concrete deck types under harmonic loads
...Show More Authors
Abstract<p>This study aims to investigate the adequacy of composite cellular beams with lightweight reinforced concrete deck slab as a structural unit for harmonic loaded buildings. The experimental program involved three fixed-ends supported beams throughout 2140 mm. Three concrete types were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber Reinforced Aggregate Concrete (LWACF). The considered frequencies were (5, 10, 15, 20, 25, and 30) Hz. It was indicated that the harmonic load caused a significant influence on LWAC response (64% greater than NWC) and lattice cracks were observed, especially at 30 Hz. As for LWACF slab, no cracks appeared, </p> ... Show More
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref