Preferred Language
Articles
/
joe-1349
Practical comparation of the accuracy and speed of YOLO, SSD and Faster RCNN for drone detection
...Show More Authors

Convolutional Neural Networks (CNN) have high performance in the fields of object recognition and classification. The strength of CNNs comes from the fact that they are able to extract information from raw-pixel content and learn features automatically. Feature extraction and classification algorithms can be either hand-crafted or Deep Learning (DL) based. DL detection approaches can be either two stages (region proposal approaches) detector or a single stage (non-region proposal approach) detector. Region proposal-based techniques include R-CNN, Fast RCNN, and Faster RCNN. Non-region proposal-based techniques include Single Shot Detector (SSD) and You Only Look Once (YOLO). We are going to compare the speed and accuracy of Faster RCNN, YOLO, and SSD for effective drone detection in various environments. We have found that both Faster RCNN and YOLO have high recognition ability compared to SSD; on the other hand, SSD has good detection ability.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 21 2020
Journal Name
Baghdad Science Journal
Detection of Aflatoxin B1 among Early and Middle Childhood Iraqi Patients
...Show More Authors

      The study was conducted for the detection of Aflatoxin B1(AFB1) in the serum and urine of 42 early and middle childhood patients (26 male and  16 female ) with renal function disease, liver function disease, in additional to atrophy in the growth and other symptoms depending on the information within consent obtained from each patient, in addition to 8 children, apparently healthy, as  the control. The technique of HPLC was used for the detection of AFB1 from all samples. The results showed that out of 42 patient children, 19 (45.2%) gave positive detection of AFB1 in the serum among all age groups patients with a mean of 0.88 ng/ml and a range of (0.12-3.04) ng/ml. This was compared with the cont

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Physics: Conference Series
Disc damage likelihood scale recognition for Glaucoma detection
...Show More Authors
Abstract<p>Glaucoma is a visual disorder, which is one of the significant driving reason for visual impairment. Glaucoma leads to frustrate the visual information transmission to the brain. Dissimilar to other eye illness such as myopia and cataracts. The impact of glaucoma can’t be cured; The Disc Damage Likelihood Scale (DDLS) can be used to assess the Glaucoma. The proposed methodology suggested simple method to extract Neuroretinal rim (NRM) region then dividing the region into four sectors after that calculate the width for each sector and select the minimum value to use it in DDLS factor. The feature was fed to the SVM classification algorithm, the DDLS successfully classified Glaucoma d</p> ... Show More
View Publication
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Mon Oct 30 2023
Journal Name
Iraqi Journal Of Science
Machine Learning Approach for Facial Image Detection System
...Show More Authors

HM Al-Dabbas, RA Azeez, AE Ali, Iraqi Journal of Science, 2023

View Publication
Scopus (7)
Scopus
Publication Date
Mon Jun 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Wearable Detection Systems for Epileptic Seizure: A review
...Show More Authors

The seizure epilepsy is risky because it happens randomly and leads to death in some cases. The standard epileptic seizures monitoring system involves video/EEG (electro-encephalography), which bothers the patient, as EEG electrodes are attached to the patient’s head.

Seriously, helping or alerting the patient before the seizure is one of the issue that attracts the researchers and designers attention. So that there are spectrums of portable seizure detection systems available in markets which are based on non-EEG signal.

The aim of this article is to provide a literature survey for the latest articles that cover many issues in the field of designing portable real-time seizure detection that includes the use of multiple

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 30 2025
Journal Name
Gsc Advanced Research And Reviews
A comprehensive review of metal-organic framework based biosensors for detection of reactive oxygen species and hydrogen peroxide in biomedical applications
...Show More Authors

Metal-organic frameworks (MOFs) have emerged as revolutionary materials for developing advanced biosensors, especially for detecting reactive oxygen species (ROS) and hydrogen peroxide (H₂O₂) in biomedical applications. This comprehensive review explores the current state-of-the-art in MOF-based biosensors, covering fundamental principles, design strategies, performance features, and clinical uses. MOFs offer unique benefits, including exceptional porosity (up to 10,400 m²/g), tunable structures, biocompatibility, and natural enzyme-mimicking properties, making them ideal platforms for sensitive and selective detection of ROS and H₂O₂. Recent advances have shown significant improvements in detection capabilities, with limit

... Show More
View Publication
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Journal Of Engineering
Speed Controller of Three Phase Induction Motor Using Sliding Mode Controller
...Show More Authors

In this paper, an adaptive integral Sliding Mode Control (SMC) is employed to control the speed of Three-Phase Induction Motor. The strategy used is the field oriented control as ac drive system. The SMC is used to estimate the frequency that required to generates three phase voltage of Space Vector Pulse Width Modulation (SVPWM) invertor . When the SMC is used with current controller, the quadratic component of stator current is estimated by the controller. Instead of using current controller, this paper proposed estimating the frequency of stator voltage since that the slip speed is function of the quadratic current . The simulation results of using the SMC showed that a good dynamic response can be obtained under load

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Amultifaceted Review Journal In The Field Of Pharmacy
Zwitterionic ion chromatography coupled with ultraviolet detection for the quantification of 2-deoxyguanosine in human serum
...Show More Authors

Scopus (19)
Scopus
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
Flow Injection Analysis with Turbidity Detection for the Quantitative Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations
...Show More Authors

The main objective of this paper is to develop and validate flow injection method, a precise, accurate, simple, economic, low cost and specific turbidimetric method for the quantitative determination of mebeverine hydrochloride (MbH) in pharmaceutical preparations.  A homemade NAG Dual & Solo (0-180º) analyser which contains two identical detections units (cell 1 and 2) was applied for turbidity measurements. The developed method was optimized for different chemical and physical parameters such as perception reagent concentrations, aqueous salts solutions, flow rate, the intensity of the sources light, sample volume, mixing coil and purge time. The correlation coefficients (r) of the developed method were 0.9980 and 0.9986 for

... Show More
View Publication
Scopus (29)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
Flow Injection Analysis with Turbidity Detection for the Quantitative Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations
...Show More Authors

The main objective of this paper is to develop and validate flow injection method, a precise, accurate, simple, economic, low cost and specific turbidimetric method for the quantitative determination of mebeverine hydrochloride (MbH) in pharmaceutical preparations.  A homemade NAG Dual & Solo (0-180º) analyser which contains two identical detections units (cell 1 and 2) was applied for turbidity measurements. The developed method was optimized for different chemical and physical parameters such as perception reagent concentrations, aqueous salts solutions, flow rate, the intensity of the sources light, sample volume, mixing coil and purge time. The correlation coefficients (r) of the developed method were 0.9980 and 0.9986 for cell

... Show More
View Publication Preview PDF
Scopus (29)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Wed Nov 17 2021
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
Pearson coefficient matrix for studying the correlation of community detection scores in multi-objective evolutionary algorithm
...Show More Authors

View Publication
Scopus (7)
Crossref (2)
Scopus Crossref