Preferred Language
Articles
/
joe-1325
Physical Simulation for the Flow in Straight and Rectangular Loop Manifolds
...Show More Authors

The flow in a manifolds considered as an advanced problem in hydraulic engineering applications. The objectives of this study are to determine; the uniformity qn/q1 (ratio of the discharge at last outlet, qn to the discharge at first outlet, q1) and total head losses of the flow along straight and rectangular loop manifolds with different flow conditions. The straight pipes were with 18 m and 19 m long and with of 25.4 mm (1.0 in) in diameter each. While, the rectangular close loop configuration was with length of 19 m and with diameter of 25.4 mm (1.0 in) also. Constant head in the supply tank was used and the head is 2.10 m. It is found that outlets spacing and manifold configuration are the main factors affecting the uniformity of flow distribution and friction head losses along manifolds. For large value of outlets spacing, the uniformity coefficient (qn/q1) was found with greatest value of 0.96. Thus, the flow distribution improves with bigger spacing between outlets along manifold. For same manifold length, diameter, inlet head and spacing between outlets (S/L=0.079), the uniformity coefficient was found 0.881 or 88.1% for straight manifold and 0.926 for rectangular loop manifold. From the experimental data, a better uniformity is obtained from the rectangular loop manifold, this is because the friction head loss in rectangular loop manifold was lower than that in straight manifold. The lowest of total head losses was found with greatest outlet spacing along manifold, while the highest of total head losses was found with smallest outlets spacing along manifold. And, the lowest of total head loss was found with the rectangular manifold, while the highest of total head loss was found with the straight manifold.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 11 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Effects of Spontaneous Abortion upon Women's Physical and Spiritual Status
...Show More Authors

Background: Spontaneous abortion means that a pregnancy is lost prior to viability, the loss of a fetus weighing less than 500 g, and the loss of an embryo or fetus at 20 weeks gestation or less (WHO, 2001). Glenville, (2001) has reported that suffering a miscarriage is one of the most devastating things that can happen to a woman, and to her husband. Many women conceive easily and are not emotionally or physically prepared for the shock of losing a baby. Objective: To know effects of spontaneous abortion upon physical status and spiritual beliefs , also find out the association between physical status and spi

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Component of Pattern Materials and Its Influence on Physical Properties
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Dec 30 2015
Journal Name
Iraqi National Journal Of Nursing Specialties
Effects of Spontaneous Abortion upon Women's Physical and Spiritual Status
...Show More Authors

Background: Spontaneous abortion means that a pregnancy is lost prior to viability, the loss of a fetus weighing less than 500 g, and the loss of an embryo or fetus at 20 weeks gestation or less (WHO, 2001). Glenville, (2001) has reported that suffering a miscarriage is one of the most devastating things that can happen to a woman, and to her husband. Many women conceive easily and are not emotionally or physically prepared for the shock of losing a baby. Objective: To know effects of spontaneous abortion upon physical status and spiritual beliefs , also find out the association between physical status and spiritual beliefs with study variable (demographic & reproductive). Methodology: A descriptive Analytical study was conducted on Non

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (19)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Opcion
The effectiveness of using material flow cost accounting to eliminate losses
...Show More Authors

This investigation aimed to explain the mechanism of MFCA by applying this method on air-cooled engine factory which was suffering from high production cost. The results of this study revealed that MFCA is a useful tool to identify losses and inefficiencies of the production process. It is found that the factory is suffering from high losses due to material energy and system losses. In conclusion, it is calculated that system losses are the highest among all the losses due to inefficient use of available production capacity.

Scopus (2)
Scopus
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Numerical study of the mixed convection flow over a square cylinder
...Show More Authors

In this work, a numerical study is performed to predict the solution of two – dimensional, steady and laminar mixed convection flow over a square cylinder placed symmetrically in a vertical parallel plate. A finite difference method is employed to solve the governing differential equations, continuity, momentum, and energy equation balances. The solution is obtained for stream function, vorticity and temperature as dependent variables by iterative technique known as successive over relaxation. The flow and temperature patterns are obtained for Reynolds number and Grashof number at (Re= -50,50,100,-100) (positive or negative value refers to aidding or opposing buoyancy , +1 assisting flow, -1 opposing flow) and (102 to 105) , respective

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance of Subsurface Flow Constructed Wetland Systems in the Treatment of Al-Rustumia Municipal Wastewater using Continuous Loading Feed
...Show More Authors

This study aimed at comparing the performance of vertical, horizontal and hybrid subsurface flow systems in secondary treatment for the effluent wastewater from the primary basins at Al-Rustumia wastewater treatment plant, Baghdad, Iraq. The treatments were monitored for six weeks while the testsduration were from 4 to 12 September 2018 under continuous wastewater feeding for chemical oxygen demand (COD), total suspended solid (TSS),ammonia-nitrogen(NH4-N) and phosphate (PO4-P) in comparison with FAO and USEPA standards for effluent discharge to evaluate the suitability of treated water for irrigation purposes. Among the systems planted with Phragmites Australia, the hybrid subsurface flow system which cons

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
International Journal Of Drug Delivery Technology
Simple and Rapid Method For Estimate of Propranolol With Bi (III) Via Long-Distance Chasing Photometer (NAG-ADF-300-2) Utilization Continuous Flow Injection Analysis
...Show More Authors

A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the

... Show More
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Flow Injection Spectrophotometric Determination of Thymol using 4-Aminoantipyrine and Copper(II) Nitrate
...Show More Authors

Flow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 05 2011
Journal Name
Baghdad Science Journal
A Study of Some Physical Properties for Binary System of Cyclohexane with n-decane and 1-pentanol at Different Temperatures
...Show More Authors

mixtures of cyclohexane + n-decane and cyclohexane + 1-pentanol have been measured at 298.15, 308.15, 318.15, and 328.15 K over the whole mole fraction range. From these results, excess molar volumes, VE , have been calculated and fitted to the Flory equations. The VE values are negative and positive over the whole mole fraction range and at all temperatures. The excess refractive indices nE and excess viscosities ?E have been calculated from experimental refractive indices and viscosity measurements at different temperature and fitted to the mixing rules equations and Heric – Coursey equation respectively to predict theoretical refractive indices, we found good agreement between them for binary mixtures in this study. The variation of th

... Show More
View Publication Preview PDF
Crossref