Water/oil emulsion is considered as the most refractory mixture to separate because of the interference of the two immiscible liquids, water and oil. This research presents a study of dewatering of water / kerosene emulsion using hydrocyclone. The effects of factors such as: feed flow rate (3, 5, 7, 9, and 11 L/min), inlet water concentration of the emulsion (5%, 7.5%, 10%, 12.5%, and 15% by volume), and split ratio (0.1, 0.3, 0.5, 0.7, and 0.9) on the separation efficiency and pressure drop were studied. Dimensional analysis using Pi theorem was applied for the first time to model the hydrocyclone based on the experimental data. It was shown that the maximum separation efficiency; at split ratio 0.1, was 94.3% at 10% concentration and 11 L/min flow rate; at 0.3 split ratio, was 70.8% at 10% concentration and 11 L/min flow rate; at split ratio 0.5, was 82.1% at 12.5% concentration and 11 L/min flow rate; at split ratio 0.7, was 70% at 11 L/min, for 5%, 7.5%, and 12.5% concentrations; at 0.9 split ratio was 96.8% at 11 L/min flow rate and 5% concentration. The maximum separation obtained within these ranges of variables was 96.8% at 0.9 split ratio, 11 L/min flow rate and 5% concentration. The maximum pressure drop recorded was 3.6 bar at split ratio 0.1 and 11 L/min flow rate for all concentrations. The correlations obtained by the dimensional analysis were; at split ratio 0.1, at split ratio 0.3, at split ratio 0.5, at split ratio 0.7, and at split ratio 0.9. As an average for all the studied variables.
The research aims to find approximate solutions for two dimensions Fredholm linear integral equation. Using the two-variables of the Bernstein polynomials we find a solution to the approximate linear integral equation of the type two dimensions. Two examples have been discussed in detail.
The accreditation of a fast, inexpensive, and simple way to discriminate between different kinds of oils and their efficacy “degree of consumption (DoC)†has been developed. The fluorescence spectroscopy provides a reliable method for oil inspection without resorting to tedious separation.
Different new and used oil samples available in the local Iraqi market were investigated. While the challenge is to build a directory containing data of all the oils available in the local market. This method expected to control the falsified (forged) trademarks of motor oils and to discriminate between different oils.
The excitation-emission spectra of oil samples were determined in the range of 200 â€
... Show MoreThe study was conducted to vaccinate chickens against coccidiosis using alive vaccine contain seven species of chicken Eimeria, E. tenella, E. brunetti, E. necatrix, E. maxima, E. mevati, E. acervulina and E. praecox. A total of 120 chicks were divided into two main groups: broiler group and egg laying group. The birds of each group were allocated on to three pins, each contains 20 chicks. The birds of the experiment were vaccinated at day nine of age, with a suspension of mixed Eimeria which contain 50 Oocysts of E. tenella with a different percent of other species, respectively. The vaccine was given to chicks in the 1st pins of each group with drinking water, the chicks in th
... Show MoreThe multimetric Phytoplankton Index of Biological Integrity (P-IBI) was applied throughout Rostov on Don city (Russia) on 8 Locations in Don River from April – October 2019. The P-IBI is composed from seven metrics: Species Richness Index (SRI), Density of Phytoplankton and total biomass of phytoplankton and Relative Abundance (RA) for blue-green Algae, Green Algae, Bacillariophyceae and Euglenaphyceae Algae. The average P-IBI values fell within the range of (45.09-52.4). Therefore, water throughout the entire study area was characterized by the equally "poor" quality. Negative points of anthropogenic impact detected at the stations are: Above the city of Rostov-on-Don (1 km, higher duct Aksai) was 38.57 i
... Show MoreIn this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies
... Show MoreThis study aims to find the effect of water-cement ratio on the compressive strength of concrete by using ultrasonic pulse velocity test (UPVT). Over 230 standard cube specimens were used in this study, with dimensions of 150mm, and concrete cubes were cured in water at 20 °C. Also, the specimens used in the study were made of concrete with varied water-cement ratio contents from 0.48 to 0.59. The specimens were taken from Diyarbakir-Turkey concrete centers and tested at the structure and material science lab, civil engineering, faculty of engineering from Dicle University. The UPV measurement and compressive strength tests were carried out at the concrete age of 28 days. Their UPV and compressive strength ranged
... Show MoreThis research takes up address the practical side by taking case studies for construction projects that include the various Iraqi governorates, as it includes conducting a field survey to identify the impact of parametric costs on construction projects and compare them with what was reached during the analysis and the extent of their validity and accuracy, as well as adopting the approach of personal interviews to know the reality of the state of construction projects. The results showed, after comparing field data and its measurement in construction projects for the sectors (public and private), the correlation between the expected and actual cost change was (97.8%), and this means that the data can be adopted in the re
... Show MoreThe study attempts to assess water quality in Abu-Zirig Marsh which used epiphytic Diatom community for assessing water quality. Many of Diatom indices {Trophic diatom index (TDI), Diatom index (DI), Generic diatom index (GDI) have been used to give qualitative information about the status of the freshwater ecosystem(good, moderate, high pollution). In this study, the epiphytic diatoms on both host aquatic plants Phragmites australis and Typha domengensis were collected from Abu-Zirig Marsh within Thi-Qar Province at three sites in Autumn, 2018 and winter, 2019. Epiphytic diatoms were Identified by the preparation of permanent slides method, some species of epiphytic diatom showed dominance such as Cyclotella menegh
... Show MoreIn this research we study one of the pollutants(Gelbstoff ) such as Humic and Fulvic Acids in tap waters by using the technique of Raman, Flora to some regions of Baghdad , the results appear that the tap waters were pollutants which know yellow substance or Gelbstoff instant of suspending waters, which appear through the scattering of the incident light to same the wave length of Raman ,also calculate Raman shift which was 3640 cm-1 and force constant to band (O – H ) was 743 N/m, where the peak of Raman was at the wave length 441 nm after used the excitation wave length 380 nm . The results were in an agreement with lectures [8][9][10].