Preferred Language
Articles
/
joe-1172
Evaluating Electrocoagulation Process for Water Treatment Efficiency Using Response Surface Methodology
...Show More Authors

The electrocoagulation process became one of the most important technologies used for water treatment processes in the last few years. It’s the preferred method to remove suspended solids and heavy metals from water for treating drinking water and wastewater from textile, diary, and electroplating factories. This research aims to study the effect of using the electrocoagulation process with aluminum electrodes on the removal efficiency of suspended solids and turbidity presented in raw water and optimizing by the response surface methodology (RSM). The most important variables studied in this research included electrode spacing, the applied voltage, and the operating time of the electrocoagulation process. The samples were taken from the Al Qadisiyiah water treatment plant. The treatment set up was in a batch mode; two parallel plates of aluminum were used as electrodes. Experimental results showed that the maximum removal efficiency of 96% for turbidity and 97% for TSS were obtained at operating time 60 minutes, voltage 30 V, and electrode spacing 1.7cm. Two models for predicting removal efficiency obtained, the first model was for turbidity with a correction factor of 94.7%, and the second one was for the TSS with a correction factor of 94.85%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
INITIAL COLLECTION EFFICIENCY FOR GLASS FILTER MEDIA
...Show More Authors

This study investigated the ability of using crushed glass solid wastes in water filtration by using a pilot plant, constructed in Al-Wathba water treatment plant in Baghdad. Different depths and different grain sizes of crushed glass were used as mono and dual media with sand and porcelaniate in the filtration process. The mathematical model by Tufenkji and Elimelech was used to evaluate the initial collection efficiency η of these filters. The results indicated that the collection efficiency varied inversely with the filtration rate. For the mono media filters the theoretical ηth values were more than the practical values ηprac calculated from the experimental work. In the glass filter ηprac was obtained by multiplying ηth by a facto

... Show More
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
INITIAL COLLECTION EFFICIENCY FOR GLASS FILTER MEDIA
...Show More Authors

This study investigated the ability of using crushed glass solid wastes in water filtration by using a pilot plant, constructed in Al-Wathba water treatment plant in Baghdad. Different depths and different grain sizes of crushed glass were used as mono and dual media with sand and porcelaniate in the filtration process. The mathematical model by Tufenkji and Elimelech was used to evaluate the initial collection efficiency η of these filters. The results indicated that the collection efficiency varied inversely with the filtration rate. For the mono media filters the theoretical ηth values were more than the practical values ηprac calculated from
the experimental work. In the glass filter ηprac was obtained by multiplying ηth by a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2013
Journal Name
Journal Of Geochemical Exploration
Geochemical exploration using surveys of spring water, hydrocarbon and gas seepage, and geobotany for determining the surface extension of Abu-Jir Fault Zone in Iraq: A new way for determining geometrical shapes of computational simulation models
...Show More Authors

View Publication
Crossref (34)
Crossref
Publication Date
Wed Dec 26 2018
Journal Name
Iraqi Journal Of Science
Use Isotopes to Identity the Origin of Surface Water and Groundwater in ameriyat AL-Fallujah, Center Iraq
...Show More Authors

     Isotope tracer methods were used to determine flow paths, recharge areas, and relative age for groundwater in the Ameriyat Al- Falluja Al-Anbar governorate. The isotope of surface water and groundwater in the Ameriyat Al- Falluja area was assessed using a stable isotope technique. Data stable isotope parameters (2H and 18O) for three surface water and five groundwater samples were detected. The comparison of hydrogen and oxygen isotope compositions between groundwater and Euphrates River water demonstrated that the composition of the hydrogen and oxygen isotopes from Euphrates River matched that of the local meteoric water. This indicated that rainfall is the primary source of the river wate

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Molding and simulation sedimentation process using finite difference method
...Show More Authors
Abstract<p>The goal of this research is to develop a numerical model that can be used to simulate the sedimentation process under two scenarios: first, the flocculation unit is on duty, and second, the flocculation unit is out of commission. The general equation of flow and sediment transport were solved using the finite difference method, then coded using Matlab software. The result of this study was: the difference in removal efficiency between the coded model and operational model for each particle size dataset was very close, with a difference value of +3.01%, indicating that the model can be used to predict the removal efficiency of a rectangular sedimentation basin. The study also revealed</p> ... Show More
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Concentration of Orange Juice Using Forward Osmosis Membrane Process
...Show More Authors

Forward osmosis (FO) process was applied to concentrate the orange juice. FO relies on the driving force generating from osmotic pressure difference that result from concentration difference between the draw solution (DS) and orange juice as feed solution (FS). This driving force makes the water to transport from orange juice across a semi-permeable membrane to the DS without any energy applied. Thermal and pressure-driven dewatering methods are widely used, but they are prohibitively energy intensive and hence, expensive. Effects of various operating conditions on flux have been investigated. Four types of salts were used in the DS, (NaCl, CaCl2, KCl, and MgSO4) as osmotic agent and the experiments were performed at the concentration of

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Ibuprofen Degradation from Synthetic Wastewater Using Photo-Fenton Process
...Show More Authors

   The removal of Ibuprofen antibiotics (IBU) by photo-degradation UV/H2O2/Fe+2 system was investigated in a batch reactor under different initial concentrations of H2O2 (100-500) mg/L, Fe+2 (10-40) mg/L, pH (3-9) and initial concentrations of IBU (10-80) mg/L, and their relationship with the degradation efficiency were studied. The result demonstrated that the maximum elimination of IBU was 85.54% achieved at 300 mg/L of H2O2, 30 mg/L of Fe+2, pH=3, and irradiation time of 150 min, for 10 mg/L of IBU. The results have shown that the oxidation reagent H2O2 plays a very important role in IBU degradation.

View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Https://www.researchgate.net/journal/iop-conference-series-materials-science-and-engineering-1757-899x
Application of multivariate statistical techniques in the evaluation of large-scale water treatment plants in Baghdad.
...Show More Authors
Abstract<p>This paper aims to evaluate large-scale water treatment plants’ performance and demonstrate that it can produce high-level effluent water. Raw water and treated water parameters of a large monitoring databank from 2016 to 2019, from eight water treatment plants located at different parts in Baghdad city, were analyzed using nonparametric and multivariate statistical tools such as principal component analysis (PCA) and hierarchical cluster analysis (HCA). The plants are Al-Karkh, Sharq-Dijlah, Al-Wathba, Al-Qadisiya Al-Karama, Al-Dora, Al-Rasheed, Al-Wehda. PCA extracted six factors as the most significant water quality parameters that can be used to evaluate the variation in drinkin</p> ... Show More
Crossref
Publication Date
Wed Feb 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Performance Evaluation of the Organic Matter Removal Efficiency in Wastewater Treatment Plants; Case study Al- Diwaniyah WWTP in Iraq
...Show More Authors

This study aims to assess the removal efficiency andestablish the BOD5 and COD statisticalcorrelation of the sewage flowing in Al-Diwaniyah wastewater treatment plant in Iraq during the study period (2005-2016). The strength of the influent wastewater entering the plant varied from medium to high in strength. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate evaluation of liquid waste and optimal control process. The equations

... Show More