New technologies have risen into popularity causing the Liquid membrane techniques to evolve over other separation techniques due to its high selectivity and recovery, increased fluxes, and reduced investment and operating cost. This work focuses on extracting Methylene Blue (MB), a cationic dye using a simple BLM separation technique from its aqueous phase. It combines extraction and stripping in a single unit operation. The feed phase was an aqueous solution of MB, the solvent chosen was soybean oil for the liquid/organic membrane phase, and tri-octyl amine acted as a carrier. The strip phase was a hydrochloric acid solution for this study. A two-phase equilibrium study was done to choose the correct solvent, carrier, and receiving phase (soybean oil, tri-octyl amine, and HCl) were chosen, which was then followed by a three-phase study. Effect of various parameters like equilibrium time, feed and stripping phase pH, stirring speed, carrier concentration, initial feed concentration, and strip phase concentration were all studied to find out the most optimum working condition for maximum extraction and recovery of MB. The removal efficiency of MB by using soybean oil was found as 92%, at the optimum process conditions for the transport of MB were found as follows: pH in the feed phase (11), pH in the stripping phase (5), initial concentration of MB (20 ppm), carrier concentration (7%) (v/v) TOA and stirring speed (250 rpm), respectively.
There are still areas around the world suffer from severe shortage of freshwater supplies. Desalination technologies are not widely used due to their high energy usage, cost, and environmental damaging effects. In this study, a mathematical model of single-bed adsorption desalination system using silica gel-water as working pair is developed and validated via earlier experiments. A very good match between the model predictions and the experimental results is recorded. The objective is to reveal the factors affecting the productivity of fresh water and cooling effect in the solar adsorption system. The proposed model is setup for solving within the commercially-available software (Engineering Equation Solver). It is implemented to so
... Show MoreThe removal of COD from wastewater generated by petroleum refinery has been investigated by adopting electrocoagulation (EC) combined with adsorption using activated carbon (AC) derived from avocado seeds. The process variables influencing COD removal were studied: current density (2–10 mA/cm2), pH (4–9), and AC dosage (0.2–1 g/L). Response surface methodology (RSM) based on Box–Behnken design (BBD) was used to construct a mathematical model of the EC/AC process. Results showed that current density has the major effect on the COD removal with a percent of contribution 32.78% followed by pH while AC dosage has not a remarkable effect due to the good characteristics of AC derived from avocado seeds. Increasing current density gives be
... Show MoreThe kinetic of atropine pertraction from seeds of Datura Metel Linn plant was studied. Diisopropyl ether, n-hexane and n-heptane were used as membranes for atropine recovery. The effect of speed of agitation and time in the range of 200-300 rpm and 0-3.5h, respectively were studied using the proposed membranes. The pertraction experiments were carried outs in a batch laboratory unit. The liquid-liquid pertraction was found to be very suitable for atropine recovery from its liquid extracts of Datura Metel seeds. A high purity (94-96%) can be obtained in the receiver phase. The pertraction process was found to be very selective for atropine recovery with diisopropyl ether membrane. As the speed of agitation increases the efficiency of pertrac
... Show MoreThree isolated bacteria were examined to remove heavy metals from the industrial wastewater of the Diala State Company of Electrical Industries, Diyala-Iraq. The isolated bacteria were identified as Pseudomonas aeruginosa, Escherichia coli and Sulfate Reducing Bacteria (SRB). The three isolates were used as an adsorption factor for different concentrations of Lead and Copper (100, 150, and 200 ppm.), in order to examine the adsorption efficiency of these isolates. In addition, the effect of three factors on heavy metals adsorption were examined; temperature (25, 30, and 37 ?C), pH (3 and 4.5) and contact time (2 and 24 hrs). The results showed that the highest level of lead adsorption was obtained at 37 ?C by E. coli, P, aerugenosa and
... Show MoreThis study was designed to determine the colonization of the in-use hand washing soaps in hospital settings. It is a comparative cross-sectional research in a surgical specialties and Baghdad teaching hospital in Baghdad, Iraq. Swabs from surfaces of bar soaps and from liquid soaps via their applicator tips; at the sinks of toilets of hospital staff and working rooms of the wards were taken in January 2008. Conventional microbiologic methods were used for culture of the swabs and identification of the isolates. Colonization was detected 60% and 15.9% in bars and liquid forms respectively. And this lead to the conclusion that bar soaps could be colonized with microorganisms excessively. Liquid hand washing soaps are more appropriate in ho
... Show MoreCharge transfer (CT) at liquid/liquid interfaces are described theoretically depending on the quantum theory .A model that derived used to calculate the rate constant of transport at liquid/liquid interfaces. The calculation of the rate constant of charge transfer depends on the calculation of the reorganization energy, driving force ,and the coupling coefficient . Large reorganization energies and large rate constant for charge transfer ,indicate that the transitions involve more energy to happen . The system have large ð¸0 (ð‘’ð‘‰) refers that type of liquid is more reactive media than other liquid types with same d
... Show More