Preferred Language
Articles
/
joe-115
Analytical and Experimental Investigation for the Effect of Air Injection Angle on the Performance of Airlift Pump
...Show More Authors

The effect of air injection angle on the performance of airlift pump used for water pumping has been studied analytically and experimentally. An airlift pump of dimensions 42mm diameter and 2200 mm length with conventional and modified air injection device was considered. A modification on conventional injection device (normal air-jacket type) was carried out by changing injection angle from 90  (for conventional) to 45  and 22.5  (for modified). Continuity and one-dimensional momentum balance for the flow field with basic principle of two-phase flow and expressions of slip ratio and friction factor as function of flow rates were formulated. The analytical and experimental investigations were carried out for both conventional and unconventional air-jackets at submergence ratios 0.75, 0.6 and 0.5 and air mass flow rate from 0.5 to 97kg/hr. The comparison between the analytical and experimental results shows agreement and the main results showed that the performance and maximum efficiency of airlift pump is increased for higher mass flow rate of injected air for all tested submergence ratio using unconventional air-jacket and the higher performance was associated with injection angle 22.5 , with average enhancement were 9% and 10% for performance and maximum efficiency respectively.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 30 2023
Journal Name
Al-mustansiriyah Journal Of Science
Seasonal Optimum Tilt Angle of Solar Panels for 100 Cities in the World
...Show More Authors

Solar energy is the most abundant renewable energy source. This energy can be converted directly into electricity using solar panels. The fixed tilt solar panels are the most practical and the most widely installed throughout the world. Optimum tilt angle calculation has the advantage that it does not use expensive solar trackers. This research calculates the seasonal optimum tilt angle of solar panels for 17 cities in Iraq and 83 cities in 83 countries distributed around the world. Solar Panel Angle Calculator program was used in calculating the optimum tilt angles from vertical. The optimum tilt angle varies between 6° and 112° throughout the year. This angle for winter, spring/ autumn and summer seasons are found to be between

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Thu Oct 15 2015
Journal Name
International Journal Of Computer Applications
Experimental Investigation for Small Horizontal Portable Wind Turbine of Different Blades Profiles under Laboratory Conditions
...Show More Authors

Experimental investigation for small horizontal portable wind turbine (SHPWT) of NACA-44, BP-44, and NACA-63, BP-63 profiles under laboratory conditions at different wind velocity range of (3.7-5.8 m/s) achieved in present work. Experimental data tabulated for 2, 3, 4, and 6- bladed rotor of both profiles within range of blade pitch angles . A mathematical model formulated and computer Code for MATLAB software developed. The least-squares regression is used to fit experimental data. As the majority of previous works have been presented for large scale wind turbines, the aims were to present the performance of (SHPWT) and also to make a comparisons between both profiles to conclude which is the best performance. The overall efficiency and el

... Show More
View Publication
Crossref
Publication Date
Wed Mar 13 2019
Journal Name
Al-khwarizmi Engineering Journal
Investigation the Effect of Process Variables on the Formability of Parts Processed by Single Point Incremental Forming
...Show More Authors

Incremental sheet metal forming process is an advanced flexible manufacturing process to produce various 3D products without using dedicated tool as in conventional metal forming. There are a lot of process parameters that have effect on this process, studying the effect of some parameters on the strain distributions of the product over the length of deformation is the aim of this study.

In order to achieve this goal, three factors (tool forming shape, feed rate and incremental step size) are examined depending on three levels on the strain distributions over the wall of the product. Strain measurement was accomplished by using image processing technique using MATALB program. The significance of the control factors are explored u

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
The Effect of Fin Design on Thermal Performance of Heat Sink
...Show More Authors

      An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
Experimental study on performance of laterally loaded plumb and battered piles in layered sand
...Show More Authors

       This study introduces a series of single and pile group model tests subjected to lateral loads in . multilayered sand from Karbala, Iraq. The aim of this study is to investigate: the performance of the pile groups subjected to lateral loads; in which the pile batter inclination angle is changed; the effect of pile spacing (s/d) ratio, the influence of using different number of piles and pile group configuration. Results revealed that the performance of single negative (Reverse) Battered piles with inclination of 10° and 20° show a gain of 32% and 76 % in the ultimate lateral capacity over the regular ones. For pile groups, the use of a combination of regular, negative and positive battered piles in

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2021
Journal Name
Applied Thermal Engineering
Investigation on the combustion and performance characteristics of a DI free piston linear generator engine fuelled with CNG-CO2 blend
...Show More Authors

View Publication
Scopus (19)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The effect of the dimensions of the strategic lens on achieving tax pioneer performance: Practical research in the General Authority for Taxes
...Show More Authors

The aim of the research is to shed light on the dimensions of the strategic lens and its impact on achieving the pioneer tax performance and represented by the dimensions (strategic direction, growth, pilot indicator, renewal and modernization, efficiency and effectiveness) in the General Tax Authority. The questionnaire was adopted as a tool to collect data and information from the adult sample They are (91) who are on the site (Assistant Director General, Head of Division, First Division Deputy, Second Division Deputy, Division Officer, Division Officer Associate) The statistical program (SPSS) has been used to calculate (the mean, the standard deviation, the correlation coefficient, the difference coefficient, the F test, the

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Experimental Investigation into the Heat and Mass Transfer in an Indirect Contact Closed Circuit Cooling Tower
...Show More Authors

The heat and mass transfer coefficients of the indirect contact closed circuit cooling tower, ICCCCT, were investigated experimentally. Different experiments were conducted involving the controlling parameters such as air velocity, spray water to air mass flow rate ratio, spray water flow rate, ambient air wet bulb temperature and the provided heat load to investigate their effects on the performance of the ICCCCT. Also the effect of using packing on the performance of the ICCCCT was investigated. It was noticed that these parameters affect the tower performance and the use of packing materials is a good approach to enhance the performance for different operational conditions. Correlations for mass and heat transfer coefficients are pres

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
Cross Dipole Antennas Solution for Angle of Arrival Estimation
...Show More Authors

The Multiple Signal Classification (MUSIC) algorithm is the most popular algorithm to estimate the Angle of Arrival (AOA) of the received signals. The analysis of this algorithm (MUSIC) with typical array antenna element ( ) shows that there are two false direction indication in the plan
aligned with the axis of the array. In this paper a suggested modification on array system is proposed by using two perpendiculars crossed dipole array antenna in spite of one array antenna. The suggested modification does not affect the AOA estimation algorithm. The simulation and results shows that the proposed solution overcomes the MUSIC problem without any effect on the performance of the system.

View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of the Effect of Fuel Type on the Emitted Emissions from SIE at Idle Period
...Show More Authors

The present study investigated the impact of fuel kind on the emitted emissions at the idling period. Three types of available fuels in Iraq were tested. The tests conducted on ordinary gasoline with an octane number of 82, premium gasoline with an octane number of 92, and M20 (consist of 20% methanol and 80% regular gasoline). The 2 liters Mercedes-Benz engine was used in the experiments.

The results showed that engine operation at idle speed emits high levels of CO, CO2, HC, NOx and noise. The produced emission levels depend highly on fuel type. The premium gasoline (ON=92) represents the lower emissions level except for noise at all idling speed. Adding methanol to ordinary gasoline (ON=82) showed high levels of emi

... Show More
View Publication Preview PDF
Crossref (2)
Crossref