Microbial fuel cell is a device that uses the microorganism metabolism for the production of electricity under specific operating conditions. Double chamber microbial fuel cell was tested for the use of two cheap electrode materials copper and aluminum for the production of electricity under different operating conditions. The investigated conditions were concentration of microorganism (yeast) (0.5- 2 g/l), solutions temperature (33-45 oC) and concentration of glucose as a substrate (1.5- 6 g/l). The results demonstrated that copper electrode exhibit good performance while the performance of aluminum is poor. The electricity is generated with and without the addition of substrate. Addition of glucose substrate up to 3 g/l increased the produced current but with further increase of the amount of substrate, the current generated decreases. The optimum temperature for electricity production was found to be 36 oC.
The insulation system of a machine coil includes several layers made of materials with different characteristics. The effective insulation design of machine coils, especially in the machine end winding, depends upon an accurate model of the stress grading system. This paper proposes a modeling approach to predict the transient overvoltage, electric field, and heat generation in machine coils with a stress grading system, considering the variation of physical properties in the insulation layers. A non-uniform line model is used to divide the coil in different segments based on material properties and lengths: overhang, stress grading and slot. The cascaded connection of chain matrices is used to connect segments for the representation of the
... Show MoreThis study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p
... Show MoreThis paper presents the non-linear finite element method to study the behavior of four reinforced rectangular concrete MD beams with web circular openings tested under two-point load. The numerical finite elements methods have been used in a much more practical way to achieve approximate solutions for more complex problems. The ABAQUS /CAE is chosen to explore the behavior of MD beams. This paper also studies, the effect of both size and shape of the circular apertures of MD beams. The strengthening technique that used in this paper is externally strengthening using CFRP around the opening in the MD beams. The numerical results were compared to the experimental results in terms of ultimate load failure and displace
... Show More<span>Distributed denial-of-service (DDoS) attack is bluster to network security that purpose at exhausted the networks with malicious traffic. Although several techniques have been designed for DDoS attack detection, intrusion detection system (IDS) It has a great role in protecting the network system and has the ability to collect and analyze data from various network sources to discover any unauthorized access. The goal of IDS is to detect malicious traffic and defend the system against any fraudulent activity or illegal traffic. Therefore, IDS monitors outgoing and incoming network traffic. This paper contains a based intrusion detection system for DDoS attack, and has the ability to detect the attack intelligently, dynami
... Show MoreThis paper presents a vibration suppression control design of cantilever beam using two piezoelectric patches. One patch was used as an actuator element, while the other was used as a sensor. The controller design was designed via the balance realization reduction method to elect the reduced order model that is most controllable and observable. the sliding mode observer was designed to estimate six states from the reduced order model but three states are only used in the control law. Estimating a number of states larger than that used is in order to increase the estimation accuracy. Moreover, the state estimation error is proved bounded. An optimal LQR controller is designed then using the estimated states with the slid
... Show MoreThe current study includes (130) T2DM patients (group P) [51 males and 79 females with an ages range (35 to 55) and ages mean 49.89 years], they are sub-grouped into three categories according to their HbA1c value. patients with HbA1c less than 7 are considered as good controlled diabetic patients (30 patients) (group P1), while patients with HbA1c between 7 and 8 are considered as medium controlled diabetic patients (40 patients) (group P2), and the patient whom their HbA1c more than 8 are considered as uncontrolled diabetic patients (50 patients) (group P3). The patients group results are compared to control healthy subjects (35 subjects) (group C) [14 males and 21 Females with age range 45.51 years] matched for age, gender and BMI wer
... Show MoreField trial was conducted during the growing season of 2011-2012 at the Research
Field, Department of Biology, College of Science, Baghdad University to test the
performance of wheat cv Rabyaa, Latifiya, Al-Iraq, Tummose 2, Abu-Graib 3, IPA
99 and Sham 6 grown under different soil water deficit stresses. Several agronomic
and physiological traits and yield and yield components of the test cultivars were
determined. The experiment was conducted in split plot design with five replications
for each treatment. The cultivars were kept in the sub plot while water stress
treatment was assigned as main plot. Water stress was applied by irrigated the plots
to the soil field capacity (FC) then withheld next irrigation until
Accurate calculation of transient overvoltages and dielectric stresses from fast-front excitations is required to obtain an optimal dielectric design of power components subjected to these conditions, which are commonly due to switching and lightning, as well as utilization of power-electronic devices. Toroidal transformers are generally used at the low voltage level. However, recent investigations and developments have explored their use at the medium voltage level. This paper analyzes the model-based improvement of the insulation design of medium voltage toroidal transformers. Lumped and distributed parameter models are used and compared to predict the transient response and dielectric stress along the transformer winding. The parameters
... Show MoreThis research focuses on the removal and adsorption of Fe (III) ion using a low cost commercial polyacrylic acid hydrogel beads as adsorbent. The effects of time, initial concentration and pH on the metal ion adsorption capacity were investigated. The regeneration of the hydrogel bead and recovery of the metal ion adsorbed were study. The adsorption isotherm models were applied on experimental data and it is shown that the Langmuir model was the best one for Fe (III) ion removal. The maximum capacity was calculated. First-order and second- order kinetic models were used and it is shown that the experimental data was in reliable compliance with the first- order model with R2 value of (0.9935, 0.9011, 0.9695, 0.9912) for all concentrations
... Show MoreBackground : The contribution of diastolic dysfunction in patients with preserved left ventricular (LV) systolic function to impaired functional status and cardiac mortality in myocardial infarction (MI) is unknown.
Materials and Methods : Assessment of LV diastolic function was performed by Doppler analysis of the mitral and pulmonary venous flow and the propagation velocity of early mitral flow by color M-mode Doppler echocardiography in 150 consecutive patients at day 5-7 following their first acute MI.
Results : Patients were classified into four groups: group A: preserved LV systolic and diastolic function (n=59); group B: LV systolic dysfunction with preserved diastolic function (n=8); group C: LV diastolic dysfunction with