Preferred Language
Articles
/
joe-1103
Removal of Acidic Dye from Aqueous Solution Using Surfactant Modified Bentonite (Organoclay): Batch and Kinetic Study
...Show More Authors

Modified bentonite has been used as effective sorbent material for the removal of acidic dye (methyl orange) from aqueous solution in batch system. The natural bentonite has been modified using cationic surfactant (cetyltrimethyl ammonium bromide) in order to obtain an efficient sorbent through converting the properties of bentonite from hydrophilic to organophilic. The characteristics of the natural and modified bentonite were examined through several analyses such as Scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and Surface area. The batch study was provided the maximum dye removal efficiency of 88.75 % with a sorption capacity of 555.56 mg/g at specified conditions (150 min, pH= 2, 250 rpm, and 0.5 g/100 ml). The-results-showed that with the Freundlich isotherm model the sorption data was accurately described with (R2≥0.94) in comparison with the Langmuir model under the studied conditions. The kinetic studies were revealed that the sorption follows a pseudo-second-order kinetic model which indicates chemisorption between sorbent and sorbate molecules. 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Engineering
Statistical analysis of the removal of Chromium(VI)by Iron Oxide Nanoparticle (Fe3O4)
...Show More Authors

Investigation of the adsorption of Chromium (VI) on Fe3O4 is carried out using batch scale experiments according to statistical design using a software program minitab17 (Box-Behnken design). Experiments were carried out as per Box-Behnken design with four input parameters such as pH (2-8), initial concentration (50–150mg/L), adsorbent dosage (0.05–0.3 g) and time of adsorption (10–60min). The better conditions were showed at pH: 2; contact time: 60 min; chromium concentration: 50 mg/L and magnetite dosage: 0.3 g for maximum Chromium (VI) removal of (98.95%) with an error of 1.08%. The three models (Freundlich, Langmuir, and Temkin) were fitted to experimental data, Langmuir isotherm has bette

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis
...Show More Authors

Abstract Background: One of the most important methods to replace lost teeth is dental implants. In order to increase the strength of connection of the implant with the jaw bone to provide early loading after placement, implant is coated by different coating materials that achieved that purpose. The aim of this study was to evaluate the influence of coating CP Ti implant with calcium carbonate on the strength of bone-implant interface after two and six weeks of implantation in rabbit femur bone by torque removal test, histological and histomorphometric analysis. Materials and methods: Coating the surface of commercially pure titanium screws with extra pure synthetic calcium carbonate via electrophoretic deposition method (EPD) was done. The

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Feb 05 2023
Journal Name
Engineering, Technology & Applied Science Research
Performance Evaluation of Emulsion Liquid Membrane on Chlorpyrifos Pesticide Removal: Stability, Mass Transfer Coefficient, and Extraction Efficiency Studies
...Show More Authors

Emulsion Liquid Membrane (ELM) is an emerging technology that removes contaminants from water and industrial wastewater. This study investigated the stability and extraction efficiency of ELM for the removal of Chlorpyrifos Pesticide (CP) from wastewater. The stability was studied in terms of emulsion breakage. The proposed ELM included n-hexane as a diluent, span-80 as a surfactant, and hydrochloric acid (HCl) as a stripping agent. Parameters such as mixing speed, aqueous feed solution pH, internal-to-organic membrane volume ratio, and external-to-emulsion volume ratio were investigated. A minimum emulsion breakage of 0.66% coupled with a maximum chlorpyrifos extraction and stripping efficiency were achieved at 96.1% and 95.7% at b

... Show More
Crossref (7)
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Petroleum Science And Engineering
Operation of a MEG pilot regeneration system for organic acid and alkalinity removal during MDEA to FFCI switchover
...Show More Authors

View Publication
Scopus (15)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Tue Sep 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
EFFECT OF TEMPERATURE ON CORROSION OF CARBON STEEL BOILER TUBES IN DILUTE SODUIM CHLORIDE SOLUTION
...Show More Authors

The corrosion behavior of carbon steel at different Temperatures and in water containing different sodium chloride
concentrations under 3 bar pressure has been investigated using weight loss method . The carbon steel specimens were
immersed in water containing (100,400,700,1000PPM) of NaCl solution and under temperature was increased from
(90-120ºC) under pressures of 3 bar. The results of this investigation indicated that corrosion rate increased with NaCl
concentrations and Temperature.

View Publication Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Finite Element Based Solution of Laplace's Equation Applied to Electrical Activity of the Human Body
...Show More Authors

Computer models are used in the study of electrocardiography to provide insight into physiological phenomena that are difficult to measure in the lab or in a clinical environment.

The electrocardiogram is an important tool for the clinician in that it changes characteristically in a number of pathological conditions. Many illnesses can be detected by this measurement. By simulating the electrical activity of the heart one obtains a quantitative relationship between the electrocardiogram and different anomalies.

Because of the inhomogeneous fibrous structure of the heart and the irregular geometries of the body, finite element method is used for studying the electrical properties of the heart.

This work describes t

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 04 2018
Journal Name
Al-khwarizmi Engineering Journal
Modified Elman Neural-PID Controller Design for DC-DC Buck Converter System Based on Dolphin Echolocation Optimization
...Show More Authors

This paper describes a new proposed structure of the Proportional Integral Derivative (PID) controller based on modified Elman neural network for the DC-DC buck converter system which is used in battery operation of the portable devices. The Dolphin Echolocation Optimization (DEO) algorithm is considered as a perfect on-line tuning technique therefore, it was used for tuning and obtaining the parameters of the modified Elman neural-PID controller to avoid the local minimum problem during learning the proposed controller. Simulation results show that the best weight parameters of the proposed controller, which are taken from the DEO, lead to find the best action and unsaturated state that will stabilize the Buck converter system performan

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Engineering Analysis With Boundary Elements
Numerical solution of two-dimensional mixed problems with variable coefficients by the boundary-domain integral and integro-differential equation methods
...Show More Authors

View Publication
Crossref (11)
Crossref
Publication Date
Sat Jan 25 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Bioactivity of Gutta flow II versus Modified Gutta Percha based Silicon Endodontic Sealers by Nanobioactive Fillers
...Show More Authors

The success of endodontic therapy is relied on radicular system cleaning, shaping, elimination of micro-organisms, and three dimensional filling of the radicular complex.This study was conducted to develop and assess new root canal sealer incorporating nano-sized bioactive glass into Gutta Flow II. The following concentration was used depend on a pilot study included adding (3%) of 45S5 bioactive glass into the Gutta Flow II. These materials were tested through assessment bioactivity. bioactivity test was undertaken after immersion of the tested samples into PBS for three days, seven days, fourteen days, and twenty eight days using FTIR too. study was found that it’s peaks was appear at level 800-1000 cm-1. The results showed that GFII gr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Develop Bactra system to determine Mutagens in the Environment, Food / IV modified Mutagens use of hydroxylamine
...Show More Authors

Use Almtafr axis to study the response component that isolates gave a positive response to the use of standard Almtafr which leads to lower the temperature and the number of cells at a temperature suitable Rifampicin resistant less than that TJ and similarly reflected on the frequency of mutations induced

View Publication Preview PDF