Preferred Language
Articles
/
joe-1078
Prediction of Heat Transfer Coefficient and Pressure Drop in Wire Heat Exchanger Working with R-134a and R-600a
...Show More Authors

An experimental and theoretical works were carried out to model the wire condenser in the domestic refrigerator by calculating the heat transfer coefficient and pressure drop and finding the optimum performance. The two methods were used for calculation, zone method, and an integral method. The work was conducted by using two wire condensers with equal length but different in tube diameters, two refrigerants, R-134a and R-600a, and two different compressors matching the refrigerant type. In the experimental work, the optimum charge was found for the refrigerator according to ASHRAE recommendation. Then, the tests were done at 32˚C ambient temperature in a closed room with dimension (2m*2m*3m). The results showed that the average heat transfer coefficient for the R-600a was higher than the R-134a, so the length of the wire tube was longer with R-134a than R-600a. The pressure drop for the smaller tube diameter was higher than the other tube. The second law thermodynamic efficiency was higher for R-600a, which reached 41%.  The entropy generation minimization analysis showed that the R-600a refrigerant type and smaller tube diameter are approached the optimum point.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 06 2004
Journal Name
Iraqi Journal Of Science
Cluster and factor analyses R and Q mode technique of geochemical and petrological data of the Shalair Metamorphic Rock Group, Shalair Valley area, Northeastern Iraq
...Show More Authors

Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Visibal management and its implications for Organizational culture A survey of a sample of R & D staff / Ministry of Higher Education and Scientific Research
...Show More Authors

The research aims to shed light on the concept of Visibal management and its reflection on the organizational culture of the organization. The visual administration is a modern administrative method that contributes to the renewal and development of the organization's reality through surveying the opinions of a sample of 61 employees in the R & D / Ministry of Higher Education and Scientific Research. (130) individuals. The questionnaire was used as a main tool for collecting data and information, and their answers were analyzed using the SPSS program in data entry and analysis. The most important tools are computational circles, standard deviations, method of analysis and regression equation. There is a possibility to apply

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Physics: Conference Series
The combined effectiveness of magnetic force and heat\mass transfer on peristaltic transportation “Hyperbolic Tangent” Nanofluid in a Slopping Non-Regular Non-symmetric Channel.
...Show More Authors
Abstract<p>in the present article, we present the peristaltic motion of “Hyperbolic Tangent nanofluid” by a porous area in a two dimensional non-regular a symmetric channel with an inclination under the impact of inclination angle under the impact of inclined magnetic force, the convection conditions of “heat and mass transfer” will be showed. The matter of the paper will be further simplified with the assumptions of long wave length and less “Reynolds number”. we are solved the coupled non-linear equations by using technical analysis of “Regular perturbation method” of series solutions. We are worked out the basic equations of continuity, motion, temperature, and volume fraction</p> ... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue May 01 2018
Journal Name
Chemical Engineering And Processing - Process Intensification
Studies of mass transfer at a spiral-wound woven wire mesh rotating cylinder electrode
...Show More Authors

Mass transfer has been studied at rotating cylinder electrodes fabricated with spiral-wound woven-wire meshes using reduction of copper as a test reaction. The experimental data were correlated by an empirical expression between the Sherwood number and the Reynolds number, both regarding the hydraulic diameter as a characteristic length. It was found that the Sherwood number was dependent upon the Reynolds number to the power of 0.521. An enhancement factor was adopted to compare the efficiency of the new rotating cylinder electrode with previous three-dimensional rotating cylinder electrodes. The results showed that the new type has a mass-transfer enhancement factor 2.3 times higher than those obtained with smooth rotating cylinder electr

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Thu Dec 28 2017
Journal Name
Al-khwarizmi Engineering Journal
Simulation Study of Mass Transfer Coefficient in Slurry Bubble Column Reactor Using Neural Network
...Show More Authors

 

The objective of this study was to develop neural network algorithm, (Multilayer Perceptron), based correlations for the prediction overall volumetric mass-transfer coefficient (kLa), in slurry bubble column for gas-liquid-solid systems. The Multilayer Perceptron is a novel technique based on the feature generation approach using back propagation neural network. Measurements of overall volumetric mass transfer coefficient were made with the air - Water, air - Glycerin and air - Alcohol systems as the liquid phase in bubble column of 0.15 m diameter. For operation with gas velocity in the range 0-20 cm/sec, the overall volumetric mass transfer coefficient was found to decrease w

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Heat Transfer
A tubular solar still integrated with a heat pipe
...Show More Authors
Abstract<p>The aim of this work is to explore the thermal performance of a tracked tubular solar still (TSS) with a parabolic trough concentrator in Baghdad (33.27° N, 44.37° E) in September 2022. The present tubular still is distinguished by its hexagonal glass cover. The effect of integrating the TSS with a heat pipe, the still tilt angle (10°, 15°), and the depth of saline water inside the still partitions on the productivity of freshwater are investigated. The results showed that using heat pipe enhances the freshwater productivity by 25%–40% and the efficiency by 25%. For the still integrated with heat pipe, as the water depth is increased from 5.5 to 6.5 cm the productivity of freshwater is incre</p> ... Show More
View Publication
Scopus (16)
Crossref (8)
Scopus Crossref
Publication Date
Sun Mar 01 2026
Journal Name
Journal Of Engineering
Heat Dissipation Performance of High-Power CPUs using Finned Copper Foam Heat Sinks
...Show More Authors

Thermal management has become a major issue in the latest high performance computing machines because high CPU temperatures result in inefficient performance and decreased hardware life span. In this work, the cooling performance of a finned metal foam heat sink (FMFHS) was examined. The pore density values of tested copper metal foam (CMF) samples with different values of PPI 5, 10 and 20, with a constant porosity of 90%. For reference, these samples were measured by a conventional Aluminum plate-fin heat sink (CHS). The work was performed under experimental conditions in which air directed over the heat sink surface at air velocities (2.5, 3.0 and 3.5 m/s). The environmental temperature was fixed at 27 °C. Findings

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Oct 14 2016
Journal Name
International Journal For Computational Methods In Engineering Science And Mechanics
Simultaneous determination of time-dependent coefficients and heat source
...Show More Authors

View Publication
Scopus (18)
Crossref (15)
Scopus Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Mass Transfer Coefficient During Cathodic Protection of Low Carbon Steel in Seawater
...Show More Authors

The aim of this research is to calculate mass transfer coefficient, kd, during cathodic protection of low carbon steel in neutral seawater (3.5% W/V NaCl in distilled water with pH = 7). Two types of cathodic protection were used:

First: Sacrificial anode cathodic protection (SACP) were a pipeline of steel carrying seawater  using zinc as a sacrificial anode and with variable temperatures ranged (0 – 45oC) and volumetric flow rate ranged (5 – 900 lit/hr). It was found that the kd increases with increasing temperature and volumetric flow rate of seawater, where kd ranged (0.24×10-6 – 41.6×10-6 m/s).

Second: Impressed current cathodic pr

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Thermal Analysis And Calorimetry
Heat transfer and fluid flow characteristics over a backward-facing step (BFS) containing square-rectangular ribs integrated as forward-facing steps (FFS)
...Show More Authors

View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref