Preferred Language
Articles
/
joe-1048
Effect of laser process an inclined surface cutting of mild steel then analysis data statistically by RSM
...Show More Authors

The regression analysis process is used to study and predicate the surface response by using the design of experiment (DOE) as well as roughness calculation through developing a mathematical model. In this study; response surface methodology and the particular solution technique are used. Design of experiment used a series of the structured statistical analytic approach to investigate the relationship between some parameters and their responses. Surface roughness is one of the important parameters which play an important role. Also, its found that the cutting speed can result in small effects on surface roughness. This work is focusing on all considerations to make interaction between the parameters (position of influence) because laser power directly depends on cutting speed with high gas pressure and vice versa to obtain a less surface roughness. Data analysis showed that the lower value for roughness was (0.68) µm and the high roughness was (8.56) µm.  The model values for considered fit are suggested to be as (R2) = 51.76%. The selected coefficient is referred to the amount of model variation in the response. The adjusted value of (R2) = 8.34% will calculate the number of forecasting model and is normally useful for comparing models with different numbers of predictions. The (F) test is used to determine whether interaction and major effects are significant. The p-value is the probability of obtaining a statistic test which is considered as the extreme of actual calculated values if the null hypothesis is true. A commonly cut-off value that used for the p-value is (0.05). This value is used to be the active contribution to investigate the correlation between laser machining parameter with the surface roughness. Also the goal of this research highlights the experimental control parameters of mild steel laser processing with their responses.

 

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Desalination And Water Treatment
Optimization and kinetic evaluation of reactive yellow dye degradation by solar photocatalytic process
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect of Shot Peening on Fatigue Properties for Corroded and Uncorroded (CK35) Steel
...Show More Authors

The traction property is one of the important mechanical properties, especially the rotary parts which are subjected to constant and variable loads There are many methods used to improve this property, and the shoot peening by metal balls is considered the most critical one. the study focuses on this characteristic of steel CK35 used in many engineering applications as the rotating shafts and railway This study shows that the fatigue strength is improved by14% after shoot peening with metal balls. The study includs the rehabilitation of damaged samples as a result of fatigue corrosion. The standard solution adopted was 36% MgCl­2 with a 30 days immersion period. These samples has been improved by 6% after it decreased by18% d

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 20 2025
Journal Name
International Journal Of Advanced Research In Computer Science
IMPROVE DATA ENCRYPTION BY USING DIFFIE-HELLMAN AND DNA ALGORITHMS, AUTHENTICATED BY HMAC-HASH256
...Show More Authors

: The need for means of transmitting data in a confidential and secure manner has become one of the most important subjects in the world of communications. Therefore, the search began for what would achieve not only the confidentiality of information sent through means of communication, but also high speed of transmission and minimal energy consumption, Thus, the encryption technology using DNA was developed which fulfills all these requirements [1]. The system proposes to achieve high protection of data sent over the Internet by applying the following objectives: 1. The message is encrypted using one of the DNA methods with a key generated by the Diffie-Hellman Ephemeral algorithm, part of this key is secret and this makes the pro

... Show More
View Publication
Crossref
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Effect of Temperature on Reliability and Degradation of 0.63?m Laser Diode
...Show More Authors

The reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Theoretical Study of The Heating Effect of Laser Radiations on SiUcaGlass Systems
...Show More Authors

A theoretical study has been proposed to investigate the effects of different laser radiations (Nd - glass, DF and C02) as a heating source on different glass samples (Optical glass, Bk - 7 and Soda - lime glass) and different waves lengths (10.6, 3.8, 1.6) ???. The heat changes as which are resulted due irradiation with laser sources have been determined by using the one dimension mathematical relation as a function of time (t) and depth (z). The results of the study show ed that the irradiation with C02 laser had a greater effect than DF laser, while the effects of Nd - glass laser were minimal with a power density of (1.8*10?? w/m2) within atime(l^sec).(Forboth Kinds) The change in the temperatures were not exceeded than (70"K) in all sa

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Effect of Thermocycling on Surface Roughness and Shear Bond Strength of Acrylic Soft Liner to the Surface of Thermoplastic Acrylic Treated with Ethyl Acetate
...Show More Authors

Objective: To enhance bonding strength between thermoplastic denture base and acrylic soft liner through ethyl acetate surface treatment. Materials and Methods: Modifications of thermoplastic acrylic denture base surface were investigated with SEM. FTIR was used to detect whether there was a chemical bond between thermoplastic acrylic and the organic solvent. A total of 80 samples were prepared and divided into 20 samples for the surface roughness test and 60 samples for the shear bond strength test. Failure type was assessed visually. Results: Shear bond strength and surface roughness values of un treated samples were lower in comparison to surface treated groups; the greatest post thermocycling bond strength value was recorded for the sam

... Show More
Preview PDF
Publication Date
Sun Sep 27 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Histomorphometric analysis of bone deposition at Ti implant surface dip-coated with hydroxyapatite (In vivo study)
...Show More Authors

Background: Synthetic hydroxyapatite,(Ca10(PO4)6(OH2) can directly bond to bones without infection and fibrous encapsulation, thus is regarded as bioactive and biocompatible. The aim of the study was the estimation of microarchitecture bone parameters include bone mass (gm/cm2) cortical bone width (mm), thread width (mm), marrow space star volume analysis (V*m) and osteoblast, osteocyte cell number. Materials and methods: Ninety-six (96) commercially pure titanium CpTi) used in this study, (48) implants were coated with HA by dipping coating and (48) implants were used as control. They were inserted in (32) Newzland white rabbits and followed for 2 & 6 weeks. Mechanical torque removal test and histomorphometric analysis of bone microarchit

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Optical Materials
Design and analysis of a high sensitivity open microchannel PCF-based surface plasmon resonance refractometric sensor
...Show More Authors

View Publication
Scopus (33)
Crossref (36)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Effect of Laser Energy and Repetition Rate on Holmium Plasma Emission
...Show More Authors

The holmium plasma induced by a 1064-nmQ-switched Nd:YAG laser in air was investigated. This work was done theoretically and experimentally.  Cowan code was used to get the emission spectra for different transition of the holmium target. In the experimental work, the evolution of the plasma was studied by acquiring spectral images at different laser pulse energies (600,650,700, 750, and 800 mJ). The repetition rates of (1Hz and 10Hz) in the UV region (200-400 nm). The results indicate that, the emission line intensities increase with increasing of the laser pulse energy and repetition rate. The strongest emission spectra appeared when the laser pulse energy is 800mJ and 10 Hz repetition rate at λ= 345.64nm, with the maximum intensi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Gamma Ray Effect on the Properties of Coumarin C47 Laser Dye
...Show More Authors

The research is concerned about studying the absorption spectrum of the solution coumarin dye C47. The chloroform solvent was used with C47 dye in three different concentrations 10-4, 10-5 and 10-6 M. The laser dye solution was prepared by dissolving the required amount of dye in chloroform alcohol, while studying absorption spectrum before and after irradiation with gamma ray by cobalt-60 source 60Co at exposure time, which are 0, 4, 6 and 18 hours with different absorbed doses 0, 136, 204 and 612 Gy. The results show that red shift in the absorption spectrum was increased by increasing the concentration of laser dye solutions , while the increase of gamma dose led to increase the red shift after irradiation, as the exposure period and irr

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref