Preferred Language
Articles
/
joe-1041
Removal of Dissolved Organic Compounds and Contaminants from Wastewater of a Petroleum Refinery by Ion Exchange
...Show More Authors

The efficient removal of dissolved organic compounds (DOC) from wastewater has become a major environmental concern because of its high toxicity even at low concentrations. Therefore, a technique was needed to reduce these pollutants. Ion exchange technology (IE) was used with AmberliteTM IR120 Na, AmberliteTM IR96RF, and AmberliteTM IR402, firstly by using anion and mixed bed system, where the following variables are investigated for the process of adsorption: The height of the bed in column (8,10 and 14 cm), different concentrations of (DOC) content at constant flow rate. The use of an ion exchanger unit (continuous system) with three columns (cation, anion, and mixed bed) was studied. The effect of the following variables, such as a change in temperatures (23,30 and 40 Co) and the change in flow rate (2,4,6 L/min) was studied. The results showed that the adsorption capacity decreased with increasing the flow rate. The linear equation models of (Langmuir, Freundlich, Timken, and Dubinin-Radushkevich) were used. The results were analyzed using three known models for equilibrium and temperature constant. Graphically, the Langmuir model was the most consistent with the adsorption results because it has the highest adsorption capacity and the highest correlation value of R2 = 0.97. The ion exchange column dynamics were studied using models such as (Thomas model). The results showed that the experimental results were well correlated with the model equations. While the tests showed that the removal rate of pollutants was up to 90% for organic compounds.

 

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Study of Electrodialysis for Treatment Fuel Washing Wastewater
...Show More Authors

In this work, electrodialysis (ED) has been demonstrated to be appropriate technique for reducing the electrical conductivity of real wastewater from fuel washing unit, which has been previously treated by other electrochemical technology (electrocoagulation and electrooxidation).  A five cell electrodialysis stack, with an active membrane area of 60 cm2 per cell was employed. During a batch recirculation mode ED system, the effects of parameters such as electrical potential applied (6-18 V) and flow rate of streams (0.5-1.7 L/min.) on the performance of the total dissolved solids (TDS) separation and specific power consumption (SPC) were studied. The results indicate that the process of ED under potential (15 V) and flow

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 27 2026
Journal Name
Sustainability
Recent Developments in Membrane, Adsorption, and Electrochemical Sustainable Approaches for Cadmium Removal from Contaminated Water
...Show More Authors

The issue of cadmium (Cd(II)) contamination of the water is a serious concern of the environmental and health problem, and this requires effective technology to remove the problem of toxic element. It is the purpose of this review paper to give an overview of several techniques of cadmium removal, such as polymer membranes and composites, adsorption using green materials, and electrochemical methods. The important conclusions are presented regarding the effectiveness of the polymer and composite membranes; e.g., the efficacy of the PES/HPEI-SH membrane that reached 99% removal of Cd(II) in 20 min with adsorption capacity of 135.59 mg/cm2, and the PVA/IC/PANI/GO nanofiber composite that indicates high adsorption of the 459 mg/g. The

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Thu Jun 10 2021
Journal Name
Neuroquantology
Direct Yellow 8 Azo Removal by Bentonite Clay Solution: Experimental and Theoretical Studies
...Show More Authors

In the theoretical part, removal of direct yellow 8 (DY8) from water solution was accomplished using Bentonite Clay as an adsorbent. Under batch adsorption, the adsorption was observed as a function of contact time, adsorbent dosage, pH, and temperature. The equilibrium data were fitted with the Langmuir and Freundlich adsorption models, and the linear regression coefficient R2 was used to determine the best fitting isotherm model. thermodynamic parameters of the ongoing adsorption mechanism, such as Gibb's free energy, enthalpy, and entropy, have also been measured. The batch method was also used for the kinetic calculations, and the day's adsorption assumes first-order rate kinetics. The kinetic studies also show that the intrapar

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Oct 16 2020
Journal Name
Int J Energy Res
Structural, electronic and optoelectronic properties of AB5C8 (A = Cu/Ag; B = In and C = S, Se and Te) compounds
...Show More Authors

Ternary semiconductors AB5C8 (A = Cu/Ag, B = In and C = S, Se or Te) have been investigated. The CuIn5S8 and AgIn5S8 have been synthesize in cubic spinel structure with space group (Fd3m), whereas CuIn5Se8, AgIn5Se8, CuIn5Te8 and AgIn5Te8 have tetragonal structures with space group P-42m. The relaxed crystal geometry, electrical properties such as electronic band structure and optoelectronic properties are predicted by using full potential method in this work. For the determination of relaxed crystal geometry, the gradient approximation (PBE-GGA) is used. All the studied compounds are semiconductors based on their band structures in agreement with the experimental results, and their bulk moduli are in the range 35 to 69 GPa. Wide absorption

... Show More
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of Engineering
A comparative Isothermal and Kinetic Study of the Adsorption of Lead (II) from Solution by Activated Carbon and Bentonite
...Show More Authors

This work is aiming to study and compare the removal of lead (II) from simulated wastewater by activated carbon and bentonite as adsorbents with particle size of 0.32-0.5 mm. A mathematical model was applied to describe the mass transfer kinetic.

The batch experiments were carried out to determine the adsorption isotherm constants for each adsorbent, and five isotherm models were tested to choose the best fit model for the experimental data. The pore, surface diffusion coefficients and mass transfer coefficient were found by fitting the experimental data to a theoretical model. Partial differential equations were used to describe the adsorption in the bulk and solid phases. These equations were simplified and the

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 05 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY OF OPTIMUM CONDITIONS FOR REMOVAL OF HEAVY METAL ELEMENTS BY LOCALLY ISOLATED FUNGI Aspergillus niger.: STUDY OF OPTIMUM CONDITIONS FOR REMOVAL OF HEAVY METAL ELEMENTS BY LOCALLY ISOLATED FUNGI Aspergillus niger.
...Show More Authors

The best optimum temperature for the isolate was 30○C while the pH for the maximum mineral removal was 6. The best primary mineral removal was 100mg/L, while the maximum removal for all minerals was obtained after 8 hrs, and the maximum removal efficiency was obtained after 24 hrs. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/ minute. Inoculums of 5ml/ 100ml which contained 106 cell/ ml showed maximum removal for the isolate.

View Publication Preview PDF
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
Day to Day variation of Ionosphere Electron and Ion Temperature during Great and Severe Geomagnetic Storms
...Show More Authors

The ionospheric characteristics exhibit significant variations with the solar cycle, geomagnetic conditions, seasons, latitudes and even local time. Representation of this research focused on global distribution of electron (Te) and ion temperatures (Ti) during great and severe geomagnetic storms (GMS), their daily and seasonally variation for years (2001-2013), variations of electron and ion temperature during GMS with plasma velocity and geographic latitudes. Finally comparison between observed and predicted Te and Ti get from IRI model during the two kinds of storm selected. Data from satellite Defense Meteorological Satellite Program (DMSP) 850 km altitude are taken for Te, Ti and plasma velocity for different latitudes during great

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Comparison Study for The Performance of Polyethersulfone Ultrafiltration Mixed Matrix Membranes in The Removal of Heavy Metal Ions from Aqueous Solutions
...Show More Authors

Polyethersulfone (PES) ultrafiltration membrane blending NaX zeolite crystals as a hydrophilic additive was examined for zinc (II) and lead ions Pb (II) removal from aqueous solutions. The effect of NaX zeolite content on the permeation flux and removal efficiency was studied. The results showed that adding zeolite to the polymer matrix enhanced the permeation flux. The permeation flux of all the zeolite/PES matrix membranes was higher than the pristine membrane. No significant improvement was observed in the removal of Zn (II) ions using all prepared membranes as the removal percentage did not raise above 29.2%. However, the removal percentage of Pb (II) ions was enhanced to 97% using a membrane containing 0.9%wt. zeolite. Also, it was

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Fri May 01 2026
Journal Name
The Innovation
Does petroleum resource extraction and oceanic heat transfer increase geothermal heat flux? A global multi-sensor study of oil basins
...Show More Authors

View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Iraqi Journal Of Physics
Effect of Organic / Inorganic Gate Materials on the Organic Field-Effect Transistors Performance
...Show More Authors

The choice of gate dielectric materials is fundamental for organic field effect transistors (OFET), integrated circuits, and several electronic applications. The operation of the OFET depends on two essential parameters: the insulation between the semiconductor layer and the gate electrode and the capacitance of the insulator. In this work, the electrical behavior of a pentacene-based OFET with a top contact / bottom gate was studied. Organic polyvinyl alcohol (PVA) and inorganic hafnium oxide (HfO2) were chosen as gate dielectric materials to lower the operation voltage to achieve the next generation of electronic applications. In this study, the performance of the OFET was studied using monolayer and bilayer gate insulators. To mo

... Show More
View Publication Preview PDF
Crossref