Preferred Language
Articles
/
joe-1041
Removal of Dissolved Organic Compounds and Contaminants from Wastewater of a Petroleum Refinery by Ion Exchange
...Show More Authors

The efficient removal of dissolved organic compounds (DOC) from wastewater has become a major environmental concern because of its high toxicity even at low concentrations. Therefore, a technique was needed to reduce these pollutants. Ion exchange technology (IE) was used with AmberliteTM IR120 Na, AmberliteTM IR96RF, and AmberliteTM IR402, firstly by using anion and mixed bed system, where the following variables are investigated for the process of adsorption: The height of the bed in column (8,10 and 14 cm), different concentrations of (DOC) content at constant flow rate. The use of an ion exchanger unit (continuous system) with three columns (cation, anion, and mixed bed) was studied. The effect of the following variables, such as a change in temperatures (23,30 and 40 Co) and the change in flow rate (2,4,6 L/min) was studied. The results showed that the adsorption capacity decreased with increasing the flow rate. The linear equation models of (Langmuir, Freundlich, Timken, and Dubinin-Radushkevich) were used. The results were analyzed using three known models for equilibrium and temperature constant. Graphically, the Langmuir model was the most consistent with the adsorption results because it has the highest adsorption capacity and the highest correlation value of R2 = 0.97. The ion exchange column dynamics were studied using models such as (Thomas model). The results showed that the experimental results were well correlated with the model equations. While the tests showed that the removal rate of pollutants was up to 90% for organic compounds.

 

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Iraqi Journal Of Physics
Theoretical Model for Spectroscopic Study of Cu+2, Co+2, and Fe+3 Dissolved in Ethanol with A Different Concentrations
...Show More Authors

The absorption spectrum for three types of metal ions in different concentrations has been studying experimentally and theoretically. The examination model is by Gaius model in order to find the best fitting curve and the equation controlled with this behavior. The three metal ions are (Copper chloride Cu+2, Iron chloride Fe+3, and Cobalt chloride Co+2) with different concentrations (10-4, 10-5, 10-6, 10-7) gm/m3. The spectroscopic study included UV-visible and fluorescence spectrum for all different concentrations sample. The results refer to several peaks that appear from the absorption spectrum in the high concentration of all metal ions solution.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
Removal of Malachite Green from Aqueous Solution using Ficus Benjamina Activated Carbon-Nonmetal Oxide synthesized by pyro Carbonic Acid Microwave
...Show More Authors

Activated carbon derived from Ficus Binjamina agro-waste synthesized by pyro carbonic acid microwave method and treated with silicon oxide (SiO2) was used to enhance the adsorption capability of the malachite green (MG) dye. Three factors of concentration of dye, time of mixing, and the amount of activated carbon with four levels were used to investigate their effect on the MG removal efficiency. The results show that 0.4 g/L dosage, 80 mg/L dye concentration, and 40 min adsorption duration were found as an optimum conditions for 99.13% removal efficiency. The results also reveal that Freundlich isotherm and the pseudo-second-order kinetic models were the best models to describe the equilibrium adsorption data.

 

View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Sun Aug 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Fixation of Efficient Method for Separation and Analysis of Alkyl Al koxy Silan Compounds by Gas Chromatography
...Show More Authors

       Modification of gas chromatographic technique for the separation and determination of methyl ethoy silane compounds which were synthesized by the addition of absolute ethanol to methyl chlorosilane compounds have been elaborated experimentally.  The addition of absolute dry ethanol to methyl chlorosilane compounds in the presence of a dry stream of nitrogen gas led to sweep out the liberated HCl gas. This method was found to be the suitable method for the preparation of methyl ethoxy silane compounds. The optimum parameter selected after careful and precise studies was between 20 – 30 ml \ min to carrieir gas flow rate, while applied temperatures of detector and injection part were 250 Â

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 25 2017
Journal Name
Al-khwarizmi Engineering Journal
Removal Water Turbidity by Crumb Rubber Media
...Show More Authors

Abstract

The removal of water turbidity by using crumb rubber filter was investigated .The present study was conducted to evaluate the effect of variation of influent water turbidity (10, 25 and 50 NTU), media size (0.6and 1.14mm), filtration rate (25, 45 and 65 l/hr) and bed depth (30 and 60 cm) on the performance of mono crumb rubber filter in response to the effluent filtered water turbidity and head loss development, and compare it with that of conventional sand filter.Results revealed that 25 l/hr flow rate and 25 NTU influent turbidity were the best operating conditions.  smaller media size and higher bed depth gave the best removal efficiency while higher media size and small bed depth gave lower head

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Boron Removal by Adsorption onto Different Oxides
...Show More Authors

A research was conducted to determine the feasibility of using adsorption process to remove boron from aqueous solutions using batch technique. Three adsorbent materials; magnesium, aluminum and iron oxide were investigated to find their abilities for boron removal. The effects of operational parameters on boron removal efficiency for each material were determined.
The experimental results revealed that maximum boron removal was achieved at pH 9.5 for magnesium oxide and 8 for aluminum and iron oxide. The percentage of boron adsorbed onto magnesium,aluminum and iron oxide reaches up to 90, 42.5 and 41.5% respectively under appropriate conditions. Boron concentration in effluent water after adsorption via magnesium oxide comply with th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
Organic Electronics
Patterning organic transistors by dry-etching: The double layer lithography
...Show More Authors

View Publication
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Process Optimization Study of Pb(II) Removal by Bulk Liquid Membrane (BLM)
...Show More Authors

   Box-Wilson experimental design method was employed to optimized lead ions removal efficiency by bulk liquid membrane (BLM) method. The optimization procedure was primarily based on four impartial relevant parameters: pH of feed phase (4-6), pH of stripping phase (9-11), carrier concentration TBP (5-10) %, and initial metal concentration (60-120 ppm). maximum recovery efficiency of lead ions is 83.852% was virtually done following thirty one-of-a-kind experimental runs, as exact through 24-Central Composite Design (CCD). The best values for the aforementioned four parameters, corresponding to the most restoration efficiency were: 5, 10, 7.5% (v/v), and 90 mg/l, respectively. The obtained experimental data had been

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Ibuprofen Degradation from Synthetic Wastewater Using Photo-Fenton Process
...Show More Authors

   The removal of Ibuprofen antibiotics (IBU) by photo-degradation UV/H2O2/Fe+2 system was investigated in a batch reactor under different initial concentrations of H2O2 (100-500) mg/L, Fe+2 (10-40) mg/L, pH (3-9) and initial concentrations of IBU (10-80) mg/L, and their relationship with the degradation efficiency were studied. The result demonstrated that the maximum elimination of IBU was 85.54% achieved at 300 mg/L of H2O2, 30 mg/L of Fe+2, pH=3, and irradiation time of 150 min, for 10 mg/L of IBU. The results have shown that the oxidation reagent H2O2 plays a very important role in IBU degradation.

View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sat Mar 04 2006
Journal Name
Iraqi National Journal Of Chemistry
Synthesis a new series of azo compounds containing oxadiazole rings
...Show More Authors

Some new 2,5-disubsituted-1,3,4-oxadiazole derivatives with azo group were synthesized by known reactions sequence . The structure of the synthesized compounds were confirmed by physical and spectral means .

Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Using of Constructed Wetlands in The Treatment of Wastewater: A Review for Operation and Performance: Review for Using of Constructed Wetlands in The Treatment of Wastewater: Operation and Performance
...Show More Authors

Wastewater recycling for non-potable uses has gained significant attention to mitigate the high pressure on freshwater resources. This requires using a sustainable technique to treat natural municipal wastewater as an alternative to conventional methods, especially in arid and semi-arid rural areas. One of the promising techniques applied to satisfy the objective of wastewater reuse is the constructed wetlands (CWs) which have been used extensively in most countries worldwide through the last decades. The present study introduces a significant review of the definition, classification, and components of CWs, identifying the mechanisms controlling the removal process within such units. Vertical, horizontal, and hybrid CWs

... Show More
View Publication Preview PDF
Crossref