Examination of 241 specimens of two bee-eater species, Merops apiaster and Merops
superciliosus persicus reveal recording of Haemoproteus meropis (Zagar, 1945) emend.
Bennett, 1978 and H. manwelli Bennett, 1978 for the first time in Iraq. A new species
Haemoproteus hudaidensis sp. nov. is described. Microfilariae are also infected the two host
species. The results are discussed with the pertinent literature and the necessary comparision
of morphometric measurements of the recorded parasites with that previously reported is
provided along with a taxonomic key including the newly described haemoproteid.
In this paper, a new analytical method is introduced to find the general solution of linear partial differential equations. In this method, each Laplace transform (LT) and Sumudu transform (ST) is used independently along with canonical coordinates. The strength of this method is that it is easy to implement and does not require initial conditions.
The Skyrme–Hartree–Fock (SHF) method with MSK7 Skyrme parameter has been used to investigate the ground-state properties for two-neutron halo nuclei 6He, 11Li, 12Be and 14Be. These ground-state properties include the proton, neutron and matter density distributions, the corresponding rms radii, the binding energy per nucleon and the charge form factors. These calculations clearly reveal the long tail characterizing the halo nuclei as a distinctive feature.
This paper presents the effect of relativistic and ponderomotive nonlinearity on cross-focusing of two intense laser beams in a collisionless and unmagnetized plasma. It should be noted here that while considering the self-focusing due to relativistic electron mass variation, the electron ponderomotive density depression in the channel may also be important. Therefore/these two nonlinearties may simultaneously affect the self-focusing process. These nonlinearities depend not only on the intensity of one laser but also on the second laser. Therefore, one laser beam affects the dynamics of the second beam and hence the process of cross-focusing takes place. The electric field amplitude of the excited electron plasma wave (EPW) has been cal
... Show MoreSpent hydrodesulfurization (Co-Mo/γ-Al2O3) catalyst generally contains valuable metals like molybdenum (Mo), cobalt (Co), aluminium (Al) on a supporting material, such as γ-Al2O3. In the present study, a two stages alkali/acid leaching process was conducted to study leaching of cobalt, molybdenum and aluminium from Co-Mo/γ-Al2O3 catalyst. The acid leaching of spent catalyst, previously treated by alkali solution to remove molybdenum, yielded a solution rich in cobalt and aluminium.
This paper deals with, Bayesian estimation of the parameters of Gamma distribution under Generalized Weighted loss function, based on Gamma and Exponential priors for the shape and scale parameters, respectively. Moment, Maximum likelihood estimators and Lindley’s approximation have been used effectively in Bayesian estimation. Based on Monte Carlo simulation method, those estimators are compared in terms of the mean squared errors (MSE’s).
Bombay (Oh) and Para-Bombay are rare variants of the ABO blood group system that carry significant clinical importance. They are characterized by the absence or a marked reduction in the expression of the H antigen on red blood cells (RBCs). This deficiency leads to a failure in the synthesis of A and B antigens, predisposing patients—particularly those with the Bombay phenotype—to developing potent anti-H antibodies, which can cause severe hemolytic transfusion reactions. Objective: The primary goal is to provide clinicians and laboratory specialists with a practical and comprehensive framework to prevent avoidable blood mismatch and improve clinical outcomes for patients suffering from H-deficient phenotypes. Methods: This rev
... Show MoreA program in Visual Basic language was designed to predict the type of radio storm that emitted from Jupiter at specific Local Time (LT) from two different Iraqi locations (Baghdad and Basra), such storms result from the Central Meridian Longitude (CML) of system ??? for Jupiter and phase of Io’s satellite (?Io). Some of these storms are related to position of Io (Io- A,B,C,D) and others are unrelated (non-Io-A,B,C,D) to its position. The input parameters for this program were user specified by determining the observer’s location (longitude), year, month and day. The output program results in form of tables provides the observer with information about the date and the LT of beginning and end of each type of emitted storm. Two Io-storm r
... Show MoreBackground: This in vitro study evaluated the effect of canal dryness and flaring on the accuracy of two electronic apex locators for working length (WL) determination. Materials and methods: Sixty extracted teeth were used, after access opening was done, the occlusal surface was flattened to create stable reference point. The teeth were randomly divided into two equal main groups of flared and unflared group each one of 30 teeth. The flaring was done with Gates Glidden drills. The two main groups were further subdivided into two subgroups: dry canal and wet canal using 5.25% sodium hypochlorite groups, Electronic WL of each sample was determined using both Root ZX and i-Root apex locator. Consequently, histologic WL was determined by shav
... Show MoreThe aim of this paper is to describe an epidemic model when two SI-Type of diseases are transmitted vertically as well as horizontally through one population. The population contains two subclasses: susceptible and infectious, while the infectious are divided into three subgroups: Those infected by AIDS disease, HCV disease, and by both diseases. A nonlinear mathematical model for AIDS and HCV diseases is Suggested and analyzed. Both local and global stability for each feasible equilibrium point are determined theoretically by using the stability theory of differential equations, Routh-Hurwitz and Gershgorin theorem. Moreover, the numerical simulation was carried out on the model parameters in order to determine their impact on the disease
... Show MoreObjective: To evaluate the effect of mouth rinses (Biofresh and ZAK) on the surface micro hardness
of two light cure restorative material (Tetric ceram ivoclar-vivadent) and (3M Z 250) dental
composite.
Methodology: The microhardness values of (sixty) composite specimens were measured at the top
surfaces after 24 hours of immersion in different solutions (Biofresh, Zak mouth wash and distilled
water as control). Comparison done using descriptive statistics (mean, SD, SEM, minimum and
maximum values) and inferential statistics (ANOVA and LSD) test.
Results: The biofresh mouth rinse which has high alcohol containing has less effect on
microhardness of tetric ceram than the zak &distiled water , while the effect