Preferred Language
Articles
/
jnhm-144
HUNTING BEHAVIOR OF THE ORIENTAL HORNET, VESPA ORIENTALIS L., AND DEFENSE BEHAVIOR OF THE HONEY BEE, Apis mellifera L., IN IRAQ
...Show More Authors

When the guard honey bees, Apis mellifera L., form a clump at the hive entrance or on the flight board, the oriental hornet, Vespa orientails L., either creeps toward the clump or hovers over it in order to take a bee. Once the hornet creeps, only few bees facing the hornet become alert, rock their heads and antennae, open their wings, and take a posture of defense. The rest of the clump stays listless without any signal of concern. However, the clump stays dense and the defending bees do not detach themselves neither from the rest of the clump nor from each other. For this reason, it is very difficult for the hornet to grab a bee unless the latter makes a “mistake” by detaching herself from other adjacent bees. If the hornet grabs such a bee, the other defending bees will not attack the hornet to free that bee even when the latter is one centimeter from the others. The defending bees can capture the hornet only when the latter grabs one of them which stands very close to the others. The hornet seems very “aware” of such a situation; hence she seldom becomes a captive. On the other hand, hovering over the clump makes it easier for the hornet to grab a bee. The hovering puts all the clump, rather than part of it, on alert. If the hornet is persistent, which is not often the case, then the clump will no longer be dense. The bees will panicly disperse all over the flight board; hence the hornet can find a detached bee and grabs it easily. The hornet also waits on wing in front of the hive to capture an outgoing or incoming flying bee but the latter usually maneuver to escape. Also, foraging bees reduce their activity during main hours of hornet presence. Among the main factors reducing the hornet impact are the continuous chasing of hornets to each other and the non-persistent attempts of the hornets when they attack bee clumps.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering
Load-settlement Behavior of Steel Piles in Different Sandy Soil Configurations
...Show More Authors

In the case where a shallow foundation does not satisfy with design requirements alone, the addition of a pile may be suitable to improve the performance of the foundation design. The lack of in-situ data and the complexity of the issues caused by lagging in the research area of pile foundations are notable. In this study, different types of piles were used under the same geometric conditions to determine the load-settlement relationships with various sandy soil relative densities. The ultimate pile capacity for each selected pile is obtained from a modified California Bearing Ratio (CBR) machine to be suitable for axial pile loading. Based on the results, the values of Qu for close-ended square pile were increased by 15

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrochemical Behavior of Chemical Conversion Coated Aluminum ASA6061 in Chromic Acid
...Show More Authors

The corrosion behavior of bare and chemical conversion coated (through anodizing) aluminum ASA 606 I in stagnant chromic acid solutions . Solutions of 2, 6 & J O wt. % Cr03 at 45°C, have been investigated using polarization technique. The anodizing experiments were conducted under fixed conditions of 35 minute exposure time and 30 volt supplied voltage. The most important feature achieved was the great difference in behavior between the anodic polarization curves for bare and anodized aluminum in different concentrations of chromic acid solutions.

View Publication Preview PDF
Publication Date
Tue Sep 19 2017
Journal Name
Journal Of Engineering
Fire Flame Influence on the Behavior of reinforced Concrete Beams Affected by Repeated Load
...Show More Authors

The influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa).

To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the seco

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2017
Journal Name
International Journal Of Science And Research
Evaluating the Behavior of Ring Footing on Two-Layered Soil Subjected to Inclined Load
...Show More Authors

Evaluating the behavior of a ring foundation resting on multi-layered soil is one of the important issues facing civil engineers. Many researchers have studied the behavior of ring foundation rests on multi-layered soil with vertical loads acting on the foundation. In real life ring foundation can be subjected to both vertical and horizontal loads at the same time due to wind or the presence of soil. In this research, the behavior of ring footing subjected to inclined load has been studied using PLAXIS software. Furthermore, the effect of multi-layered soil has been simulated in the model. The results showed that both vertical and horizontal stresses are mainly affected when the inclination angle of the load exceeded 45 degrees with a reduc

... Show More
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Engineering
Fire Flame Influence on the Behavior of reinforced Concrete Beams Affected by Repeated Load
...Show More Authors

The influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa). To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the second method, sudden, water splash was use

... Show More
Publication Date
Tue Dec 26 2023
Journal Name
Proceedings Of Researchfora International Conference, Dubai, Uae
GREEN SYNTHESIS OF SILVER NANOPARTICLES FROM THE ALCOHOLIC EXTRACT OF LEAVES OF HELIANTHEMUM SALICIFOLIUM L
...Show More Authors

View Publication
Publication Date
Fri Nov 01 2019
Journal Name
Iop Conference Series: Earth And Environmental Science
The comparison of several methods for calculating the degree of heritability and calculating the number of genes in maize (Zea mays L.). I. Agronomic traits
...Show More Authors
Abstract<p>The objective of present study was to compare of several methods for estimating the degree of heritability and calculating the number of genes using generation mean analysis of maize (<italic>Zea mays</italic>L.). The experiment was conducted at the field of Field Crop Dept. College of Agric / Univ. of Baghdad, for many seasons, spring and fall seasons 2009, 2010, spring 2011 and fall 2013.Six diverse inbred lines were crossed to produce F1,F2,BC1 and BC2 for four superior crosses.Broad-sense and narrow sense heritability estimates based on variance of different generations. The results showed that the four formulas used to estimate the heritability were different in estimating the values o</p> ... Show More
View Publication
Scopus (4)
Scopus Crossref
Publication Date
Sun Dec 20 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Effect The behavior of workers in the insurance companies in achieving competitive advantage: An Applied research in a sample of the general insurance companies
...Show More Authors

Service companies always working to increase their competitiveness and efficiency of the survival, growth and development in the present and the future, including insurance companies, so as to increase competition, especially after the emergence of the civil companies dramatically after 2003, has become the goal of recent studies carried out by the organizations is the human capital, because its success and excellence and achievement its objectives depends on the human, and this does not mean that the other components are not important, but also rely on the rights which has increased interest in the search for the way in which they can guide the behaviors and values ​​and their own language in line with the organization's strategy an

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 30 2024
Journal Name
Iraqi Journal Of Science
The Impact of Fear and Anti-Predator Behavior on the Dynamics of Stage-Structure Prey–Predator Model With a Harvesting
...Show More Authors

In this paper, an ecological model with stage-structure in prey population, fear, anti-predator and harvesting are suggested. Lotka-Volterra and Holling type II functional responses have been assumed to describe the feeding processes . The local and global stability of steady points of this model are established. Finally, the global dynamics are studied numerically to investigate the influence of the parameters on the solutions of the system, especially the effect of fear and anti-predation.

Scopus (1)
Scopus Crossref
Publication Date
Sun Jan 27 2019
Journal Name
Civil Engineering Journal
Effect of Size and Location of Square Web Openings on the Entire Behavior of Reinforced Concrete Deep Beams
...Show More Authors

This paper presents an experimental and numerical study which was carried out to examine the influence of the size and the layout of the web openings on the load carrying capacity and the serviceability of reinforced concrete deep beams. Five full-scale simply supported reinforced concrete deep beams with two large web openings created in shear regions were tested up to failure. The shear span to overall depth ratio was (1.1). Square openings were located symmetrically relative to the midspan section either at the midpoint or at the interior boundaries of the shear span. Two different side dimensions for the square openings were considered, mainly, (200) mm and (230) mm. The strength results proved that the shear capacity of the dee

... Show More
View Publication
Crossref (12)
Crossref