Preferred Language
Articles
/
jmracpc-225
ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.: ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.
...Show More Authors

For aspirin estimated, a molecularly imprinted polymer MIP-ASP electrodes were generated by electro-polymerization process, the electrodes were prepared by combining the template (aspirin) with (vinyl acetate (VA), 1-vinylimidizole (VIZ) as a functional monomer and N, N-methylene bisacrylamide (MBAA) as crosslinkers using benzoyl peroxide (BPO) as an initiator. The efficiency of the membrane electrodes was analyzed by differential pulse voltammetry (DPV). Four electrodes were synthesized using two different plasticizers, di-butyl sebacate (DBS), di-octyl phthalate (DOP) in PVC matrix. Scanning electron microscopy (SEM) was used to describe the generated MIP, studying the electrodes properties, the slope, detection limit, and life time and linearity range. The effect of PH and interferes on the efficiency of the MIP electrode was investigated. The study has shown that the molecularly imprinted electrodes have high sensitivity and responsiveness to aspirin. The DPV value was linearly dependence on the aspirin concentration and a linear curve was obtained within the range of (1×10−1-5×10-4) M of aspirin with correlation coefficients are about (0.9974, 0.9966, 0.9938 and 0.9961) with slops value of (-21.41, -17.67, -17.47 and -18.67) and the detection limit for all electrodes ranging from (7.5×10-5-1×10-4) M. The molecularly imprinted electrode exhibited a good response with highly reproducible and no effect on interferes frequently available in pharmaceutical formulations. The approach employed is easy and fast. Also ASP membranes get a limited time of response, excellent mechanical stability, removable and are easy to construct.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Genetic Algorithm Optimization Model for Central Marches Restoration Flows with Different Water Quality Scenarios
...Show More Authors

A Genetic Algorithm optimization model is used in this study to find the optimum flow values of the Tigris river branches near Ammara city, which their water is to be used for central marshes restoration after mixing in Maissan River. These tributaries are Al-Areed, AlBittera and Al-Majar Al-Kabeer Rivers. The aim of this model is to enhance the water quality in Maissan River, hence provide acceptable water quality for marsh restoration. The model is applied for different water quality change scenarios ,i.e. , 10%,20% increase in EC,TDS and BOD. The model output are the optimum flow values for the three rivers while, the input data are monthly flows(1994-2011),monthly water requirements and water quality parameters (EC, TDS, BOD, DO and

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Comparative Study for the Proton Electronic Stopping Power of Some Polymers by Using Mathematica, SRIM2013, PSTAR, LibdEdx, and Experimental Databases
...Show More Authors

The available experimental data of proton electronic stopping power for Polyethylene, Mylar, Kapton and Polystyrene are compared with Mathematica, SRIM2013, PSTAR and libdEdx programs or databases.  The comparison involves sketching out both experimental and databases data for each polymer to discuss the agreement. Further, we use statistical means via standard deviation resulting from the mean normalized difference to describe the precise agreement among the databases and the experimental data. We found that there is not a specific one database can describe the experimental data for certain material at given proton energy.

View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
A New Approach for the Turbidimetric Determination of Hydronium ion by Using Homemade Linear Array Ayah 5SX1-T-1D-CFI Analyser
...Show More Authors

A new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
A comparison between the logistic regression model and Linear Discriminant analysis using Principal Component unemployment data for the province of Baghdad
...Show More Authors

     The objective of the study is to demonstrate the predictive ability is better between the logistic regression model and Linear Discriminant function using the original data first and then the Home vehicles to reduce the dimensions of the variables for data and socio-economic survey of the family to the province of Baghdad in 2012 and included a sample of 615 observation with 13 variable, 12 of them is an explanatory variable and the depended variable is number of workers and the unemployed.

     Was conducted to compare the two methods above and it became clear by comparing the  logistic regression model best of a Linear Discriminant  function written

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
A New Approach for the Turbidimetric Determination of Hydronium ion by Using Homemade Linear Array Ayah 5SX1-T-1D-CFI Analyser
...Show More Authors

A new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 02 2020
Journal Name
International Journal Of Pharmaceutical Research
A turbidimetric method for the quantitative determination of cyproheptadine hydrochloride in tablets using an optoelectronic detector based on the LEDs array
...Show More Authors

View Publication Preview PDF
Scopus (11)
Crossref (2)
Scopus Crossref
Publication Date
Sat Sep 28 2024
Journal Name
Asia-pacific Journal Of Molecular Biology And Biotechnology
A novel method for the degradation of human blood clot by immobilised bromelain using multi-walled carbon nanotube and polyphenol oxidase
...Show More Authors

Pathological blood clot in blood vessels, which often leads to cardiovascular diseases, are one of the most common causes of death in humans. Therefore, enzymatic therapy to degrade blood clots is vital. To achieve this goal, bromelain was immobilized and used for the biodegradation of blood clots. Bromelain was extracted from the pineapple fruit pulp (Ananas comosus) and purified by ion exchange chromatography after precipitation with ammonium sulphate (0-80 %), resulting in a yield of 70%, purification fold of 1.42, and a specific activity of 1175 U/mg. Bromelain was covalently immobilized on functionalized multi-walled carbon nanotubes (MWCNT), with an enzyme loading of 71.35%. The results of the characterization of free and immobilized

... Show More
View Publication
Crossref
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Detection of Cellular and Molecular Toxicity of Aloe vera Gel Crude Extract on the Roots of the Allium cepa
...Show More Authors

    The cellular and molecular toxicity effect  of Aloe Vera crude extract on meristem cells of onion  (Allium cepa)  roots were studied  . Different concentrations of this crude extract   20% ,10% ,5%   ,2% ( and 40%) were used at different periods ; 24 ,48 and 72 hour . Number of  chromosomal aberrations and the mitotic index was calculated . In addition, the genetic effects were observed by  using randomly amplified polymorphic DNA ( RAPD ) technique . The results  showed that the gel crud extract of Aloe vera  had inhibition effects on the growth of the onion roots with 10% EC50  value. Significant effects of this gel crud extract were also observed on the chromosomal a

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Study of the Change of the Total Solar Radiation Above Baghdad City for the Period from 1985.1989 By Using Satellite Antenna Data
...Show More Authors

 The solar radiation plays an important role on the energy balance of the earthatmosphere, which is the main source of energy.  Also the solar radiation is a main factor of all applications which use a solar energy as renewable energy source.  The purpose of this research is to study the monthly average changes for solar radiation for the period from 1985 to 1989 by using satellite Antenna Alignment from (NASA). The result shows that the monthly average radiation changes from one year to another because of the changing of it component of atmosphere, (gases, clouds and Aerosols) and as an enhancement for this conclusion, we compared the results with the monthly average radiation at clear atmosphere where the change was slig

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 07 2014
Journal Name
Baghdad Science Journal
Baysian and NonBaysian Methods to Estimate the two parameters of Logistic Distribution
...Show More Authors

In this paper ,the problem of point estimation for the two parameters of logistic distribution has been investigated using simulation technique. The rank sampling set estimator method which is one of the Non_Baysian procedure and Lindley approximation estimator method which is one of the Baysian method were used to estimate the parameters of logistic distribution. Comparing between these two mentioned methods by employing mean square error measure and mean absolute percentage error measure .At last simulation technique used to generate many number of samples sizes to compare between these methods.

View Publication Preview PDF
Crossref (1)
Crossref