Preferred Language
Articles
/
jmracpc-214
SYNTHESIS NEW LIQUID ELECTRODES FOR DETERMINATION DOMPERIDONE MALEATE BASED ON A MOLECULARLY IMPRINTED POLYMER: SYNTHESIS NEW LIQUID ELECTRODES FOR DETERMINATION DOMPERIDONE MALEATE BASED ON A MOLECULARLY IMPRINTED POLYMER
...Show More Authors

Liquid electrodes of domperidone maleate (DOMP) imprinted polymer were synthesis based on precipitation polymerization mechanism. The molecularly imprinted (MIP) and non-imprinted (NIP) polymers were synthesized using DOMP as a template. By methyl methacrylate (MMA) as monomer, N,Nmethylenebisacrylamide (NMAA) and ethylene glycol dimethacrylate (EGDMA) as cross-linkers and benzoyl peroxide (BP) as an initiator. The molecularly imprinted membranes were synthesis using acetophenone (APH), di-butyl sabacate (DBS), Di octylphthalate (DOPH) and triolyl phosphate (TP)as plasticizers in PVC matrix. The slopes and limit of detection of liquid electrodes obtained from the calibration curves ranged from (-18.88– -29.01) mV/decade and (4.0 × 10-5 – 6.0 × 10-5) M, respectively and the response time was about 60 seconds. The Liquid electrodes were filled with (10-2 M) standard solution of the drug and observed stable response for a pH ranged from 2.0 to 11.0 and with good selectivity for over several species. The fresh electrodes of synthesis were effectively used in the pharmaceutical sample to determine DOMP without any time consuming pretreatment measures.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Tracked Robot Control with Hand Gesture Based on MediaPipe
...Show More Authors

Hand gestures are currently considered one of the most accurate ways to communicate in many applications, such as sign language, controlling robots, the virtual world, smart homes, and the field of video games. Several techniques are used to detect and classify hand gestures, for instance using gloves that contain several sensors or depending on computer vision. In this work, computer vision is utilized instead of using gloves to control the robot's movement. That is because gloves need complicated electrical connections that limit user mobility, sensors may be costly to replace, and gloves can spread skin illnesses between users. Based on computer vision, the MediaPipe (MP) method is used. This method is a modern method that is discover

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (6)
Scopus Crossref
Publication Date
Sun Feb 25 2024
Journal Name
Baghdad Science Journal
Research on Emotion Classification Based on Multi-modal Fusion
...Show More Authors

Nowadays, people's expression on the Internet is no longer limited to text, especially with the rise of the short video boom, leading to the emergence of a large number of modal data such as text, pictures, audio, and video. Compared to single mode data ,the multi-modal data always contains massive information. The mining process of multi-modal information can help computers to better understand human emotional characteristics. However, because the multi-modal data show obvious dynamic time series features, it is necessary to solve the dynamic correlation problem within a single mode and between different modes in the same application scene during the fusion process. To solve this problem, in this paper, a feature extraction framework of

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Fri May 01 2020
Journal Name
Journal Of Physics: Conference Series
Determination the optimum orbit for low Earth satellites by changing the eccentricity
...Show More Authors
Abstract<p>The main objective of this paper is to determine an acceptable value of eccentricity for the satellites in a Low Earth Orbit LEO that are affected by drag perturbation only. The method of converting the orbital elements into state vectors was presented. Perturbed equation of motion was numerically integrated using 4<sup>th</sup> order Runge-Kutta’s method and the perturbation in orbital elements for different altitudes and eccentricities were tested and analysed during 84.23 days. The results indicated to the value of semi major axis and eccentricity at altitude 200 km and eccentricity 0.001are more stable. As well, at altitude 600 km and eccentricity 0.01, but at 800 km a</p> ... Show More
View Publication
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jul 05 2024
Journal Name
Journal Of Applied Spectroscopy
Spectrophotometric Method Using the Derivative for the Determination of the Drug Losartan
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Wed Jul 20 2022
Journal Name
International Journal Of Health Sciences
Determination the optimal conditions for production of nanocellulose from acetic acid bacteria
...Show More Authors

Bacteria could produce bacterial nanocellulose through a procedure steps: polymerization and crystallization, that occur in the cytoplasm of the bacteria, the residues of glucose polymerize to (β-1,4) lineal glucan chains that produced from bacterial cell extracellularly, these lineal glucan are converted to microfbrils, after that these microfbrils collected together to shape very pure three dimensional pored net. It could be obtained a pure cellulose that created by some M.O, from the one of the active producer organism like Acetic acid bacteria (AAB), that it is a gram -ve, motile and live in aerobic condition. The bacterial nanocellulose (BNC) have great consideration in many fields because of its flexible properties, features

... Show More
View Publication
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectroscopic Study for Determination of Amoxicillin Using Cobalt(II) as Complexing Metal
...Show More Authors

         This study includes analytical methods for the determination of the drug amoxicillin trihydrate (Amox.) in some pharmaceutical preparations using Cobalt ion (Co(II)) as complexing metal. The best conditions for complexation were: the reaction time was 20 minutes, pH=1.5 and the best temperature of reaction was 70 ËšC. Benzyl alcohol was the best solvent for extraction the complex.

Keywords: Amoxicillin, Cobalt(II), Complex, Molar ratio.

View Publication Preview PDF
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Emulsion Liquid Membrane for Pesticides Removal from Aqueous Solution: Emulsion Stability, Extraction Efficiency and Mass Transfer Studies
...Show More Authors

The current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % were

... Show More
Crossref (5)
Crossref
Publication Date
Tue Oct 24 2023
Journal Name
Environmental Engineering Research
Exploring electromembrane extraction and liquid membrane for efficient removal of heavy metals from aqueous solutions: An overview
...Show More Authors

Environmental pollution is experiencing an alarming surge within the global ecosystem, warranting urgent attention. Among the significant challenges that demand immediate resolution, effective treatment of industrial pollutants stands out prominently, which for decades has been the focus of most researchers for sustainable industrial development aiming to remove those pollutants and recover some of them. The liquid membrane (LM) method, specifically electromembrane extraction (EME), offers promise. EME deploys an electric field, reducing extraction time and energy use while staying eco-friendly. However, there's a crucial knowledge gap. Despite strides in understanding and applying EME, optimizing it for diverse industrial pollutant

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Emulsion Liquid Membrane for Pesticides Removal from Aqueous Solution: Emulsion Stability, Extraction Efficiency and Mass Transfer Studies
...Show More Authors

The current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % we

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed May 19 2010
Journal Name
Journal Of College Of Science, University Of Babylon
H-Point Standard Addition Method for Simultaneous Determination of Cimetidine and Erythromycin Ethylsuccinate Drugs Using Bromothymol Blue as a Chromogenic Complexing Agent
...Show More Authors

The H-Point Standard Addition Method (H-PSAM) has been applied for spectrophotometric simultaneous determination of Cimetidine and Erythromycin ethylsuccinate using Bromothymol Blue (BTB) as a chromogenic complexing agent in a buffer solution at pH 5.5.