Preferred Language
Articles
/
jmracpc-191
Determination of some heavy Metals in tattoo Stickers in Children sweets available in local markets: Determination of some heavy Metals in tattoo Stickers in Children sweets available in local markets
...Show More Authors

The objective of this study is to determination the content of some heavy metals (lead, cadmium, chromium) in colored tattoo stickers. twelve kinds of colored tattoo stikcers were collected from Baghdad markets, it was estimated heavy metals using atomic absorption spectrophotometer (Shimadzu A5000). The results indicated the concentrations of lead in all samples (1.61_1.00 mg / kg) and chromium in the three samples (0.85_0.97 mg / kg) while other samples are free of chromium , and cadmium. These elements are the components of printing inks and dyes in tattoo stickers, and this does not conform to the health and safety conditions for the packaging of food according to the organizations of the health and safety of the global food because the possibility of transmission of the components of these inks through the pores of the skin and transmitted directly to the bloodstream causing health damage possible to occur to humans as a result of the accumulation of these materials And elements in the body.    

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Utilizing Load and Loss Factors in Determination of the Technical Power Losses in Distribution System’s Feeders: Case Study
...Show More Authors

This study uses load factor and loss factor to determine the power losses of the electrical feeders. An approach is presented to calculate the power losses in the distribution system. The feeder’s technical data and daily operation recorded data are used to calculate and analyze power losses.

This paper presents more realistic method for calculating the power losses based on load and loss factors instead of the traditional methods of calculating the power losses that uses the RMS value of the load current which not consider the load varying with respect to the time. Eight 11kV feeders are taken as a case study for our work to calculate load factor, loss factor and power losses. Four of them (F40, F42, F43 and F

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Determination of Serum Adiponectin Levels in Normal Weight Women with Polycystic Ovary Syndrome
...Show More Authors

Background: Polycystic ovary syndrome (PCOS) is a common endocrine disorder in women of reproductive age with primary manifestations of infertility, menstrual dysfunction and clinical or biochemical hyperandrogenism (hirsutism, acne and elevated androgen). Adiponectin is the most abundant adipokine. It has insulin-sensitizing, anti-atherogenic, and antiinflammatory actions.Objective: Low adiponectin levels in women with PCOS have been largely attributed to obesity which is common among these patients. Therefore, the aim of this study was to measure adiponectin levels in normal weight women with PCOS and its contribution to development of disease.Subjects and Methods: Fifty two (52) women were included in this study with age ra

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Kinetic- spectrophotometric Method for the Determination of Naringenin in Pure and Supplements Formulations
...Show More Authors

          Simple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfac

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Tue Apr 01 2014
Journal Name
International Communications In Heat And Mass Transfer
Determination of a time-dependent thermal diffusivity and free boundary in heat conduction
...Show More Authors

View Publication
Scopus (18)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Wed Jan 26 2022
Journal Name
Iraqi Journal Of Science
Potentiometric Determination of Mebeverine Hydrochloride Using Imprinted Molecular Polymer in PVC Matrix Membrane‏
...Show More Authors

Publication Date
Mon Jan 01 2018
Journal Name
Ibn Al-haitham Jour.for Pure & Appl.sci.
Determination of Osteocalcin, Bone Alkaline Phosphatase, and Lysyl Oxidase in Iraqi Acromegalic Patients
...Show More Authors

This study was aimed to determine bone formation markers (OST and BALP) and lysyl oxidase in diabetes and non-diabetes Iraqi acromegaly patients in addition to find the relationship among these parameters. The present study conducted 60 acromegalic patients (30 diabetes & 30 non diabetes) attending National Diabetes Center / AL-Mustansiriya University/Baghdad, and 30 healthy individuals as a control group aged (35-60) years. All patients were administrated Sandostatin drug, and they were diagnosed by physician in the hospital.FBG, GH, IGF-1, OST, BALP, and LOX were determined in all groups. The results showed a highly significant rise in all parameters (GH, IGF-1, FBG, OST, BALP, and LOX values in serum of all patients when compared with n

... Show More
Publication Date
Sun Jun 03 2018
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Sulphite in Various Water Samples Via Chromium-1,5-Diphenylcarbazide Complex
...Show More Authors

A simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Dec 15 2018
Journal Name
Revista De Chimie
Determination of Ethanol in Fermented Broth by Headspace Gas Chromatography using Capillary Column
...Show More Authors

The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which

... Show More
Crossref (4)
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
A sensitive spectrophotometric determination of tadalafil in pharmaceutical preparations and industrial wastewater samples
...Show More Authors

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Feb 01 2010
Journal Name
Food Chemistry
Determination of aflatoxins in animal feeds by HPLC with multifunctional column clean-up
...Show More Authors

A reversed-phase HPLC method with fluorescence detection for the determination of the aflatoxins B1, B2, G1 and G2 in 42 animal feeds, comprising corn (16), soya bean meal (8), mixed meal (13), sunflower, wheat, canola, palm kernel, copra meals (1 each) was carried out. The samples were first extracted using acetonitrile:water (9:1), and was further cleaned-up using a multifunctional column. Optimum conditions for the extraction and chromatographic separation were investigated. By adopting an isocratic chromatographic system using a mobile phase comprising acetonitrile:methanol:water (8:27:65, v/v/v), the separation of the four aflatoxins was possible within 30 min. Recoveries for aflatoxins B1, B2, G1 and G2 were 98 ± 0.7%, 95 ± 1.0%, 94

... Show More
View Publication
Scopus (119)
Crossref (105)
Scopus Clarivate Crossref