|
Background: Double diabetes is the term used to describe situations in which a patient exhibits characteristics that are a combination of type 1 and type 2 Diabetes Mellitus. Metalloendopeptidase or Neprilysin is membrane-bound metallopeptidase. It has a wide range of physiological function and a variety of substrates. It has a significant impact on the proteolytic functions of the kidney, cardiovascular health, immunological response, cell proliferation, and fetal development. It also has a preventative effect on the onset of type 2 diabetes, obesity, and cancer. Objective: The study aims to assess the level of MEP in patients with double diabetes and determine its predictive value in the diagnosis of double diabetes. Subjects and Methods: Eighty participants were divided into two groups for this study. 40 patients with double diabetes made up the first group (G1), whereas 40 age- and gender-matched apparently healthy subjects made up the second group (G2), which served as the control group. ELISA was used to measure the serum's metalloendopeptidase level. For the measurement of HbA1c, whole blood was used. The measurement of insulin, blood glucose, and lipid profile were performed using serum. The HOMA test measured insulin resistance. Results: This study revealed a significant elevation in serum metalloendopeptidase levels in patients with DD (p value < 0.05). The ROC curves analysis for serum metalloendopeptidase level showed the area under the curve (AUC) of serum metalloendopeptidase (pg/mL) was 0.992. Conclusions: Serum metalloendopeptidase level could be used as a novel biomarker in patients with double diabetes. |
Communication between unmanned aerial vehicle (UAV) swarms and flying ad-hoc networks is critical and challenging since it is over open radio networks and energy, memory and processing budgets are severely constrained. Lightweight cryptography is the solution and ASCON — the NIST standard for lightweight authenticated encryption — has become a popular option for securing UAV links at a fraction of the energy cost of AES. The security of ASCON relies on one nonlinear device — 5-bit substitution box (S-box). However, this S-box is fixed and publicly known, and allows an adversary to precompute the cryptographic properties one time and then reuse them against all the protected traffic, and moreover, it does not meet the strict av
... Show More
Abstract: Narrow laser pulses have been essential sources in optical communication system. High data rate optical communication network system demands compressed laser source with unique optical property. In this work using pulsed duration (9) ns, peak power 1.2297mW, full width half maximum (FWHM) 286 pm, and wavelength center 1546.7 nm as compression laser source. Mach Zehnder interferometer (MZI) is built by considering two ways. First, polarization maintaining fiber (PMF) with 10 cm length is used to connect between laser source and fiber brag grating analysis (FBGA). Second, Nested Mach Zehnder interferometer (NMZI) was designed by using three PMFs with 10 cm length. These three Fibers are splicing to sing
... Show MoreRecently Tobit Quantile Regression(TQR) has emerged as an important tool in statistical analysis . in order to improve the parameter estimation in (TQR) we proposed Bayesian hierarchical model with double adaptive elastic net technique and Bayesian hierarchical model with adaptive ridge regression technique .
in double adaptive elastic net technique we assume different penalization parameters for penalization different regression coefficients in both parameters λ1and λ2 , also in adaptive ridge regression technique we assume different penalization parameters for penalization different regression coefficients i
... Show MoreThis paper presents a study of a syndrome coding scheme for different binary linear error correcting codes that refer to the code families such as BCH, BKLC, Golay, and Hamming. The study is implemented on Wyner’s wiretap channel model when the main channel is error-free and the eavesdropper channel is a binary symmetric channel with crossover error probability (0 < Pe ≤ 0.5) to show the security performance of error correcting codes while used in the single-staged syndrome coding scheme in terms of equivocation rate. Generally, these codes are not designed for secure information transmission, and they have low equivocation rates when they are used in the syndrome coding scheme. Therefore, to improve the transmiss
... Show MoreImage recognition is one of the most important applications of information processing, in this paper; a comparison between 3-level techniques based image recognition has been achieved, using discrete wavelet (DWT) and stationary wavelet transforms (SWT), stationary-stationary-stationary (sss), stationary-stationary-wavelet (ssw), stationary-wavelet-stationary (sws), stationary-wavelet-wavelet (sww), wavelet-stationary- stationary (wss), wavelet-stationary-wavelet (wsw), wavelet-wavelet-stationary (wws) and wavelet-wavelet-wavelet (www). A comparison between these techniques has been implemented. according to the peak signal to noise ratio (PSNR), root mean square error (RMSE), compression ratio (CR) and the coding noise e (n) of each third
... Show MoreAll the available reports on the issue of infertility confirmed the increase in this population problem worldwide. Although the accurate estimate of the number of infertile people is due to several reasons, including the discrepancy in the true definition of infertility (whether it extends for one, two or five years of failed pregnancy attempts), as well as the great discrepancy in the size of the selected population groups (large population sample size versus epidemiological studies) and defining the category that diagnosed included (individuals, women, or couples). The goal of today’s IVF program is to obtain high-quality embryos with high efficiency in development, which leads to an increase in live birth rates.
Abstract Objective: To assess nurses' beliefs toward reporting suspected child abuse. To achieve the objectives of the study a questionnaire of child abuse was used. Methodology:- The sample of the study consist of (224) registered nurses who were employed in general hospitals, pediatric hospitals, National psychiatry and mental illness center, nursing colleges, nursing schools. Data were collected from 20 April 2004 to 20 June 2004.Data were analyzed through the application of descriptive statistical analysis. Percentage frequency and mean and inferential data analysis ANOVA. Results: - The result of t
Background: Ejection fraction have been used frequently
for assessment of the left ventricular function, but can be
associated with errors in which myocardial performance
index have been used as another parameter to measure the
left ventricular function.
Objective: selecting another echocardiography parameter
for the assessment of myocardial in function instead of the
ejection fraction.
Methods: 160 patients referred to the echocardiogram unit
from the period december 2007 to august 2008 requesting
assessment of left ventricular function. After clinical
examination, routine blood tests; chest x-ray and
electrocardiographic recording have been completed. All
patients informed to come for this unit af
KE Sharquie, AA Noaimi, RA Flayih, Am J Clin Res Rev, 2020 - Cited by 4