Preferred Language
Articles
/
jkmc-94
The Immediate And Intermediate Results Of Percutaneous Balloon Aortic Valvuloplasty In Patients With Congenital Valvular Aortic Stenosis
...Show More Authors

Background: Aortic valve stenosis results from minor to severe degrees of aortic valve maldevelopment. This stenosis causes mild to severe obstruction of the left ventricular outflow .

Objectives : to study the immediate and intermediate results of percutaneous balloon aortic valvuloplasty in patients with congenital valvular aortic stenosis .

Type of the study: A prospective study.

Methods: The study was done on thirty five patients with congenital valvular aortic stenosis who had percutaneous balloon aortic valvuloplasty  in Ibn Al- Bitar Center for Cardiac Surgery from May 2009 to February 2011.

Results: Twenty seven patients were male (77.2%) and 8 patients were female (22.8%), male to female ratio 3.5/ 1, . The aortic valve was bicuspid in 18 patients (51.4%) while 17 patients ( 48.6%) had tricuspid aortic valve. Balloon aortic valvuloplasty was successful in 30 patients (85.7%),. Maximum peak instantaneous Doppler pressure gradient across the aortic valve 24 hours postprocedural echocardiography showed reduction which is statistically significant. New aortic regurgitation had occurred in 15 patients ( 42.8%), it was mild in 9 patients ( 25.6%), moderate in 5 patients ( 14.3%) and severe in 1 patient( 2.9%) which is statistically significant. The follow up of 12.57 ± 3.88 ( 3- 22) months after intervention was done for all patients using echocardiography Doppler study, reveal the maximum peak instantaneous Doppler pressure gradient  across the aortic valve was raised  which is statistically significant. The aortic regurgitation was present in 18 patients (51.4%) , it was mild in 9 patients (25.7%) , moderate in 6 patients (17.1%) and severe in 3 patients  ( 8.6%). No mortality had been reported during the procedure or on follow up.

                                                                                 Conclusion: Aortic balloon valvuloplasty is safe and effective procedure in the treatment of congenital valvular aortic stenosis but mild aortic regurgitation is the most common immediate complication of aortic balloon dilatation and progressive aortic regurgitation is a major problem during the intermediate follow up.

                                                                                                                                              

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 16 2017
Journal Name
Journal Of Health, Medicine And Nursing
Prevalence of Congenital Heart Disease in Infants of Diabetic Mothers in Children Welfare Teaching Hospital
...Show More Authors

Women with diabetes in pregnancy (type 1, type 2 and gestational) are at increased risk for adverse pregnancy outcomes which also include infant development of congenital heart disease and even fetal death. Adequate glycemic control before and during pregnancy is crucial to improve outcome

Publication Date
Wed Sep 13 2023
Journal Name
Aip Conference Proceedings
Results for the (b,t)-blocking sets in PG(2,8)
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Journal Of Educational And Psychological Researches
Teachers and Headmasters’ Perspectives toward the Application of the Organizational Culture in the Intermediate and Secondary Schools in Arar city
...Show More Authors

The aim of the current research is to identify the level of organizational culture among the headmasters and teachers of intermediate and secondary schools in Arar city. It also aims to identify the effect of job variables, qualifications, educational stage, and years of experience on the level of organizational culture and its domains. The research sample consisted of 62 participants divided into 7 headmasters and 55 teachers. The researcher used the questionnaire of the organizational culture. The researcher used also statistical methods such as mean, standard deviation, t-test, and One way ANOVA. The results revealed that the level of organizational culture and its four domains were high, and there was no effect of the variables (teac

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 02 2021
Journal Name
مجلة بحوث الشرق الأوسط
Iraqi women's participation in athletics in the Arab Games from 1948 to 2017 and the results achieved.
...Show More Authors

This study dealt with the presentation and documentation of the Iraqi women's participations in athletics in the Arab sports courses since the establishment of the Federation of Athletics in 1948 to 2017 as well as analysis of the results achieved for these participations and discuss the reasons for not participating in some of these courses and the researchers try to show the distinct role of Iraqi athletes, And their active contribution to these courses to represent the country as well as to promote the sports reality of Iraqi women compared to their Arab sisters, whose names have become a symbol of every Arab woman and therefore benefit from the experience of the Arab teams In athletics for women.

View Publication Preview PDF
Crossref
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Bilayer Tablets Containing Immediate Release Aspirin Layer and Floating Clopidogrel Layer
...Show More Authors

Aspirin and clopidogrel are considered the most important oral platelets aggregation inhibitors. So it is widely used for treatment and prophylaxis of cardiovascular and peripheral vascular diseases related to platelets aggregation .In this study aspirin and clopidogrel were formulated together as floating bilayer tablet system. Three different formulas of 75 mg aspirin were prepared by wet granulation method as immediate release layer; different disintegrants used to achieve rapid disintegration. Formula with crosscarmellose as disintegrant achieve rapid disintegration was selected for preparation of bilayer tablet.

Different formulas of 75 mg clopidogrel were prepared as sustained release floating layer by wet granulation (effe

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Al-kindy College Medical Journal
Abdominal Distention and Acute Urinary Retention secondary to Congenital Distal Vaginal Obstruction in a Newborn Female
...Show More Authors

Congenital distal vaginal obstruction is usually asymptomatic in a newborn female. On rare occasions, it may present as an acute emergency with life threatening complications.This paper is reporting the rare condition of two newborn females presenting urgently with abdominal distension and acute urinary retention as a result of congenital distal vaginal Obstruction. The case history and urgent management shall be presented and both conditions shall be discussed.

View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Imdc-sdsp
Emotion management among the headmaster of intermediate schools
...Show More Authors

Publication Date
Tue Oct 04 2022
Journal Name
Azerbaijan Medical Journal
Ultrasonic fetal Doppler and growth indices and their relation to immediate neonatal outcomes in different severities of maternal anemia
...Show More Authors

Doppler assessment may lead to intervention that reduces the risk of fetal brain damage. Aim of thestudy: to assess the relation between ultrasonic hemodynamic Doppler indices of middle cerebral and umbilical arteries (PI, RI), growth indices to immediate neonatal outcomes (weight, head & abdominal circumference, APGAR scores at 1 and 5 minutes and neonatal unit admission) in women with mild, moderate and severe anemia during pregnancy. Present study is a clinical prospective study carried out in Al-Elwiya Maternity Teaching Hospital during (January-Jun) 2019, all anemic pregnant women presented to Obstetrical wards in hospitals for emergency cesarean section were the study population. The final sample selected was 120 pregnant women. Ultra

... Show More
Publication Date
Thu May 09 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Formulation and Evaluation of Immediate-Release Oral Tablets Containing Magnesium Aluminum Silicate-Loaded Simvastatin
...Show More Authors

Background: Simvastatin (SIM) is a lipid-lowering agent to prevent disorders caused by clogged blood vessels. Because of its low solubility, it has low bioavailability. The adsorption technique is effective in improving drug solubility and dissolution rate. Objective: To use magnesium aluminum silicate (MAS) as an adsorbent in combination with Soluplus® as a hydrophilic polymer to formulate SIM as immediate-release tablets (IRTs). Methods: We used the solvent evaporation method to make MAS-loaded SIM in the presence of Soluplus®, making sure that the ratio of SIM to MAS to SOLU was 1:6:3. We then used this mixture to make IRTs. Using the direct compression method, we made all of the SIM-IRT formulas. We used diluents like Avicel

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
Some Results on the Average Inverse Shadowing Property and Strong Ergodicity
...Show More Authors

View Publication Preview PDF
Scopus Clarivate Crossref