Preferred Language
Articles
/
jkmc-94
The Immediate And Intermediate Results Of Percutaneous Balloon Aortic Valvuloplasty In Patients With Congenital Valvular Aortic Stenosis
...Show More Authors

Background: Aortic valve stenosis results from minor to severe degrees of aortic valve maldevelopment. This stenosis causes mild to severe obstruction of the left ventricular outflow .

Objectives : to study the immediate and intermediate results of percutaneous balloon aortic valvuloplasty in patients with congenital valvular aortic stenosis .

Type of the study: A prospective study.

Methods: The study was done on thirty five patients with congenital valvular aortic stenosis who had percutaneous balloon aortic valvuloplasty  in Ibn Al- Bitar Center for Cardiac Surgery from May 2009 to February 2011.

Results: Twenty seven patients were male (77.2%) and 8 patients were female (22.8%), male to female ratio 3.5/ 1, . The aortic valve was bicuspid in 18 patients (51.4%) while 17 patients ( 48.6%) had tricuspid aortic valve. Balloon aortic valvuloplasty was successful in 30 patients (85.7%),. Maximum peak instantaneous Doppler pressure gradient across the aortic valve 24 hours postprocedural echocardiography showed reduction which is statistically significant. New aortic regurgitation had occurred in 15 patients ( 42.8%), it was mild in 9 patients ( 25.6%), moderate in 5 patients ( 14.3%) and severe in 1 patient( 2.9%) which is statistically significant. The follow up of 12.57 ± 3.88 ( 3- 22) months after intervention was done for all patients using echocardiography Doppler study, reveal the maximum peak instantaneous Doppler pressure gradient  across the aortic valve was raised  which is statistically significant. The aortic regurgitation was present in 18 patients (51.4%) , it was mild in 9 patients (25.7%) , moderate in 6 patients (17.1%) and severe in 3 patients  ( 8.6%). No mortality had been reported during the procedure or on follow up.

                                                                                 Conclusion: Aortic balloon valvuloplasty is safe and effective procedure in the treatment of congenital valvular aortic stenosis but mild aortic regurgitation is the most common immediate complication of aortic balloon dilatation and progressive aortic regurgitation is a major problem during the intermediate follow up.

                                                                                                                                              

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Apr 15 2023
Journal Name
History Of Medicine
Assessment of Alpha-Fetoprotein in Cerebrospinal Fluid, Plasma and Its Correlation to Some Biochemical Parameters in New Born with Congenital Hydrocephalus
...Show More Authors

ATAW Eqbal Abdul Ameer'. Shifaa Jameel Ibrahim?, HISTORY Of MEDICINE, 2023

View Publication
Publication Date
Sat Aug 01 2015
Journal Name
2015 37th Annual International Conference Of The Ieee Engineering In Medicine And Biology Society (embc)
Wave speed and reflections proximal to aneurism and stenosis of flexible tubes
...Show More Authors

Arterial aneurism and stenosis are disorders that lead to circulation malfunction. Stenosis often leads to hypoxia of the organ depending on the affected artery, whilst aneurism can lead to dissection with known lethal consequences. On both cases, the pulse wave produced by the contracting heart is reflected at these discontinuities, and estimating the size of these reflected waves using wave intensity analysis (WIA) is the main aim of this work. We also aim to measure wave speed, or pulse wave velocity (PWV) as more commonly known within the discontinuities. We manufactured 4 stenosis and 4 aneurism silicon sections, connected one at a time to a mother tube, and tested in vitro. Pressure and flow were measured proximal to the discontinuity

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Mar 01 2017
Journal Name
Journal Of Craniofacial Surgery
Lateral Ridge Splitting (Expansion) With Immediate Placement of Endosseous Dental Implant Using Piezoelectric Device
...Show More Authors

View Publication
Crossref (16)
Crossref
Publication Date
Mon Jul 28 2025
Journal Name
Modern Sport
Precision tracking and visual animation and its relationship to the results of the competition with the Sabre Players.
...Show More Authors

In order to get advanced results, we must stand at the pointsthat have been observed by the trainers that are of significance inthe sport of fencing and concern for capacity optical (traceoptical and precision visual animation), so we must learn some ofthese types of capacity, whichever is more influential in the gamefencing so that they add a new axis to the player to pick andchoose in order to achieve the desired goal and raise the level ofthe game.The study aimed to identify the relationship between the visualtracking and accuracy of visual animated face and the results ofcompetitions Sabre of the other.Used a much more descriptive approach to study relational on asample of players clubs Sabre and the way intentional, whoqualified to the

... Show More
View Publication
Publication Date
Sun Sep 27 2020
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of Educational Program on Nurses Knowledge toward Nursing Management for Patients Undergoing Percutaneous Coronary Intervention in Cardiac Center at Al-Dewaniyah City
...Show More Authors

Objectives: The study aims to evaluate the effectiveness of the educational program on nurses’ knowledge towards nursing management for patients undergoing percutaneous coronary intervention (PCI), as well as to find out the relationship between nurses' knowledge and some of their demographic characteristics (age, gender, level of education, and years of experience in cardiac units).

Methodology:  A Quasi-experimental as one group (pre and post test) study was conducted at the Heart Center in Al-Diwaniyah city for the period from December 7, 2019 to February 23, 2020. A sample of (40) nurses working in the heart center was chosen from different nursing addresses. The sample covered one gro

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Pakistan Journal Of Life And Social Sciences (pjlss)
Effect of Aromatherapy on Pain Intensity for Patients Undergoing Arterial Sheath Removal after Percutaneous Coronary Intervention: A Randomized Controlled Trial
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Engineering
THE EFFECTS OF BLOOD REHEOLOGICAL ON THE FLOW THROUGH AN AXISYMMETRIC ARTERIAL STENOSIS
...Show More Authors

The prediction of the blood flow through an axisymmetric arterial stenosis is one of the most important aspects to be considered during the Atherosclrosis. Since the blood is specified as a non-Newtonian flow, therefore the effect of fluid types and effect of rheological properties of non-Newtonian fluid on the degree of stenosis have been studied. The motion equations are written in vorticity-stream function formulation and solved numerically. A comparison is made between a Newtonian and non-Newtonian fluid for blood flow at different velocities, viscosity and Reynolds number were solved also. It is found that the properties of blood must be at a certain range to preventing atheroscirasis

View Publication Preview PDF
Crossref
Publication Date
Tue Apr 01 2025
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Congenital Anomalies in Neonates: Findings from Six Baghdad Hospitals
...Show More Authors

Background: Birth defects are the leading cause of both neonatal and post-neonatal deaths, as an estimated 240,000 neonates die in their first month of life worldwide each year. In Iraq, local studies have shown varying frequencies and types of congenital anomalies. Objectives: To provide new insight into the incidence and types of congenital anomalies and to explore their possible risk factors in Baghdad City. Methods: In this cross-sectional observational study, a total of 2007 neonates were enrolled from six hospitals in Baghdad during the period extending between September and December 2020. Hospital records and personal interviews were used for data collection. These data included the neonates' demographic and clinical characte

... Show More
View Publication
Crossref
Publication Date
Tue Jan 10 2012
Journal Name
Iraqi Journal Of Community Medicine
Evaluation of physical parameters in mitral valve stenosis by using Doppler Ultrasound
...Show More Authors

Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages rang

... Show More
Publication Date
Wed Jan 30 2013
Journal Name
Al-kindy College Medical Journal
MODIFICATION OF TUBULARIZED INCISED PLATE URETHROPLASTY IN HYPOSPADIUS REPAIR FOR PREVENTING FISTULA AND MEATAL STENOSIS.
...Show More Authors

Objective: to evaluate the benefit of coverage of
the urethral repair by dorsal dartos flap as a second
layer for preventing fistula and V like incision on
the tip of the glans for preventing meatal stenosis.
Patients and Methods:
Forty five children included in this study age
ranged ( 11 months – 7 years), they underwent
hypospadias repair between December 2008 to
March 2012, all cases with distal hypospadias,
same technique used for all patients, a combination
of techniques used for reconstruction starting
withtubularized incised plate urethroplasty with deepithelialized
or stripping of the skin from both
sides of U shaped incision surrounding the urethral
plate, adding a V like incision on t

... Show More
View Publication Preview PDF