Preferred Language
Articles
/
jkmc-934
Salivary Interleukin-6 Level in Iraqi Patients with Oral Lichen Planus receiving Platelet-Rich Plasma Injections
...Show More Authors

Background: Interleukin-6 (IL-6) is a cytokine that has several functions, including stimulating growth and inhibiting cell death. It has the potential to operate as a biomarker for the accurate prediction of disease severity and activity, platelets-rich plasma was used in the treatment of oral lichen planus and can change the salivary IL-6 level.

Objectives: To study the clinical outcome of intralesional platelets-rich plasma in patients with oral lichen planus and to measure salivary IL-6 levels before and after the treatment with platelets-rich plasma were the aims of this study.

Subjects and Methods: In this clinical trial, for each patient a standardized case sheet was filled including demography, social, medical, and medication history. Before receiving, each patient was examined for phenotype, color, size, and site of oral lichen planus lesions. Patient's salivary samples were taken between 8 and 11 a.m. Three to four milliliters of saliva was obtained from each patient. The ELISA kit for IL-6 using sandwich-ELISA technique, to measure salivary IL-6 before and after PRP injections.

Results: Thirteen oral lichen planus patients were took part in this study, six males (46.2%) and seven females (53.8%). The patients were between 32 and 91 years of age, with a mean age of 60.2(±13.9) years. All symptomatic and most of the hyperemic ones showed improvement after PRP injections, while the size of the lesions was resistant to change. Mean salivary IL-6 was 44.27 pg/mL (±43.24) before PRP injections and (69.74±59.86 pg/mL) after PRP injections. No significant difference was found, however IL-6 was higher after PRP injections. In relation to color changes after PRP, there was a significant changes in IL-6 level compared with that before PRP injections. Similarly, a significant relation was found between IL-6 level and signs and symptoms; pain and burning sensation. No association was found in salivary IL-6 level in relation to lesion phenotype, size, and location.

Conclusion: All symptomatic OLP lesions that were treated with intralesional PRP responded very well, similarly almost all hyperemic lesions turned into normal mucosal color after completing the course of treatment. The majority of OLP lesions showed an increased salivary IL-6 levels after PRP treatment. 

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Study of the Immunological Status of Iraqi Vitiligo Patients
...Show More Authors

Vitiligo is an acquired idiopathic skin disorder characterized by depigmented macules due to loss of cutaneous melanocytes. A potential role of the immune dysfunction has been suggested in vitiligo, so to test this hypothesis, certain cytokines (IL-17A and TNF-?) and immunoglobulins (IgM, IgG, IgA and total IgE) were investigated in all participants. The study included: 60 patients with age range between (6-55) year; 30(11 males and 19 females) were untreated and 30(12 males and 18 females) were treated with Narrow Band Ultraviolet-B (NB-UVB) and 30 (14 males and 16 females) apparently healthy control. Serum was separated and cytokines (IL-17A and TNF-?) and total immunoglobulin E (IgE) were detected by using Enzyme Linked Immunosorbent Ass

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Mar 03 2022
Journal Name
Trends In Sciences
Computational Study of Charge Density Produced in N2: H2 Plasma Actuator
...Show More Authors

Numerical simulation of charge density produced in plasma actuators is dependent upon the development of models dealing with electrical properties. The main aim of this work is to investigate the characteristics surface charge density and space charge density of DBD plasma actuator. A simple design of surface dielectric barrier discharge plasma actuator is used in the study. The discharge gas was N2:H2 mixture with applied voltage equal to 1.5 kV. A theoretical plasma model is used to establish the charge density details. Results show that surface charge density increased in value and spread in width alone the exposed electrode as the voltage increased and reached to the amplitude value.

Preview PDF
Publication Date
Sun Apr 02 2017
Journal Name
Research Journal Of Pharmaceutical, Biological And Chemical Sciences
GLP-1, GPCR Levels and their Relationshipwith Some Parameters in Nondiabetic Dyslipidaemia in Iraqi Patients
...Show More Authors

Abnormalities in the Lipid and lipoprotein levels are common in the general population and are considered as very important risk- factors for cardiovascular disease .In this context the effect of cholesterol, which is one of the most clinically relevant lipids is very important. Aim of the present study was to determine the levels of GLP-1 and GPCR in non- diabetic dyslipidaemic patients and compare the results with the control group, which may be used as a novel biomarker to predict heart disease in these patients. The study was also aimed to find the relationship between GLP-1 and GPCR with lipid profile and glucagon in the patient group. The study involved 90 non-diabetic dyslipidaemia patients, with 90 healthy controls. The subjects wer

... Show More
Publication Date
Mon Sep 01 2025
Journal Name
Journal Of Cancer Research Updates
Hematological Parameters in Liver Metastasis: A Comprehensive Clinical Evaluation for Early Detection in Iraqi Patients
...Show More Authors

Background: Liver metastasis significantly complicates cancer prognosis, yet easily accessible markers for its early detection and monitoring remain crucial. This study aimed to comprehensively evaluate key hematological parameters as potential indicators for liver metastasis in Iraqi patients. Methods: We conducted a cross-sectional study comparing hematological profiles between 90 patients (presumably with liver metastasis) and 30 healthy controls. White Blood Cell (WBC) count, Lymphocyte percentage, Neutrophil percentage, and Neutrophil-to-Lymphocyte Ratio (NLR) were analyzed. Given non-normal data distributions (confirmed by the Shapiro-Wilk test), group comparisons were performed using the non-parametric Mann-Whitney U test.

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The role of TNF-? in the pathogenesis of multiple myeloma “a study in Iraqi patients”
...Show More Authors

During recent years, there has been an increasing interest in the investigation of the cytokines roles in pathogenesis of cancer, thus the study aimed at evaluating the level of tumor necrosis factor-alpha(TNF-?) in sera of Iraqi multiple myeloma (MM) patients. Beta 2-microglobulion (?2-m) was assessed to determine if there was any association between this cytokine and the level of ?2- m, as the latter is related to the stage of the disease. In addition, the age and gender were also taken into consideration. Furthermore, we investigated the relationship between IgG and TNF-? in sera of patients. 49 Iraqi patients (27 males and 22 females).The patients were also divided into two groups: the first group included (17) patients who were

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Cureus
The Evaluation of Dihydropyrimidine Dehydrogenase Enzyme Level in the Serum of Colorectal Cancer Iraqi Males on Fluoropyrimidine-Based Chemotherapy (Capecitabine)
...Show More Authors

View Publication Preview PDF
Crossref (1)
Clarivate Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Electrical, thermal and optical characteristics of plasma torch
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was constructed. The experimental set up was based on simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases which flow at atmospheric pressure. A high AC power supply was used with 9.6kV peak to peak and 33kHz frequency. The plasma was generated using two electrodes. The voltage and current discharge waveform were measured. The temperature of Ar gas plasma jet at different gas flow rate and distances from the plasma electrode was also recorded. It was found that the temperature increased with increasing frequency to reach the maximum value at 15 kHz, and that the current leading the voltage, which demonstra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Thermophysical properties of [EMIM][BF<sub>4</sub>] and [HMIM][PF<sub>6</sub>] imidazolium ionic liquids with MWCNTs
...Show More Authors
Abstract<p>In this study, several ionanofluids (INFs) were prepared in order to study their efficiency as a cooling medium at 25 °C. The two-step technique is used to prepare ionanofluid (INF) by dispersing multi-walled carbon nanotubes (MWCNTs) in two concentrations 0.5 and 1 wt% in ionic liquid (IL). Two types of ionic liquids (ILs) were used: hydrophilic represented by 1-ethyl-3-methylimidazolium tetrafluoroborate [EMIM][BF<sub>4</sub>] and hydrophobic represented by 1-hexyl-3-methylimidazolium hexafluorophosphate [HMIM][PF<sub>6</sub>]. The thermophysical properties of the prepared INFs including thermal conductivity (TC), density and viscosity were measured experimental</p> ... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Synthesis and characterization of new phthalimide with 6- mercaptopurine or 2- aminothiazole conjugate used dithiocarbamate spacer as anticancer agents
...Show More Authors

View Publication
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Minar International Journal Of Applied Sciences And Technology
Electron density spectroscopic measurement in Al laser induced plasma
...Show More Authors

Plasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibri

... Show More