Preferred Language
Articles
/
jkmc-898
Persistent Intraocular Pressure Elevation after Silicon Oil Removal in Patients with Post-Pars Plana Vitrectomy: IOP Level After SO Removal
...Show More Authors

Background: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure.

Objectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD)

Subjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO removal. Follow-up was performed at 1, 4, and 8 weeks after SO removal. IOP was measured by Goldman applanation tonometer. Patients with IOP > 21 mm Hg at 8 weeks post-operatively with or without anti-glaucoma mediations were considered as persistent IOP elevation after SO removal.

Result: Sixty eyes of 60 patients were included. Twenty eyes had persistent IOP elevation after SO removal on first week postoperative. It decreased to 14 eyes on 4th week after SO removal and further decreased to 12 eyes on 8th week af-ter SO removal. The percentage of persistent IOP elevation following SO remov-al was about 20%  on 8th week of SO removal. 

Conclusion: Persistent IOP elevation sometimes happens after SO removal. Therefore, removing SO does not simply treat the elevated IOP happened during SO injection. Patients after SO removal should be followed up for IOP for several weeks and should be treated medically or surgically as required.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 15 2015
Journal Name
Journal Of Physical Vapor Deposition Science And Technology (jpvdst)
Physical Properties of Nanostructured Silicon Dioxide Prepared by Pulsed-Laser Deposition
...Show More Authors

Publication Date
Mon Jan 01 2024
Journal Name
Baghdad Science Journal
Bi-Distance Approach to Determine the Topological Invariants of Silicon Carbide
...Show More Authors

          The use of silicon carbide is increasing significantly in the fields of research and technology. Topological indices enable data gathering on algebraic graphs and provide a mathematical framework for analyzing the chemical structural characteristics. In this paper, well-known degree-based topological indices are used to analyze the chemical structures of silicon carbides. To evaluate the features of various chemical or non-chemical networks, a variety of topological indices are defined. In this paper, a new concept related to the degree of the graph called "bi-distance" is introduced, which is used to calculate all the additive as well as multiplicative degree-based indices for the isomer of silicon carbide, Si2

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Iraqi Journal Of Agricultural Sciences
Effect of silicon, calcium and boron on apple leaf minerals content
...Show More Authors

Scopus (14)
Scopus
Publication Date
Wed Feb 01 2012
Journal Name
International Review Of Physics (e-journal) (irephy)
Some structural properties studying of porous silicon preparing by photochemical etching
...Show More Authors

Preview PDF
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
Characterization Performance of Monocrystalline Silicon Photovoltaic Module Using Experimentally Measured Data
...Show More Authors

Solar photovoltaic (PV) system has emerged as one of the most promising technology to generate clean energy. In this work, the performance of monocrystalline silicon photovoltaic module is studied through observing the effect of necessary parameters: solar irradiation and ambient temperature. The single diode model with series resistors is selected to find the characterization of current-voltage (I-V) and power-voltage (P-V) curves by determining the values of five parameters ( ). This model shows a high accuracy in modeling the solar PV module under various weather conditions. The modeling is simulated via using MATLAB/Simulink software. The performance of the selected solar PV module is tested experimentally for differ

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Ethanol-Water Separation by Pressure Swing Adsorption (PSA)
...Show More Authors

Single long spiral tube column pressure swing adsorption (PSA) unit, 25 mm diameter, and 6 m length was constructed to study the separation of water from ethanol at azeotropic concentration of 95 wt%. The first three meters of the column length acted as a vaporizer and the remaining length acted as an adsorber filled by commercial 3A zeolite. The effect of pressure, temperature and feed flow rate on the product ethanol purity, process recovery and productivity were studied. The results showed that ethanol purity increased with temperature and pressure and decreased with feed flow rate. The purity decreased with increasing productivity. The purity range was 98.9 % to 99.6 %, the recovery range was 0.82 to 0.92 and the productivity range w

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Estimation of Bladder pressure by using poiseuilles equation
...Show More Authors

Equation Boizil used to Oatae approximate value of bladder pressure for 25 healthy people compared with Amqas the Alrotinahh ways used an indirect the catheter Bashaddam and found this method is cheap and harmless and easy

View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
All Days
Optimum Separation Pressure for Heavy Oils Sequential Separation
...Show More Authors
Abstract<p>The estimation of quantity of liquid that is collected from gas/oil separation system is a very complex task because it requires the application of the flash calculations which needs to solve the cubic equation of state and to use some numerical techniques. These difficulties can be overcome by a computer model which requires a lot of experimental data, long time, and experience.</p><p>This paper adopts a new technique to simplify this problem. It suggests new correlations for optimum separator pressure for separation station of heavy oils. The correlations have been achieved for two- and three- stage separation systems.</p><p>The co</p> ... Show More
View Publication
Scopus (3)
Crossref (4)
Scopus Crossref
Publication Date
Mon Nov 17 2025
Journal Name
Al-nahrain Journal For Engineering Sciences
Optimum Height of Plate Stiffener under Pressure Effect
...Show More Authors

The economical design of plate loaded by pressure can be obtained by using stiffeners instead of increasing the thickness of plate. The main subject of this work is to obtain the effect of stiffener height on the maximum stress in the plate subjected to pressure load. Different plate-stiffener sets are selected to find the effects of stiffener thickness, plate dimensions and pressure, on the optimum stiffener height. The models under consideration are square plates clamped rigidly from four edges. Finite Element method is used to analyze 160 different models by using the Finite Element software package ANSYS version 11. Another analysis method based on maximum stress equation is used to analyze 30 models. The graphical comparison of results

... Show More
View Publication
Publication Date
Wed Jun 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Producing Oil from Dead Oil Wells Using injected LPG
...Show More Authors

In order to reduce hydrostatic pressure in oil wells and produce oil from dead oil wells, laboratory rig was constructed, by injecting LPG through pipe containing mixture of two to one part of East Baghdad crude oil and water. The used pressure of injection was 2.0 bar, which results the hydrostatic pressure reduction around 246 to 222 mbar and flow rate of 34.5 liter/hr fluid (oil-water), at 220 cm injection depth. Effects of other operating parameters were also studied on the behavior of two phase flow and on the production of oil from dead oil wells.

View Publication Preview PDF