Preferred Language
Articles
/
jkmc-898
Persistent Intraocular Pressure Elevation after Silicon Oil Removal in Patients with Post-Pars Plana Vitrectomy: IOP Level After SO Removal
...Show More Authors

Background: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure.

Objectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD)

Subjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO removal. Follow-up was performed at 1, 4, and 8 weeks after SO removal. IOP was measured by Goldman applanation tonometer. Patients with IOP > 21 mm Hg at 8 weeks post-operatively with or without anti-glaucoma mediations were considered as persistent IOP elevation after SO removal.

Result: Sixty eyes of 60 patients were included. Twenty eyes had persistent IOP elevation after SO removal on first week postoperative. It decreased to 14 eyes on 4th week after SO removal and further decreased to 12 eyes on 8th week af-ter SO removal. The percentage of persistent IOP elevation following SO remov-al was about 20%  on 8th week of SO removal. 

Conclusion: Persistent IOP elevation sometimes happens after SO removal. Therefore, removing SO does not simply treat the elevated IOP happened during SO injection. Patients after SO removal should be followed up for IOP for several weeks and should be treated medically or surgically as required.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Aug 18 2019
Journal Name
Political Sciences Journal
Constitutional amendments in the era of Justice and Development Party after 2002 (reality and ambition)
...Show More Authors

Abstrct The Turkish political system has undergone exceptional and unprecedented circumstances, represented by a series of security and political unrest that has cast its shadow over the Turkish state and regional and international challenges. It has never been a pretext or pretext for continuing the comprehensive reform process. The constitutional amendments of the 1982 Constitution, Justice and development, whether political, economic or social, is not a reaction to a difficult reality; it is a system of governance and a national option stemming from within. It promotes national unity and enshrines democracy and the concept of public rights and freedoms.

View Publication Preview PDF
Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Autogenous Onlay Graft with Compression Plate for Treatment of Persistent Humeral Shaft Aseptic Non-union with Failed Previous Surgery
...Show More Authors

BACKGROUND: The humeral shaft fractures have a good rate of union, despite this fact, still there is a significant rate of nonunion after nonoperative treatment and more often after operative treatment. AIM: The aim of the study is to evaluate the autogenous onlay graft with compression plate for treatment of persistent humeral shaft non-union with failed previous surgery both radiological and functional outcome. MATERIALS AND METHODS: A prospective study on twenty patients having persistent aseptic non-union age between 20 and 60 years old, after failed surgical treatment of fractures humeral shaft in Al-Zahra teaching and Al-Kindy teaching hospitals, while infected nonunion, diabetes mellitus, secondary metastasis, smoking, a

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Activated Bentonite for Removal Nickle and Vanadium from Petroleum Distillates
...Show More Authors

The present work is to investigate the feasibility of removal vanadium (V) and nickel (Ni) from Iraqi heavy gas oil using activated bentonite. Different operating parameters such as the degree of bentonite activation, activated bentonite loading, and operating time was investigated on the effect of heavy metal removal efficiency. Experimental results of adsorption test show that Langmuir isotherm predicts well the experimental data and the maximum bentonite uptake of vanadium was 30 mg/g. The bentonite activated with 50 wt% H2SO4 shows a (75%) removal for both Ni and V. Results indicated that within approximately 5 hrs, the vanadium removal efficiencies were 33, 45, and 60% at vanadium loadings of 1

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 01 2024
Journal Name
Journal Of Ecological Engineering
Enhancing the Removal of Methyl Orange Dye by Electrocoagulation System with Nickel Foam Electrode – Optimization with Surface Response Methodology
...Show More Authors

Azo dyes like methyl orange (MO) are very toxic components due to their recalcitrant properties which makes their removal from wastewater of textile industries a significant issue. The present study aimed to study their removal by utilizing aluminum and Ni foam (NiF) as anodes besides Fe foam electrodes as cathodes in an electrocoagulation (EC) system. Primary experiments were conducted using two Al anodes, two NiF anodes, or Al-NiF anodes to predict their advantages and drawbacks. It was concluded that the Al-NiF anodes were very effective in removing MO dye without long time of treatment or Ni leaching at in the case of adopting the Al-Al or NiF-NiF anodes, respectively. The structure and surface morphology of the NiF electrode were inves

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Wed Nov 27 2024
Journal Name
International Journal Of Integrated Engineering
Noise Modeling and Removal from Electrocardiogram Signals: A Study Using Wavelet Transform with Graphical User Interface
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Wed Nov 27 2024
Journal Name
International Journal Of Integrated Engineering
Noise Modeling and Removal from Electrocardiogram Signals: A Study Using Wavelet Transform with Graphical User Interface
...Show More Authors

The electrocardiogram (ECG) is the recording of the electrical potential of the heart versus time. The analysis of ECG signals has been widely used in cardiac pathology to detect heart disease. The ECGs are non-stationary signals which are often contaminated by different types of noises from different sources. In this study, simulated noise models were proposed for the power-line interference (PLI), electromyogram (EMG) noise, base line wander (BW), white Gaussian noise (WGN) and composite noise. For suppressing noises and extracting the efficient morphology of an ECG signal, various processing techniques have been recently proposed. In this paper, wavelet transform (WT) is performed for noisy ECG signals. The graphical user interface (GUI)

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Thu Sep 08 2022
Journal Name
Al-khwarizmi Engineering Journal
Kinetics of Electrochemical Removal of Nickel using Bio-electrochemical Reactor with Packed Bed Rotating Cylinder Cathode
...Show More Authors

The kinetics of nickel removal from aqueous solutions using a bio-electrochemical reactor with a packed bed rotating cylinder cathode was investigated. The effects of applied voltage, initial nickel concentration, the rotation speed of the cathode, and pH on the reaction rate constant (k) were studied. The results showed that the cathodic deposition occurred under mass transfer control for all values of the applied voltage used in this research. Accordingly, the relationship between concentration and time can be represented by a first-order equation. The rate constant was found to be dependent on the applied voltage, initial nickel concentration, pH, and rotation speed. It was increased as the applied voltage increased and decreased as t

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Ecological Engineering
Chromium Ions Removal by Capacitive Deionization Process – Optimization of the Operating Parameters with Response Surface Methodology
...Show More Authors

An innovative desalination method called electrosorption or capacitive deionization (CDI) has significant benefits for wastewater treatment. This process is performed by using a carbon fiber electrode as a working electrode to remove hexavalent chromium ions from an aqueous solution. The pH, NaCl concentration, and cell voltage were optimized using the Box-Behnken experimental design (BDD) in response surface methodology (RSM) to study the effects and interactions of selected variables. To attain the relationship between the process variables and chromium removal, the experimental data were subjected to an analysis of variance and fitted with a quadratic model. The optimum conditions to remove Cr(VI) ions were: pH of 2, a cell voltage of 4.

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Dec 27 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Evaluation the Risk Factors that are Associated with Osteoporosis in Post Kidney Transplantation in a Sample of Iraqi Patients
...Show More Authors

Renal transplantation is a principal treatment option for end-stage kidney failure. Bone loss and fracture are serious complication of kidney transplantation, associated with morbidity and mortality. The pathogenesis of post transplantation bone loss is multifactorial and complex

View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Iraqi Journal Of Hematology
Evaluation of angiopoietin-2 level in patients with multiple myeloma at presentation and in remission state
...Show More Authors

The study aimed to assess the level of ANG‑2 in MM patients at diagnosis and in remission state and elaborate on its correlation with interleukin‑6 (IL‑6) and beta‑2 microglobulin (B2M) levels. Sixty MM patients; 20 newly diagnosed (ND), and 40 patients in remission were included. Twenty healthy individuals were included as a control group. Plasma levels of ANG‑2, B2M, and IL‑6 were tested by enzyme‑lin ked immunosorbent assay. There are significant statistical differences between ND patients and those in remission in hemoglobin, neutrophil count, blood urea, serum creatinine, glomerular filtration rate, B2M, IL6, and ANG‑2 (P = 0.001, 0.033, 0.005, 0.001, 0.001, 0.001, 0.004, and 0.001, respectively). ANG‑2 showed signifi

... Show More
View Publication
Crossref (1)
Scopus Clarivate Crossref