Preferred Language
Articles
/
jkmc-864
Comparison between Quantitative Computed Tomography and Dual-Energy X-Ray Absorptiometry in the Detection of Osteoporosis in Postmenopausal Women
...Show More Authors

Background: Osteoporosis is denoted by low bone mass and microarchitectural breakdown of bone tissue, directing to increased fracture risk and bone fragility. Fractures may lead to a decreased quality of life and increased medical costs. Thus, osteoporosis is widely considered a significant health concern.

Objective. This study aimed to compare quantitative computed tomography (QCT) and dual-energy X-Ray absorptiometry (DXA) to detect osteoporosis in postmenopausal women.

Subjects and Methods. We measured spinal volumetric bone mineral density (BMD) with QCT and areal spinal and hip BMD with DXA in 164 postmenopausal women. We calculated the osteopenia and osteoporosis detection rate for the two methods. The difference between these rates for DXA versus QCT was analyzed using the chi-square test.

Results. The detection rate of osteoporosis was 57.9% for QCT and 50.6% for DXA (significant difference, p=0.002). At the same time, the detection rate of osteopenia was 36.6% for QCT and 31.7% for DXA (significant difference, p=0.002).

Conclusions. Quantitative CT bone densitometry is an excellent tool for the evaluation of BMD. It is more sensitive than DXA for detecting osteoporosis in postmenopausal women.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 02 2011
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Correlation between Computerized Tomography Densimetry and Histomorphometry in Assessment of Bone Healing
...Show More Authors

Background: Assessment of fracture healing is a common problem in orthopedic practice and research. Computerized Tomography (CT) is a reliable tool for quantification of the fracture repair process in experimental animals. Histomorphometric evaluation provides a clear quantitative evidence of the bone healing process. The evaluation by micro-architectures in healing bone showed variable correlation between CT and histomorphometry.
Material and methods: open ulnar osteotomy induced in twenty young male rabbits under general anesthesia without internal fixation, and divided into five groups. A group of animals were sacrificed at end of 2nd week, 3rd week, 4th week, 5th week, and 6th week. The right ulna iso

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Dec 20 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Computed tomography bone density in Hounsfield units at dental implant receiving sites in different regions of the jaw bone
...Show More Authors

Background: Determination of local bone mineral density (BMD) with cortical thickness and bone height may offer a comprehensive description of the bone the surgeon will encounter when he or she actually sets the implant. Quantitative computed tomography (CT) (i.e., quantitative interpretation of values derived from Hounsfield units with a suitable calibration procedure) is the modality of choice to determine BMD. The aim of the present clinical study is to determine the local bone density in dental implant recipient sites using computerized tomography. Material and method: The sample consisted of (72) Iraqi patients whom referred to Al-Kharkh General hospital, Spiral CT scan Department for bone quality and quantity assessment after one wee

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 30 2020
Journal Name
Al-kindy College Medical Journal
Comparison between the Patterns of Common Breast Diseases Presenting as Breast Lumps in Pregnant and Non-Pregnant Married Women
...Show More Authors

Background: Breast lump is one of the most common prevalent complaint of patients attending breast clinics.

Objective: To determine if there is any change in the pattern of common breast, diseases presenting as breast lumps between pregnant and non-pregnant women among patients attending Al-Elwiya Breast Clinic.

Methods: This is a cross – sectional study, with convent's patient sampling setting in AL-Elwiya Breast Cancer Early Detection Clinic from 1st Feb. to 1st May 2018, we collected data from patients with breast lumps including the age groups, pregnancy status, parity status, previous breast diseases, hormonal drugs, menstrual cycle, breast fe

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 20 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Postoperative assessment of dental implants by using multi-slice computed tomography
...Show More Authors

Background: Implantology is a fast growing area in dentistry. One of the most common issues encountered in dental implantation procedures is the lack of adequate preoperative planning. Conventional radiography may not be able to assess the true regional three-dimensional anatomical presentation. Multi Slice Computed Tomography provides data in 3-dimentional format offering information on craniofacial anatomy for diagnosis; this technology enables the virtual placement of implant in a 3-Dimensional model of the patient jaw (dental planning). Patients, Material and Methods: The sample consisted of (72) Iraqi patients indicated for dental implant (34 male and 38 female), age range between (20-70) years old. They were examined during a time p

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 24 2022
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Initial Chest X-ray scoring in the prediction of COVID-19 patients’ outcome in the United Arab Emirates
...Show More Authors

Background: The radiological scoring of severity and progression of lung abnormalities is of great value for clinicians to define the clinical management of COVID-19 patients.

Objectives: The purpose of this study is to implement the Brixia scoring tool to assess the pattern of lung involvement in patients with COVID-19 to help predict the severity of their clinical outcome, where the clinical outcome correlates to outpatient, inpatient and/or ICU admission.

Patients and Methods: We conducted a case series study at the Sheikh Khalifa Medical City Ajman (SKMCA), United Arab Emirates from 14 March to 30 October 2020. Patients’ medical records were reviewed and followed up f

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed May 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
X-ray Data and Transition Temperature Measurements of Ca Doped Bi2Sr2La2Cu3O10+δ Superconductor
...Show More Authors

We studied the effect of Ca- doping on the properties of Bi-based superconductors by
adding differ ent amounts of CaO
to the Bi
2
Sr2La2-xCaxCu3O10+δ
compound. consequently, we
obtained three samples A,B and C with x=0.0, 0.4 and 0.8 respectively. The usual solid-state
reaction method has been applied under optimum conditions. The x-ray diffraction analy sis
showed that the samples A and B have tetragonal structures conversely the sample C has an
orthorhombic structure. In addition XRD analysis show that decreasing the c-axis lattice
constant and thus decreasing the ratio c/a for samples A,B and C resp ectively. The X-ray
florescence proved that the compositions of samples A,B and C with the ra

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 01 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The Value of the chest X-Ray for diagnosing left ventricular Dysfunction
...Show More Authors

Background: The use of the chest x-ray measurements which includes the cardiothoracic ratio(C-T) and frontal area (FA) of the heart by the CXR are useful measures for primary assessment of the cardiac dysfunction.
Patients and Methods: A Prospective study was done from the 1st of January 2005 to the 1st of October in the same year on a 120 consecutive patients who have been admitted for coronary and L.V angiogram at IBN-AL-BITAR hospital. The C-T ratio and the frontal area were measured.
Results: The study comprised 120 subjects who were admitted for coronary and L.V angiogram for diagnostic reasons. 89subjects (74.2%) are male and 31subjects (25.8%) are female .17(14%) subjects have left ventricular d

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative evaluation of the radiographic density of GuttaFlow® 2 in different obturation techniques using Spiral Computed Tomography
...Show More Authors

Background: Ideal root canal obturation depends on many factors; one of them is good sealing of root canal without pores. The aim of this study was to determine the radiographic density of GuttaFlow® 2 with different obturation techniques using spiral computed tomography. Materials and Methods: Forty palatal roots of permanent maxillary first molar were used in this study. Following working length determination, root canal was prepared using rotary PROTAPER universal system. They were randomly divided into four groups of 10 roots each, the groups are Conventional lateral condensation with Apexit Plus sealer, Conventional lateral condensation with GuttaFlow® 2 as a sealer, Soft Core Regular with GuttaFlow® 2 as a sealer and singl

... Show More
View Publication
Crossref
Publication Date
Sun Oct 27 2019
Journal Name
Iraqi Journal Of Science
Determination of Radiation Dose from Routine X-ray Examination at Three Selected Hospitals in AlNajaf, Iraq
...Show More Authors

People who undertaken different X-ray examinations are already exposed to ionizing radiation which causes biological effects. Therefore assessing the patient radiation dose is a prerequisite element in optimizing the X-ray practice and to avoid the unnecessary radiation dose. The aim of this research is to assess the skin radiation dose for those patients who undertaking routine X-ray examinations in selected three hospitals in Al Najaf city.

     Three X-ray units were involved in this experimental study; these were belonging to three hospitals in Al Najaf city-Iraq, namely Al-Sadder teaching hospital, Al-Hakeem general hospital and Al-Zahraa hospital. Data of exposure parameters (tube potential (kVp), tube c

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Assessment of X-Ray Effects on HF Radio Communications
...Show More Authors
Abstract<p>This study aims to determine the effect of x-ray radiation resulting from solar flares in high-frequency radio wave communications through the ionosphere and to study the radio blackout events that occur over Iraq, located within (38,28) latitude, and (38,49) longitude. Using X-ray data during strong X flares and radio wave absorption data across the D ionosphere for 10 years from 2012 to 2021. The study concluded that there were 43 events of x-flare, most of which were during years of high solar activity. All of these flares produced X-rays that caused a radio blackout, R3 and only 13 events affected Iraq.</p>
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref