Preferred Language
Articles
/
jkmc-813
Practice & Opinion of Doctors in Hospitals toward Referral System in Iraq
...Show More Authors

Background: Primary Health care (PHC) is unanimous to be the cornerstone of a person-centered health system. While the adoption of a well-function, two-way, and organized referral system is the mainstay in the development of an efficient healthcare delivery system.  

Objective: To Assess the practice & opinion of doctors in the hospitals toward the referral system.  to determine the doctors in the hospital's commitment to referral system instructions and guidelines.

Subjects and Methods: A cross-sectional study with analytic elements was conducted in nine Iraqi governorates. Eight doctors from each health directorate, resulting in a total of 72 doctors using a specially designed questionnaire. Statistical analysis was done by using SPSS, the P≤0.05 was considered statistically significant.

Results: of the total 72 physicians, 31(43.1%) aged 40-49years, 48(66.7%) were males, and 58(80.6%) were specialists., 58 doctors (80.6%) had no coordination with the PHC-doctors, the same percentage considered the current referral system is ineffective. PHC patients-crowded, doctors-shortage were the causes of inadequately filling PHC-part of the referral form. And PHC-hospital doctors-coordination had a significant association with their age, gender, and their thinking about adequate filling.

Conclusion: despite the importance of the referral system, half of the doctors disagreed about the current referral system’s effectiveness; & most of them had no coordination with the PHC-doctors. PHC crowded/doctors’ shortage the main causes of inadequate filling PHC part of referral-form.

 

 

 

الملخص:

الخلفية: تعتبر الرعاية الصحية الأولية بالإجماع حجر الزاوية في نظام صحي يركز على المريض. في حين أن اعتماد نظام إحالة جيد ثنائي الاتجاه ومنظم هو الدعامة الأساسية في تطوير نظام فعال لتقديم الرعاية الصحية.

الهدف: تقييم ممارسة ورأي الأطباء في المستشفيات تجاه نظام الإحالة. كذلك لتحديد مدى التزام الأطباء في المستشفى بتعليمات وإرشادات نظام الإحالة.

طريقة البحث: أجريت دراسة مقطعية مع عناصر تحليلية في تسع محافظات عراقية. ثمانية أطباء من كل مديرية صحية ، مما أدى إلى ااشتراك 72 طبيبًا في استبيان مصمم خصيصًا للبحث. تم إجراء التحليل الإحصائي باستخدام SPSS ، واعتبر P≤0.05 ذو دلالة إحصائية.

النتائج: من إجمالي 72 طبيبًا ، 31 (43.1٪) تتراوح أعمارهم بين 40-49 عامًا ، 48 (66.7٪) من الذكورو 58 (80.6٪) من المتخصصين. ، 58 (80.6٪) منهم ليس لديهم اي تنسيق مع أطباء الرعاية الصحية الأولية. و بنفس النسبة يعتبرون نظام الإحالة الحالي غير فعال. ازدحام المرضى في المراكز ونقص الأطباء هي اهم أسباب نقص ملأ نموذج الإحالة الخاص باطباءالمراكز الصحية بشكل مناسب. وكان لتنسيق أطباء مستشفى الرعاية الصحية الأولية علاقة كبيرة مع العمر والجنس وتفكيرهم في الملأ االنموذجي.

الخلاصة: بالرغم من أهمية نظام الإحالة ، اختلف نصف الأطباء حول فعالية نظام الإحالة الحالي. ومعظمهم ليس لديهم اي تنسيق مع أطباء المراكز الصحية. ازدحام الرعاية الصحية الأولية / نقص الأطباء اهم الأسباب الرئيسية لضعف ملأ نموذج الإحالة.

 

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Calculate the one – expectation to electronic charge of atomic system contiun two electron
...Show More Authors

The aim of this work is to calculate the one- electron expectation value of the electronic charge of atomic system Z=2,3….7 and we compare with He atom . the electronic density function D(r1) of He atom and like ions are evaluated . using Hartree –Fock wave.

View Publication Preview PDF
Crossref
Publication Date
Sat Feb 05 2011
Journal Name
International Journal Of Chemical Reactor Engineering
Mass Transport Properties of a Flow-Through Electrolytic Reactor Using Zinc Reduction System
...Show More Authors

An electrolytic process for the removal of Zn(II) from aqueous solution using a parallel amalgamated copper screens cathode operated in the flow through mode is proposed. The current-potential curves recorded at a rotating amalgamated copper disc electrode were used to determine diffusion coefficient of Zn(II). The performance of electrolytic reactor was investigated by using different flow rates at initial zinc ion concentration(48 mg/L). Taking into account the residential Zn(II) concentration, the best results were obtained for cathode potential of (-1.35 V vs. SCE) at flow rate (320 L/h). Zinc ion concentration was found to decrease from 48 mg/L to 1 mg/L during 120 min. of electrolysis. The experimental data are well correlate

... Show More
View Publication
Crossref
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Evaluation of Transfected HEP-2 Cell Line Using ß-Galactosidase Reporter Assay System
...Show More Authors

Liposome-mediated transfection of cancer cells provide a valuable experimental technique to study cellular gene expression and may also be adapted for gene therapy studies. However, the widely recognized advantage of liposome-mediated transfection is high efficiency. Therefore, this study were performed to optimize transfection techniques in human larynx carcinoma cell line Hep-2 using the commercial synthetic lipid TransFast™ Reagent and monitoring the expression efficiency by using the pSV-?-galactosidase Control Vector which encoded ?-galactosidase, maximum transfection efficiency were achieved with TransFast™ Reagent used at the Charge ratios of 2:1 and 0.5 µg DNA/ml, this is indicate that TransFast™ Reagent can be used as an eff

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 31 2017
Journal Name
Journal Of Engineering
Design and Implementation of Classical Sliding Mode Controller for Ball and Plate System
...Show More Authors

Ball and Plate (B&P) system is a benchmark system in the control engineering field that has been used to verify many control methods. In this paper the design of a sliding mode . controller has been investigated and verified in real-time via implementation on a real ball and plate system hardware. The mathematical model has been derived and the necessary parameters have been measured. The sliding mode controller has been designed based on the obtained mathematical model. The resulting controller has been implemented using the Arduino Mega 2560 and a ball and plate system built completely from scratch. The Arduino has been programmed by the Arduino support target for Simulink. Three test signals has been used for verification purposes

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 25 2021
Journal Name
Engineering And Technology Journal
Performance evaluation of Photovoltaic Panels by a Proposed Automated System Based on Microcontrollers
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
DESIGN OF A CONTINUOUS SLIDING MODE CONTROLLER FOR THE ELECTRONIC THROTTLE VALVE SYSTEM
...Show More Authors

Lowering the emission, fuel economy and torque management are the essential
requirements in the recent development in the automobile industry. The main engine control
input that satisfies the above requirements is the throttling angle which adjusts the air mass
flow rate to the engine port. Due to the uncertainty and the presence of the nonlinear
components in its dynamical model, the sliding mode control theory is utilized in this work
for the throttle valve angle control system to design a robust controller for this system in the
presence of a nonlinear spring and Coulomb friction. A continuous sliding mode control law
which consists of a saturation function, instead of a signum function, and the integral of
ano

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Engineering
Tuning of PID Controllers for Quadcopter System using Cultural Exchange Imperialist Competitive Algorithm
...Show More Authors

Quadrotors are coming up as an attractive platform for unmanned aerial vehicle (UAV) research, due to the simplicity of their structure and maintenance, their ability to hover, and their vertical take-off and landing (VTOL) capability. With the vast advancements in small-size sensors, actuators, and processors, researchers are now focusing on developing mini UAV’s to be used in both research and commercial applications. This work presents a detailed mathematical nonlinear dynamic model of the quadrotor which is formulated using the Newton-Euler method. Although the quadrotor is a 6 DOF under-actuated system, the derived rotational subsystem is fully actuated, while the translational subsystem is under-actuated. The der

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Southwest Jiaotong University
A Recognition System for Subjects' Signature Using the Spatial Distribution of Signature Body
...Show More Authors

This investigation proposed an identification system of offline signature by utilizing rotation compensation depending on the features that were saved in the database. The proposed system contains five principle stages, they are: (1) data acquisition, (2) signature data file loading, (3) signature preprocessing, (4) feature extraction, and (5) feature matching. The feature extraction includes determination of the center point coordinates, and the angle for rotation compensation (θ), implementation of rotation compensation, determination of discriminating features and statistical condition. During this work seven essential collections of features are utilized to acquire the characteristics: (i) density (D), (ii) average (A), (iii) s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jan 14 2018
Journal Name
Journal Of Engineering
Optimum Design of Power System Stabilizer based on Improved Ant Colony Optimization Algorithm
...Show More Authors

This paper presents an improved technique on Ant Colony Optimization (ACO) algorithm. The procedure is applied on Single Machine with Infinite Bus (SMIB) system with power system stabilizer (PSS) at three different loading regimes. The simulations are made by using MATLAB software. The results show that by using Improved Ant Colony Optimization (IACO) the system will give better performance with less number of iterations as it compared with a previous modification on ACO. In addition, the probability of selecting the arc depends on the best ant performance and the evaporation rate.

 

View Publication Preview PDF
Publication Date
Wed Apr 05 2023
Journal Name
Journal Of Engineering
Performance Evaluation of Small Scale Air-Conditioning System Using R22 and Alternative Refrigerants
...Show More Authors

A mathematical model has been formulated to predict the influence of high outdoor air temperature on the performance of small scale air - conditioning system using R22 and alternative refrigerants R290, R407C, R410A. All refrigerants were investigated in the cooling mode operation. The mathematical model results have been validated with experimental data extracted from split type air conditioner of 2 TR capacity. This entailed the construction of an experimental test rig which consists of four main parts. They are, the refrigeration system, psychrometric test facility, measuring instrumentation, and auxiliary systems. The conditioned air was maintained at 25 0C dry bulb and 19 0C wet bulb for all tests. The outdoor ambient air temperatur

... Show More
View Publication Preview PDF
Crossref (3)
Crossref