Comparative study on Various Tube Voltages and Contrast Media Doses in CT Pulmonary Angiography to detect Pulmonary Thromboembolism
...Show More Authors

Background: Lowering the amount of iodinated contrast material and tube voltage may increase pulmonary artery opacification and thrombus identification without compromising picture quality.

Objectives: To explore the efficiency of using lower tube voltage and a lower contrast medium dose for conducting computed tomography for pulmonary angiography (CTPA) aiming to increase its accuracy in detecting pulmonary thromboembolism (PTE).

Subjects and Methods:100 patients scheduled for CTPA with a preoperative diagnosis of PTE were grouped into two: group A, (50 patients) got 1 mL/kg at 120 kV and group B, (50 patients) received 0.5 mL/kg at 80 kV.The technique of bolus tracking was implemented.Values of midpoint of multiple pulmonary artery divisions were used to assess attenuation.Significant values are those that exceed 300 Hounsfield units (HU). The dosage of radiation received by the patient, defined as the effective dose, was compared between groups.

Results: Total mean attenuationdata for the pulmonary arteries have shown to be substantially greater in group-B compared to group-A (39110.4HU vs. 335.97.9HU, P=0.001). Moreover, total dose length product (DLP) values were substantially lower in group-B (934.9 mGy.cm vs. 384.443 mGy.cm, P=0.001). While effective dose values have shown to be significantly lower in group-B (2.90.3 mSv vs. 13.21.8 mSv, P 0.001).

Conclusion: Low-kilovoltage technique and low quantity of iodinated contrast are useful in conducting (CTPA) with high accuracy in detection of pulmonary thromboembolism.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 18 2025
Journal Name
International Journal Of Scientific Research In Science, Engineering And Technology
A Comprehensive Review on Cryptography Algorithms: Methods and Comparative Analysis
...Show More Authors

The evolution of cryptography has been crucial to preservation subtle information in the digital age. From early cipher algorithms implemented in earliest societies to recent cryptography methods, cryptography has developed alongside developments in computing field. The growing in cyber threats and the increase of comprehensive digital communications have highlighted the significance of selecting effective and robust cryptographic techniques. This article reviews various cryptography algorithms, containing symmetric key and asymmetric key cryptography, via evaluating them according to security asset, complexity, and execution speed. The main outcomes demonstrate the growing trust on elliptic curve cryptography outstanding its capabi

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Wed Jun 01 2011
Journal Name
Journal Of The College Of Basic Education
A Proposed Steganographic Method in Digital Media
...Show More Authors

WA Shukur, journal of the college of basic education, 2011 The aim of this research is designing and implementing proposed steganographic method. The proposed steganographic method don’t use a specific type of digital media as a cover but it can use all types of digital media such as audio, all types of images, video and all types of files as a cover with the same of security, accuracy and quality of original data, considering that the size of embedded data must be smaller than the size of a cover. The proposed steganographic method hides embedded data at digital media without any changing and affecting the quality of the cover data. This means, the difference rate between cover before hiding operation and stego is zero. The proposed steg

... Show More
View Publication
Publication Date
Sun Mar 06 2022
Journal Name
Al–bahith Al–a'alami
DEPENDENCE OF MEDIA OFFICES ON THE CABINET'S WEBSITE AS A SOURCE OF INFORMATION
...Show More Authors

     The research aimed to identify the extent to which the media offices in the ministries depend on the website of the Iraqi Council of Ministers as a source of information. Such goal includes a set of sub-goals: Knowing the reasons for media offices' reliance on the information provided by the Cabinet's website; and revealing the benefit derived from relying on the Cabinet's website.

The researcher used the survey method to screen and comprehend the extent to which the media offices in the ministries depend on the website of the Iraqi Council of Ministers as a source of information.

The mechanism of comprehensive account of the limits of research wa

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 06 2001
Journal Name
مجلة العلوم الاقتصادية والادارية
Double cross-over and cross-over with extra period designs -comparative study-
...Show More Authors

The goal of the research is to find the optimization in the test of the appropriate cross-over design for the experiment that the researcher is carrying out (under assumption that there are carry-over effects of the treatments) to posterior periods after the application period (which is often assumed to be the first period). The comparison between the double cross-over design and the cross-over design with extra period. The similarities and differences between the two designs were studied by measuring the Relative Efficiency (RE) of the experiment.

Preview PDF
Publication Date
Wed Aug 02 2023
Journal Name
Bionatura
Comparative Study of IgG Between Iraqi Covid-19 Patients and Vaccinated Individuals
...Show More Authors

COVID-19 is a coronavirus disease caused by the severe acute respiratory syndrome. According to the World Health Organization (WHO), coronavirus-2 (SARS-CoV-2) was responsible for 87,747,940 recorded infections and 1,891,352 confirmed deaths as of January 9, 2021. Antibodies that target the Sprotein are efficient in neutralizing the virus. Methodology: 180 samples were collected from clinical sources (Blood and Nasopharyngeal swabs) and from different ages and genders at diverse hospitals in Baghdad / IRAQ between November 5, 2021, to January 20, 2022. All samples were confirmed infected with COVID-19 disease by RT-PCR technique. Haematology analysis and blood group were done for all samples, and Enzyme-Linked Immunosorbent Assay used an Ig

... Show More
Scopus
Publication Date
Sun Oct 04 2026
Journal Name
Alrafidain Of Law
The Effects of the research and technology development contract -A comparative study-
...Show More Authors

Researching the effects of the research and technological development contract, determining its extent and demarcating the boundaries of the obligations imposed in it, is the cornerstone of economic growth and development, because defining these obligations removes the ambiguity and conflict between interests, by stating the rights owed to each party and even trying to reconcile them, or impose protection by specifying guarantees that are compatible with the essence of the R&D contract, For the purpose of studying the subject thoroughly, we will divide this research into two sections. The first is devoted to identifying the parties to the research and technological development contract. As for the other topic, we will explain the obligation

... Show More
View Publication
Publication Date
Thu Dec 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Comparative Study of New Re-Ni-Mo/Al2o3 and Conventional Hydrodesulphurization Catalyst
...Show More Authors

New types of hydrodesulfurization (HDS) catalyst Re-Ni-Mo/ γ-Al2O3 was prepared and tested separately with two prepared conventional HDS catalysts (Ni-Mo/ γ-Al2O3 and Co-Mo//γ-Al2O3) by using a pilot plant hydrotreatment unit. Activities of three prepared hydrodesulfurization catalysts were examined in hydrodesulfurization (HDS) of atmospheric gas oil at different temperatures 275 to 350 °C and LHSV 1 to 4 h-1, the reactions conducted under constant pressure 40 bar and H2/HC ratio 500 ml/ml .Moreover, the hydrogenation of aromatic (HAD) in gas oil has been studied. HDS was much improved by adding promoter Re to the Ni-Mo/Al2O3

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Comparative Study of New Re-Ni-Mo/Al2o3 and Conventional Hydrodesulphurization Catalyst
...Show More Authors

New types of hydrodesulfurization (HDS) catalyst Re-Ni-Mo/ γ-Al2O3 was prepared and tested separately with two prepared conventional HDS catalysts (Ni-Mo/ γ-Al2O3 and Co-Mo//γ-Al2O3) by using a pilot plant hydrotreatment unit. Activities of three prepared hydrodesulfurization catalysts were examined in hydrodesulfurization (HDS) of atmospheric gas oil at different temperatures 275 to 350 °C and LHSV 1 to 4 h-1, the reactions conducted under constant pressure 40 bar and H2/HC ratio 500 ml/ml .Moreover, the hydrogenation of aromatic (HAD) in gas oil has been studied. HDS was much improved by adding promoter Re to the Ni-Mo/Al2O3 catalyst. The results showed that Re-Ni-Mo/ γ-Al2O3 have more activity in desulfurization than Ni-Mo//γ-Al2O3

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 01 2007
Journal Name
Al-khwarizmi Engineering Journal
An experimental comparative study between polypropylene and laminated lower limb prosthetic socket
...Show More Authors

Most researchers concentrate their studies on the design, stress and pressure distributions of the prosthetic socket. A little attention is considered for the stiffness of the various materials of the prosthetic sockets. Prosthetic laminated sockets in Iraq are costly to be manufactured while polypropylene socket is relatively cheap in comparing with the laminates.

Experimental study is conducted to compare the stiffness of five prosthetic sockets made of different materials. Compression, three point flexural and tensile tests are implemented by the Testometric machine. The laminate sockets give better results in compression than polypropylene. Polypropylene gives good results in bending compared with the laminate sockets. When t

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Comparative Study of New Re-Ni-Mo/Al2o3 and Conventional Hydrodesulphurization Catalyst
...Show More Authors

New types of hydrodesulfurization (HDS) catalyst Re-Ni-Mo/ γ-Al2O3 was prepared and tested separately with two prepared conventional HDS catalysts (Ni-Mo/ γ-Al2O3 and Co-Mo//γ-Al2O3) by using a pilot plant hydrotreatment unit. Activities of three prepared hydrodesulfurization catalysts were examined in hydrodesulfurization (HDS) of atmospheric gas oil at different temperatures 275 to 350 °C and LHSV 1 to 4 h-1, the reactions conducted under constant pressure 40 bar and H2/HC ratio 500 ml/ml .Moreover, the hydrogenation of aromatic (HAD) in gas oil has been studied. HDS was much improved by adding promoter Re to the Ni-Mo/Al2O3 catalyst. The results showed that Re-Ni-Mo/ γ-Al2O3 have more activity in desulfurization than Ni-Mo//

... Show More
View Publication
Crossref (1)
Crossref