Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Apr 15 2021
Journal Name
Biochem. Cell. Arch.
CYTOKINES SERUM PROFILE IMMUNOSUPPRESSANT BALB/C MICE INFECTED WITH CRYPTOSPORIDIUM PARVUM
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing the Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Bionatura
Chronic Myeloid Leukemia: A retrospective study of clinical and pathological features
...Show More Authors

Chronic myeloid leukemia (CML), is one of the myeloproliferative disorders with a characteristic cytogenetic abnormality resulting in the BCR-ABL fusion gene. Imatinib Mesylate is an effective agent for treating patients in all stages of CML. According to the annual Iraqi cancer registry 2019, the total number of chronic myeloproliferative disorders was 338. The percentage and incidence rates were 0.94% and 0.86%, respectively, with a higher incidence rate in males than females (1.12 in males and 0.60 in females). In this registry, no details about CML, so this study aimed to estimate the number of CML patients who attended the national center of hematology from 2005 until 2020 and investigate their epidemiological and clinic-pathol

... Show More
View Publication
Scopus (23)
Crossref (5)
Scopus Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Clinical Evaluation of Orphenadrine citrate as a Plain Tablet
...Show More Authors

Orphenadrine is an anticholinergic ,antimuscarinic , centrally acting skeletal muscle relaxant .It presents in the form of citrate and HCl salts which are used in treatment of the symptoms of mild Parkinson's disease and also it is used as adjuvant with other drugs in the therapy .

      Many trials were made to formulate Orphenadrine citrate as a plain tablet using wet granulation or direct compression technique in order to get a satisfactory formula through studying the effect of various factors such as binders , diluents and disintegrants types .

    The best formula was obtained by using Poly Vinyl Pyrolidine (PVP) as a binder also the results indicated that starch and mannitol

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Efficiency and Safety of Desferioxamine Chelation Therapy in Paediatric Patients with Transfusion-Dependent Anaemia: Experience of two Centres from Sudan
...Show More Authors

Background: Repeated blood transfusion   is   the main   therapeutic option for transfusion-dependent anaemias with consequent iron overload and organ damage .Therefore iron chelating agents are important protective measures for these patients. The aim of this study was  to investigate  the efficiency and safety of Desferroxamine  in paediatrics population subjected  to iron overload as a consequence  of repeated transfusion in a group of  Sudanese children  

Subjects & Methods: This was a descriptive cross-sectional hospital based study.  Conducted in two main paediatric reference hospitals   in, Su

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Aug 29 2018
Journal Name
Biomedical And Pharmacology Journal
Comparison of Some Mechanical and Physical Properties of three Types of Impression Materials with Different Dental Implant Angulations
...Show More Authors

Choosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Physics: Conference Series
Evaluation of Nuclear safety procedures in some Iraqi universities
...Show More Authors

View Publication
Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Treatment of localized vitiligo with 1% pimecrolimus Cream versus 0.05% clobetasol propionate cream—single, blinded, comparative therapeutic trial
...Show More Authors

KE Sharquie, HR Al-Hamamy, AA Noaimi, KA Ali, Journal of Cosmetics, Dermatological Sciences and Applications, 2015 - Cited by 3

View Publication
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
The Surgical outcomes of fundus-first technique in lowering the rate of bile duct injuries and bleeding during open cholecystectomy that facing intraoperative difficulties: A single-center prospective study: The surgical outcomes of open fundus-first cholecystectomy technique.
...Show More Authors

Background: The problem of difficult gallbladder is not clearly defined and associated with real missing of therapeutic approaches that decreased morbidity. Moreover, the difficult gallbladder was reported as a contributing risk factor for biliary injury due to raised difficulty in surgical dissection within Calot’s triangle. The aim of this study is to determine the surgical outcomes of the open fundus-first cholecystectomy in lowering the rate of lethal intraoperative risks.

Subjects and Methods: Our prospective study conducted during the period of January 2019 to December 2022 at Ibn Sina specialized hospital, Khartoum, Sudan, for two hundred and fifty-three patients underw

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref