Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Annals Of R.s.c.b.
Assessment of Women’s Knowledge about Cesarean Section at Maternity and Pediatric Hospital in AL-Samawa City
...Show More Authors

Objectives: 1. Assessment women’s knowledge about caesarean section. 2. Determining women’s knowledge in relation to their demographic characteristics (age, level of education, and economic status). Methodology: A descriptive design was conducted on Assessment Women’ Knowledge about Cesarean Section at Maternity and Pediatric Hospital in AL-Samawa City. This study started from 26th of September 2020 up to 16th March 2021. Sample of (100) married women who were at reproductive age, pregnant (prime or multipara ) who were planned to have birth by elective cesarean section or had previous elective caesarian section without medical indication or women who had cesarean section with medical indication or emergency. Results: Results

... Show More
Preview PDF
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Three-Dimensional Microfabrication With Conjugated Polymers
...Show More Authors

In this paper we reported the microfabrication of three-dimensional structures using two-photon polymerization (2PP) in a mixture of MEH-PPV and an acrylic resin. Femtosecond laser operating at 800nm was employed for the two-photon polymerization processes. As a first step in this project we obtained the better composition in order to fabricate microstructers of MEH-PPV in the resin via two-photon polymerzation. Acknowledgement:This research is support by Mazur Group, Harvrad Universirt.

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Human Sport And Exercise - 2019 - Spring Conferences Of Sports Science
The effect of special force training on the development of biomechanical variables for running raising awareness during the performance on the jumping table
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Thu Aug 04 2022
Journal Name
Contemporary Nurse
ICU nurses’ safety performance related to respect for safety and management commitment: A cross-sectional study
...Show More Authors

View Publication
Scopus (16)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Thu Mar 29 2018
Journal Name
Construction Research Congress 2018
Validation of Time-Safety Influence Curve Using Empirical Safety and Injury Data—Poisson Regression
...Show More Authors

View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Tue May 24 2022
Journal Name
International Journal Of Occupational Safety And Ergonomics
Contributions of safety critical success factors and safety program elements to overall project success
...Show More Authors

View Publication
Scopus (27)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Tue Aug 16 2016
Journal Name
Case Studies In Surgery
Ameloblastoma: A clinical study of 25 Iraqi patients
...Show More Authors

Objective: Geographic differences in clinical and pathological aspects of ameloblastoma have been suggested, therefore the purpose of this study was to analyze cases of ameloblastoma in terms of clinical and radiographic manifestations, histopathological types, treatment modalities and recurrence rate and compare them with reports from other parts of the world. Methods: The medical reports of patients diagnosed with ameloblastoma were reviewed and the data concerning the age, gender, chief complaint, the anatomical site of the lesion, radiographic appearance, histopathological diagnosis, treatment approach and recurrence were retrieved. Surgical treatment consisted of either enucleation with curettage and peripheral ostectomy or resection;

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 25 2022
Journal Name
International Journal Of Drug Delivery Technology
Expression of Urotensin II of Human Placental Tissues and in Serum in Gestational Diabetic Mellitus in Iraqi Woman
...Show More Authors

The placenta is an organ between the mother and fetus necessary for fetal growth and development. Gestational diabetes mellitus (DM) is the most frequent metabolic condition detected during pregnancy. It is characterized as hyperglycemia of various severity with onset or first detection during pregnancy that does not clearly describe any form of preexisting diabetes. Urotensin II (UII), a pluripotent vasoactive peptide, is important in developing insulin resistance. This study aimed to determine the level of Urotensin II(UII) in placenta and in the serum of diabetic and nondiabetic women. Methods The blood and placenta tissue collected from 50 ladies had been enrolled in this research ( 25 females with uncomplicated), (25 women with gestati

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Estimation of cellular immune response by evaluation of some cytokines in immunopathogenesis of chronic hepatitis B and C pre- and post- treated Iraqi patients (in vivo and in vitro)
...Show More Authors

Two groups of chronic hepatitis B and C virus patients were divided into Pre-treated patients (25 CHB patients with positive HBs Ag for more than 6 months and 40 CHC patients), and post-treated patients [12 CHB patients (4, 6, and 2 were treated with lamivudine, IFN-? and combination of LMV + IFN-? respectively), and 27 patients for CHC (3, 13 and 11 patients were treated with Ribavirin, IFN-? and combination therapy (RBV+ IFN-?) respectively].These patients were followed up for 6 months. By using ELISA technique, levels of IL-6, IL-10, IFN-? and TNF-? were measured in vivo and in vitro (supernatant of PBMCs stimulated with PHA) and compared with healthy control. The mean level of IL-6, IL-10 and TNF-? in CHB patients showed significant dif

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 25 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative study of retention of fiber-reinforced post at middle and cervical one thirds of root canal cemented by polycarboxylate and zinc phosphate cements measured at different storage times
...Show More Authors

Background: The purpose of this study was to compare regional bond strength at middle and cervical thirds of the root canal among glass fiber-reinforced composite (FRC) endodontic posts cemented with different cements, using the push-out test to compare the performance (retention) of two types of luting cements; polycarboxylate cement and Zinc phosphate cement used to cement translucent fiber post and to compare the result of the push-out test at different storage times;1 week ,1month and 2 months. Materials and methods: Ninety caries-free, recently extracted single-rooted human teeth with straight root canals was used in this study, The root canals were endodontically instrumented at a working length of 0.5 mm from the apex by m

... Show More
View Publication Preview PDF