Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
Copolymerazaion of N-vinyl-2-pyrrolidon with Acrylic Acid and Methylmethacrylate
...Show More Authors

Low conversion copolymerization of N-vinyl-2-pyrrolidon M.W = (111.14) VP (monomer-1) has been conducted with acrylic acid AA and methymethacrylate MMA in ethanol at 70ºC , using Benzoyl peroxide BPO as initiator . The copolymer composition has been determined by elemental analysis. The monomer reactivity ratios have been calculated by the Kelen-Tudos and Finman-Ross graphical procedures . The derived reactivity ratios (r1 , r2 ) are : (0.51 , 4.85) for (VP / AA ) systems and (0.34 , 7.58) for (VP , MMA) systems , and found the reactivity ratios of the monomer AA , MMA is mor than the monomer VP in the copolymerization of (VP / AA) and (VP /MMA) systems respectly . The reactivity ratios values were used for microstructures calculation.

View Publication Preview PDF
Crossref
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Integrated Approach for Management OF Supply chain and relationship with MRP
...Show More Authors

 

Find interested in the harmonization of variables and determinants of supply chain planning needs of the material, leading to the results start effective supply chain management, and end up quickly modify the sizes to suit the demand and turnover in the market. As well as identifying relationships between variables, and type of relationship used by the company with the processors and their feasibility, and indicate the level of interest and willingness to redesign the supply chain Company for Electrical Industries and build an integrated model for supply chain with the MRP system can be applied in the company.

Research depend on quantitative and descriptive method, It

... Show More
View Publication
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Responsivity of porous silicon for blue visible light with high sensitivity
...Show More Authors

In this work, porous silicon (PS) are fabricated using electrochemical etching (ECE) process for p-type crystalline silicon (c-Si) wafers of (100) orientation. The structural, morphological and electrical properties of PS synthesized at etching current density of (10, 20, 30) mA/cm2 at constant etching time 10 min are studied. From X-ray diffraction (XRD) measurement, the value of FWHM is in general decreases with increasing current density for p-type porous silicon (p-PS). Atomic force microscope (AFM) showed that for p-PS the average pore diameter decreases at 20 mA. Porous silicon which formed on silicon will be a junction so I-V characteristics have been studied in the dark to calculate ideality factor (n), and saturation current (Is

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jul 01 2022
Journal Name
The Egyptian Journal Of Hospital Medicine
Evaluation of Adipokines Among Children Infected with Some Protozoan Intestinal Parasites
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Wed Mar 20 2024
Journal Name
Biomedical And Pharmacology Journal
Uropathogenic Infection Associated with Prostate Hypertrophy and Transurethral Resection of Prostate
...Show More Authors

Benign prostatic hyperplasia (BPH) is a prevalent condition among elderly and middle-aged men characterized by symptoms such as dysuria, urinary incontinence, and frequent micturition. The gold standard procedure for relieving BPH symptoms is transurethral resection of the prostate (TURP). However, some patients undergoing TURP are at risk of developing urinary tract infections (UTIs) due to uropathogenic bacteria. This prospective study aimed to investigate post TURP bacteruria alongside with multifactoria risk factors that implicated postoperatively compared to preoperative and intraoperative periods. Ninety patients undergoing TURP and 30 control subjects were included in the study. Urine specimen for urine analysis from pateints

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Dec 29 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Syntesis and Characterization of Complexes Anthranilic Acid With Some Metal Ions
...Show More Authors

The  research includes attempts to prepare anthranil ic acid (C7H7N02) complexes  with some metals: [Pd (II), Fe(ll), and  Fe (Ill))  which have been characterized by using:

Thermal stability (melti ng point, d composition poit), molar conductivity, IR,   UV-visible   spectra,   elemental   analysis   (C-H-N)   and   magnetic properties.  The   general  formula   has   been  given for  the   prepared complexes:-

- M(C2H6N02)2 Where M= [Pd(ll), Fe(TI), Hg(ll)]

 

:.. M(C1H6N02)l Where  M= [Fe(llf)]

View Publication Preview PDF
Publication Date
Sat Nov 28 2020
Journal Name
Iraqi Journal Of Science
Survey Based Study: Classification of Patients with Alzheimer’s Disease
...Show More Authors

 Neuroimaging is a description, whether in two-dimensions (2D) or three-dimensions (3D), of the structure and functions of the brain. Neuroimaging provides a valuable diagnostic tool, in which a limited approach is used to create images of the focal sensory system by medicine professionals. For the clinical diagnosis of patients with Alzheimer's Disease (AD) or Mild Cognitive Impairs (MCI), the accurate identification of patients from normal control persons (NCs) is critical. Recently, numerous researches have been undertaken on the identification of AD based on neuroimaging data, including images with radiographs and algorithms for master learning. In the previous decade, these techniques were also used slowly to differentiate AD a

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Skin Scar Using CO2 Laser with or Without Corticosteroid
...Show More Authors

CO2 Laser (10600nm) is the recent method in the management of challenging skin scar resulting from trauma, burn and surgical wound. The aim of this study was to evaluate the efficacy & safety of fractional CO2 laser (10600nm) in treatment of skin scar. Materials and Methods:Twenty patients with different types of scars treated with fractional CO2 (10600nm) laser, (10 patients) were given additional intralesional Triamcinolone. Results: All of the twenty patients included in this study showed some sort of improvements in scar texture, height and pliability and all of the ten patients who received intralesional Triamcinolone after laser show complete satisfaction. Conclusion:Fractional CO2 (10600nm) laser can be used as alternative, ef

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 16 2015
Journal Name
Journal Of The College Of Basic Education
Formation of self-assembled polymeric complexes with bridged azido-dicarboxylato ligands
...Show More Authors

In this publication, several six coordinate bridged-polymeric metal complexes are reported. The reaction of 4,4`-dipyridine with ethyl chloroacetate in mole ratio of 1:2 gave the multidentate carboxylate ligand bis(N-carboxylatomethyl)-4,4`-dipyridinium). The reaction of the ligand with metal chloride and sodium azide resulted in the formation of the required polymeric complexes. Upon complex formation, the carboxylato ligand behaves as a neutral multidantate species. The mode of bonding and overall geometry of the complexes were determined through physicochemical and spectroscopic methods. These studies revealed octahedral geometry about metal centres and complexes of the general formula [Cr2(L)(N3)4]Cl2.H2O, Na2[Ag2(L)(N3)4].H2O and [M2(L

... Show More
Publication Date
Tue Jan 18 2022
Journal Name
Iraqi Journal Of Science
Contrast Enhancement of the Mammographic Image Using Retinex with CLAHE methods
...Show More Authors

Recently digital mammography is most widely used technology for early detection of breast cancer. The main diagnosing elements such as lesion or masses in digital mammograms are with law contrast. The purpose of this paper is to enhance the mammogram images by increasing its contrast. Different enhancement method are used for this purpose such as histogram equalization (HE), Contrast Limited Adaptive Histogram Equalization (CLAHE), Morphological, and Retinex. The Retinex method also implement by combining it with HE once, and with CLAHE to improve its performance. The experimental results show that using Retinex with CLAHE can produce an image with enhancement in contrast better than using it with HE method and better than other methods

... Show More
View Publication Preview PDF